SS451A Honeywell Sensing and Control, SS451A Datasheet - Page 2

SENSOR OMNIPOLAR HALLEFFECT DGTL

SS451A

Manufacturer Part Number
SS451A
Description
SENSOR OMNIPOLAR HALLEFFECT DGTL
Manufacturer
Honeywell Sensing and Control
Series
SS450r
Type
Omnipolar Switchr
Datasheet

Specifications of SS451A

Sensing Range
135G Trip, -120G Release
Voltage - Supply
3 V ~ 24 V
Current - Supply
6mA
Current - Output (max)
20mA
Output Type
Digital, Open Collector
Operating Temperature
-40°C ~ 150°C
Package / Case
TO-226-3, TO-92-3 Short Body
Hall Effect Type
Omnipolar
Output Current
20mA
Sensor Case Style
TO-92
No. Of Pins
3
Supply Voltage Range
3V To 24V
Operating Temperature Range
-40°C To +150°C
Operate Point Typ
85G
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Features
-
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant
Other names
480-3587
SS451A

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
SS451A
Manufacturer:
IDT
Quantity:
1 662
Part Number:
SS451A
Manufacturer:
DHA
Quantity:
20 000
Table 1. SS351AT/SS451A Specifications (At Vs=3.0 Vdc to 24 Vdc, 20 mA load, T
Note 1: See Figure 1.
Table 2. SS351AT/SS451A Absolute Maximum Ratings
Note 1: The magnetic field strength (gauss) required to cause the switch to change state (operate and release) will be as specified
in the magnetic characteristics. To test the switch against the specified magnetic characteristics, the switch must be placed in a
uniform magnetic field.
Figure 1. SS351AT Rated Supply Voltage
2
Characteristic
Supply voltage
Supply current
Output Current
Vsat
Output leakage current
Output switching time:
Thermal resistance:
SS351AT/SS451A:
SS351AT/SS451A:
SS351AT/SS451A
Operating temperature
Storage temperature
Characteristic
Supply voltage
Applied output voltage
Output current
Magnetic flux
NOTICE
Absolute maximum ratings are the extreme limits that the device will withstand without
damage to the device. However, the electrical and mechanical characteristics are not
guaranteed as the maximum limits (above recommended operating conditions) are
approached, nor will the device necessarily operate at absolute maximum ratings.
SS451A
SS351AT
SS351AT
rise
fall
SS451A
SS351AT
Operate positive
Operate negative
Release positive
Release negative
Differential
www.honeywell.com/sensing
1
:
-40 °C to 150 °C [-40 °F to 302 °F]
-40 °C to 125 °C [-40 °F to 257 °F]
Vsupply = 12 V at 25 °C [77 °F],
at 20 mA, gauss > Bop positive
Vsupply = 5 V at 25 °C [77 °F]
Vsupply = 3 V at 25 °C [77 °F]
R
or gauss < Bop negative
gauss > Bop+ or < Bop-
L
=1.6 KOhm, C
150 °C [302 °F]
Minimum
Condition
-28.0
-0.5
L
Figure 2. Current Sinking Output Block Diagram
= 20 pF
1
Typical
Minimum
-40 [-40]
-40 [-40]
-135
-120
35
10
3
3
3
5
A
= -40 °C to 150 °C [-40 °F to 257 °F])
Typical
Maximum
233
303
4.5
3.5
-85
-50
85
50
35
no limit
28.0
28.0
20
Maximum
150 [302]
150 [302]
20.0
135
120
-35
-10
0.4
1.5
1.5
24
24
12
10
80
6
5
9
gauss
Unit
mA
V
V
°C [°F]
°C [°F]
gauss
gauss
gauss
°C/W
Unit
Vdc
mA
mA
µA
µs
V

Related parts for SS451A