MLX90316KGO-BCG Melexis Inc, MLX90316KGO-BCG Datasheet - Page 22

no-image

MLX90316KGO-BCG

Manufacturer Part Number
MLX90316KGO-BCG
Description
IC ROTARY POS. SENSOR 16-TSSOP
Manufacturer
Melexis Inc
Series
Triaxis™r
Type
Linear - Programmabler
Datasheet

Specifications of MLX90316KGO-BCG

Sensing Range
±700mT
Voltage - Supply
4.5 V ~ 5.5 V
Current - Supply
11mA
Current - Output (max)
20mA
Output Type
Analog, PWM, SPI
Operating Temperature
-40°C ~ 125°C
Package / Case
16-TSSOP
For Use With
PTC-04-90316 - PROGRAMMER FOR HALL EFFECT 90316PTC-04-DB-90316 - BOARD DAUGHT FOR MELEXIS PTCEVB90316-GO - BOARD EVAL FOR MLX90316-GO
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Features
-
Other names
MLX90316KGO
MLX90316KGO

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
MLX90316KGO-BCG-000-RE
0
14.4.3. RGThresL, RGThresH Parameters
RGThresL & RGThresH define the boundaries within the gain setting (Rough Gain) is allowed to vary.
Outside this range, the output is set in diagnostic low.
14.5. FILTER
The MLX90316 includes 3 types of filters:
Note: if the parameter FSWAP is set to “1”, the filtering is active on the digital angle. If set to “0”, the
filtering is active on the output transfer function.
14.5.1. Hysteresis Filter
The FHYST parameter is a hysteresis filter. The output value of the IC is not updated when the digital step
is smaller than the programmed FHYST parameter value. The output value is modified when the
increment is bigger than the hysteresis. The hysteresis filter reduces therefore the resolution to a level
compatible with the internal noise of the IC. The hysteresis must be programmed to a value close to the
noise level.
Please note that for the programmable version, the FHYST parameter is set to 4 by default. If you do not
wish this feature, please set it to “0”.
14.5.2. FIR Filters
The MLX90316 features 6 FIR filter modes controlled with Filter = 0…5. The transfer function is described
below:
3901090316
Rev. 005
Hysteresis Filter: programmable by the FHYST parameter
Low Pass FIR Filters controlled with the Filter parameter
Low Pass IIR Filter controlled with the Filter parameter and the coefficients FILTER A1 and
FILTER A2
Parameter
FSWAP
FILTER
FHYST
y
n
=
i
=
Page 22 of 42
j
0
1
0 … 11 ; step 0.04
a
i
i
=
j
0
Value
0… 6
a
i
0
1
x
n
i
Rotary Position Sensor IC
Unit
deg
MLX90316
Data Sheet
May. 09

Related parts for MLX90316KGO-BCG