SI1141-A10-GMR Silicon Laboratories Inc, SI1141-A10-GMR Datasheet - Page 33

SENS IR PROXIMITY AMB LT 8-ODFN

SI1141-A10-GMR

Manufacturer Part Number
SI1141-A10-GMR
Description
SENS IR PROXIMITY AMB LT 8-ODFN
Manufacturer
Silicon Laboratories Inc
Datasheet

Specifications of SI1141-A10-GMR

Mfg Application Notes
Si1141 Touchless Lavatory AppNote Si114x Designer's Guide AppNote Si114x Overlay Considerations AppNote Si1141 Cheek Detection in Smartphones C8051F990/Si1141 Smoke Detection AppNote Si114x irLED Guide AppNote Si114x Control Panel Guide AppNote
Output Type
Digital - I²C
Sensor Type
Proximity, Infrared and Ambient Light
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
336-1968
SI1141-A10-GM

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
SI1141-A10-GMR
Manufacturer:
SILICON LABS/芯科
Quantity:
20 000
Company:
Part Number:
SI1141-A10-GMR
Quantity:
2 500
Company:
Part Number:
SI1141-A10-GMR
Quantity:
2 500
IRQ_MODE1 @ 0x05
Reset value = 0000 0000
Note: The ALS_IM description apples only to sequencer revisions A03 or later.
7:6
5:4
2:0
Bit
Name
3
Type
Bit
Reserved Reserved.
PS2_IM
PS1_IM
ALS_IM
Name
7
PS2_IM
PS2 Interrupt Mode applies only when PS2_IE is also set.
00: PS2_INT is set whenever a PS2 measurement has completed.
01: PS2_INT is set whenever the current PS2 measurement crosses the PS2_TH
threshold.
11: PS2_INT is set whenever the current PS2 measurement is greater than the
PS2_TH threshold.
PS1 Interrupt Mode applies only when PS1_IE is also set.
00: PS1_INT is set whenever a PS1 measurement has completed.
01: PS1_INT is set whenever the current PS1 measurement crosses the PS1_TH
threshold.
11: PS1_INT is set whenever the current PS1 measurement is greater than the
PS1_TH threshold.
ALS Interrupt Mode function is defined in conjunction with ALS_IE[1:0].
ALS_IE[1:0] / ALS_IM[2:0]:
00 / 000: Neither ALS_INT[1] nor ALS_INT[0] is ever set.
01 / 000: ALS_INT[0] sets after every ALS_VIS sample.
x1 / x01: Monitors ALS_VIS channel, ALS_INT[0] asserts if measurement exits window
between ALS_LOW_TH and ALS_HIGH_TH.
x1 / x11: Monitors ALS_IR channel, ALS_INT[0] asserts if measurement exits window
between ALS_LOW_TH and ALS_HIGH_TH.
1x /10x: Monitors ALS_VIS channel, ALS_INT[1] asserts if measurement enters win-
dow between ALS_LOW_TH and ALS_HIGH_TH.
1x /11x: Monitors ALS_IR channel, ALS_INT[1] asserts if measurement enters window
between ALS_LOW_TH and ALS_HIGH_TH.
RW
6
5
PS1_IM
RW
Rev. 1.1
4
Function
3
2
Si1141/42/43
ALS_IM
RW
1
0
33