G6D-4B 24DC Omron, G6D-4B 24DC Datasheet - Page 3

RELAY MODULE, 4SPNO, 24VDC

G6D-4B 24DC

Manufacturer Part Number
G6D-4B 24DC
Description
RELAY MODULE, 4SPNO, 24VDC
Manufacturer
Omron
Datasheet

Specifications of G6D-4B 24DC

Relay Type
Power
Coil Voltage Vdc Nom
24V
Contact Current Max
5A
Contact Voltage Ac Nom
250V
Contact Voltage Dc Nom
30V
Coil Resistance
2.88kohm
Coil Type
DC
Coil Current
8.3mA
Nom Operating
RoHS Compliant
Contact Configuration
SPNO
Rohs Compliant
Yes
Engineering Data
The rated values approved by each of the safety standards may be different from the performance characteristics individually defined
in this catalogue.
UL Approval
CSA Approval
EN/TÜV Approval
Maximum Switching Power
Ambient Temperature vs.
Operating/Recovery Voltage
G6D-1A-ASI
G6D-1A-ASI
G6D-1A-ASI
G6D-1A-ASI
100
0.5
0.3
0.1
PCB Power Relay – G6D
50
30
10
80
60
40
20
−40
Approved Standards
5
3
1
0
0
Sample: G6D1A
Quantity: 5
−20
3
DC resistive
load
Model
Model
Model
DC inductive
load
5
10
0
Ambient temperature (°C)
30
20
Switching voltage (V)
AC inductive
load
cosφ=0.4
100
AC resistive load
Operating voltage
Recovery voltage
40
1
1
1
250 500 1,000
Number of poles
Number of poles
Number of poles
60
(File No. E41515) UL508
max.
min.
max.
min.
(File No. LR31928) C22.2 No. 14
X
X
80
(Registration No. R50029064/EN61810-1)
Not energized
Measurement conditions: Impose a shock in the
±X, ±Y, and ±Z directions three times each with
the Relay energized to check the shock values
that cause the Relay to malfunction.
X
Z'
Endurance
Malfunctioning Shock
G6D-1A-ASI
300
500
100
30
50
10
3
5
0
Energized
5 to 24 VDC
5 to 24 VDC
5, 12, 24 VDC
250-VAC/30 VDC inductive load
(cosφ=0.4/ L/R=7 ms)
1
Coil ratings
Coil ratings
Coil ratings
2
250-VAC/30-VDC resistive load
Y
Y'
1,000
800
600
400
200
206
3
4
Unit: m/s
Switching current (A)
5
6
2
Z
X'
7
Y
Y'
Shock direction
8
X
5 A, 250 VAC (General Use)
5 A, 30 VDC
5 A, 250 VAC (General Use)
5 A, 30 VDC (Resistive)
5 A, 250 VAC (cosø=1.0)
5 A, 30 VDC (0 ms)
Coil terminals
9
10
X'
Contact Ratings
Contact Ratings
Contact Ratings
Z
Z'
Ambient Temperature vs.
Maximum Coil Voltage
Note: The maximum coil voltage is the
200
180
160
140
120
100
80
60
0
maximum voltage that can be
applied to the relay coil
23 30
40
Ambient temperature (°C)
6,000
6,000
70,000
Number of test operations
Number of test operations
Number of test operations
50
60
70
80
90
61

Related parts for G6D-4B 24DC