34.81.7.005.9024 FINDER, 34.81.7.005.9024 Datasheet - Page 4

SSR, 2A, 5VDC

34.81.7.005.9024

Manufacturer Part Number
34.81.7.005.9024
Description
SSR, 2A, 5VDC
Manufacturer
FINDER
Datasheet

Specifications of 34.81.7.005.9024

Control Voltage Type
DC
Input Voltage
3.5VDC To 12VDC
Load Current
2A
Load Voltage Range
1.5Vdc To 24Vdc
Svhc
No SVHC (15-Dec-2010)
Approval Bodies
ANCE, GOST
Approval Category
UL Recognised
Contact
RoHS Compliant
Contact Configuration
SPST-NO
Relay Terminals
Through Hole
Rohs Compliant
Yes
F 34 - Electrical life (AC) v contact current
DC coil data
Coil specifications
Technical data
Contact specification
4
Insulation according to EN 61810-1:2004
Nominal voltage of supply system
Rated insulation voltage
Pollution degree
Insulation between coil and contact set
Insulation between open contacts
Conducted disturbance immunity
Burst (5...50)ns, 5 kHz, on A1 - A2
Surge (1.2/50 µs) on A1 - A2 (differential mode)
Other data
Bounce time: NO/NC
Vibration resistance (5…55)Hz: NO/NC
Shock resistance
Power lost to the environment
Recommended distance between relays mounted on PCB
Nominal
voltage
Type of insulation
Overvoltage category
Rated impulse voltage
Dielectric strength
Type of disconnection
Dielectric strength
U
12
24
48
60
V
N
5
7.005
7.012
7.024
7.048
7.060
code
Coil
Operating range
16.8
33.6
42
U
3.5
8.4
V
min
Resistive load - cosϕ = 1
Inductive load - cosϕ = 0.4
U
18
36
72
90
max
V
without contact current
with rated current
7.5
Resistance Rated coil
12,300
19,700
V AC/kV (1.2/50 µs) 1,000/1.5
3,350
R
130
840
Electromechanical relay
kV (1.2/50 µs) 6
consumption
I at U
mA
38.4
14.2
7.1
3.9
3
V AC 230/400
V AC 250
V AC 4,000
N
mm ≥ 5
ms 1/6
W 0.2
W 0.5
g 10/5
g 20/14
3
Reinforced
III
Micro-disconnection
EN 61000-4-4
EN 61000-4-5
• When switching a resistive load (DC1) having voltage and current
• In the case of DC13 loads, the connection of a diode in parallel with
H 34 - Maximum DC1 breaking capacity
R 34 - DC coil operating range v ambient temperature
1 - Max. permitted coil voltage.
2 - Min. pick-up voltage with coil at ambient temperature.
values under the curve, an electrical life of ≥ 60·10
the load will permit a similar electrical life as for a DC1 load.
Note: the release time for the load will be increased.
34 Series - Ultra-Slim PCB relays
DC voltage (V)
400
2
level 4 (4 kV)
level 3 (2 kV)
3
can be expected.