704.702.6 EAO, 704.702.6 Datasheet - Page 80

LENS, SQUARE, BLUE

704.702.6

Manufacturer Part Number
704.702.6
Description
LENS, SQUARE, BLUE
Manufacturer
EAO
Datasheet

Specifications of 704.702.6

Lens Color
Blue
Lens Width
35mm
Lens Height
35mm
Leaded Process Compatible
Yes
Lens Shape
Square
For Use With
04 Series Pushbutton Switch
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Technical Data
>
Mechanical characteristics
0
Electrical characteristics
Electrical characteristics for AC
0
Rotary selector switch element
Terminals
Screw terminals
Terminal lead material copper wires only
max. permissible wire gage :
Single-core or stranded wire 2 x 1.5 mm² (2 x AWG 14)
flexible wire 2 x 1,5 mm² (2 x AWG 16)
Number of stages
1 to 8 positions max.
Number of contacts
1 to 16 max. normally open contacts
(contact positioning according circuit drawing)
Switching angle
Basic position of switching position "a" is 9 o'clock
Maintained action
12 max.
8 max.
6 max.
4 max.
Momentary action with release 24 °
(provide at the beginning or at the end )
Standard type of Kraus & Naimer
CG4 Hard Silver contacts with 1 μm Gold layer
CG4-1 Hard Silver contacts with 35 μm Gold layer
Minimum Voltage
20 V
Rated Impulse Withstand Voltage U
4 kV
Short Circuit Protection
Max. fuse size (gL- characteristic) 10 A
Rated short-time withstand current (1s-current) 90 A
Standards
The devices comply with : EN IEC 60947-3, VDE 0660 part 107
Rated Operational Voltage U
440 V
Rated Insulation Voltage U
440 V
Rated Thermal Current I
10 A
Rated Operational Current I
AC-15 Switching of control devices, contactors, valves etc.
110 V - 120 V
220 V - 240 V
380 V - 440 V
No load operation
10 A
78
04.2008
2.5 A
2.5 A
1.5 A
Switching angle
30 °
45 °
60 °
90 °
u
/I
th
i
e
e
imp
0
0
0
0
0
Electrical characteristics for AC (UL/Canada)
0
AC-21A Switching of resistive loads, including moderate overloads
For switchin of power >1 kW
10 A
AC-22A Switching of combined resistive or low inductive loads
including moderate overloads
220 V - 240 V
Rated Utilization Category
AC-2 Slip ring motor starting, reversing and plugging, star-delta
starting 3 phase, 3 pole
220 V - 240 V
380 V - 440 V
AC-3 Direct-on-line starting, star-delta starting
3 phase, 3 pole
1 phase, 2 pole
AC-Direct-on-line starting, reversing, plugging and inching
3 phase, 3 pole
1 phase, 2 pole
AC-23A Frequent switching of motors or other high inductive loads
3 phase, 3 pole
1 phase, 2 pole
Overvoltage category
III, valid for lines with grounded common neutral termination
Degree of pollution
3, valid for lines with grounded common neutral termination
Rated operational voltage
300 V
Rated Insulation Voltage U
300 V
Rated Thermal Current
10 A
Ampere Rating
Resisitve or low inductive loads, for switching of power >1 kW, 10 A
Ratings
Standard motor load, DOL Rating (similar AC-3)
3 phase, 3 pole
1 phase, 2 pole
Pilot Duty, Heavy
300 VAC
10 A
2.5 kW
4.5 kW
220 V - 240 V
380 V - 440 V
110 V - 120 V
220 V - 240 V
380 V - 440 V
220 V - 240 V
380 V - 440 V
110 V - 120 V
220 V - 240 V
380 V - 440 V
220 V - 240 V
380 V - 440 V
110 V - 120 V
220 V - 240 V
380 V - 440 V
110 V - 120 V
220 V - 240 V
110 V - 120 V
220 V - 240 V
277 V - 277 V
i
2.5 kW
2.2 kW
0.3 kW
0.55 kW
0.75 kW
0.37 kW
0.55 kW
0.15 kW
0.25 kW
0.5 kW
1.8 kW
3 kW
0.37 kW
0.75 kW
1.1 kW
0.75 HP
1 HP
0.33 HP
0.75 HP
0.75 HP
04