HW4B-X4F01-R IDEC, HW4B-X4F01-R Datasheet - Page 4

EMERGENCY STOP SWITCH, 10A, 220V

HW4B-X4F01-R

Manufacturer Part Number
HW4B-X4F01-R
Description
EMERGENCY STOP SWITCH, 10A, 220V
Manufacturer
IDEC
Datasheet

Specifications of HW4B-X4F01-R

Contact Configuration
SPST
Contact Voltage Ac Nom
600V
Contact Voltage Dc Nom
220V
Contact Current Max
10A
Actuator Style
Mushroom
Switch Terminals
Screw
Actuator Diameter
40mm
Ip Rating
65
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
6
6
Revolutionary “Safe Break Action” Design
“Through IDEC’s innovative design, their E-Stops
Contact Block
have increased the safety of our personnel”
Operator
NC Contact
Closed (On)
X Series, The Safe Break Action E-Stops!
Internal view while removing the contact block
Reach for the “Safe Break Action”
When the contact block is removed from the operator the main contact
(NC) is forced to open (OFF). When removing the contact block, the cam
provides a direct opening action to open the contact.
1
Unrivalled safety:
IDEC Emergency Stop Switches include exclusive technology that has
changed the way E-Stop switches are designed. This “safe break action”
concept provides greater levels of human safety.
Conventional E-Stop switches are designed with spring pressure on the
Normally Closed (NC) contacts, keeping them in the closed position and
allowing a machine to operate. But improper installation or excessive force
to the button in an emergency may break or dislodge a vital part, causing
the spring loaded contact to stay closed. This situation renders the E-Stop
incapable of stopping the machine, and can lead to catastrophic events,
personal injury and possible loss of life.
However, IDEC X-Series E-Stops use a “safe break action,” which reverses
the energy direction and uses the spring-pressure to guarantee that the NC
contacts will open if the emergency switch is damaged or the contact blocks
separate due to excessive force. This is the E-Stop switch you can rely on in
a life threatening situation.
2
Mechanical Engineer
NC Contact
Open (Off)
3
Safe Break Action Technology
4
X-Series E-Stops have lower potential energy in the
“Locked” (Latching) position than in the “Normal”
(Reset) position. When the switch is damaged from an
excessive shock, the main contact (NC) moves toward
the OFF (Safe) position.
Direct Opening Action
Even if the contacts are welded, the force applied
on the button directly opens the contact.
Rated Insulation Voltage: 250V minimum
Rated Thermal Current: 5A minimum
Safety Interlock Mechanism
Contacts are opened when the operator is locked, and
remain opened until the operator is unlocked
intentionally. (IEC60947-5; 6:2)
Two E-Stops in One
Push to lock, Pull/Turn to Reset
The X-Series E-Stops can be reset either by pulling or
turning the button. With traditional E-Stops, you need to
choose between Push-Pull or Pushlock Turn Reset. With
the IDEC X Series E-Stops you get both in one switch.
(Except XN4E which is only Pushlock Turn Reset).
Safety You Should Know About
XA (16mm)
XW (22mm)
XN (30mm)
Depth Behind the Panel
Model
XN (30mm)
Depth (mm)
27.9
48.7
47.7
60.4
61.4
1 - 4 contacts, both illuminated & non-illuminated
1 - 4 contacts, both illuminated & non-illuminated
1 - 4 contacts, plastic bezel (XN1E)
1 - 4 contacts, flush bezel (XN5E)
1 - 4 contacts, padlock (XN4E)
Description
Normal Status
Normal Status
XW (22mm)
NC contacts are always
on standby to turn on
(hazardous)
NC
contacts:
ON
(machine
can
operate)
NC contacts:
ON (machine
can operate)
Pull Reset
Latched
Latched
NC contacts:
OFF
(machine
cannot
operate)
Traditional
E-Stop
Depth with 4 Contacts
Normal Status
XA (16mm)
Normal Status
NC contacts: OFF
(machine cannot
operate)
NC contacts are always on
standby to turn off (safe)
www.idec.com/usa/estop
NC
contacts:
ON
(machine
can operate)
Turn Reset
Series
XW
Latched
Latched
~20mm
NC
contacts:
OFF
(machine
cannot
operate)
7