Specifications of PBA-1

Supply Voltage Max
130VAC
Switch Terminals
Screw
Supply Voltage Min
105VAC
Frequency, Operating
50⁄60 Hz
Function
Module, Power Block
Technology
Photoelectric
Lead Free Status / Rohs Status
RoHS Exempt Product
4
Selection of MULTI-BEAM Components
MULTI-BEAM sensors are made up of three components: scanner
block, power block, and logic module. This is true for all MULTI-
BEAMs with the exception of opposed mode emitter units which
require only a power block (no logic module).
The first decision in the component selection process is to determine
which family of MULTI-BEAM sensors is appropriate for the applica-
tion: 3- and 4-wire, or 2-wire.
Next, decide which scanner block (within the selected family) is best for
the application. The guidelines in the catalog introduction will help you
to determine the best sensing mode. Then narrow the choice by
comparing the specifications listed in the following charts and on the
pages referenced in the charts.
Finally, choose a power block and logic module to complete the
MULTI-BEAM assembly. Components snap together without inter-
wiring to form a complete photoelectric sensing system that meets your
exact requirements while maintaining the simplicity of a self-contained
sensor.
If you have any questions about selecting MULTI-BEAM components,
please contact your Banner sales engineer or call Banner's Applications
Department at (612) 544-3164 during normal business hours.
3- and 4-wire Systems
Scanner Blocks
Model
SBE & SBR1
SBED & SBRD1
SBEX & SBRX1
SBEV & SBRX1
SBEXD & SBRXD1
SBLV1
SBLVAG1
SBL1
SBLX1
SBD1
SBDL1
SBDX1
SBDX1MD
SBCV1
SBCVG1
SBC1
SBC1-4
SBC1-6
SBCX1
SBCX1-4
SBCX1-6
SBEF & SBRF1
SBEXF & SBRXF1
SBFX1
SBF1
SBF1MHS
SBFV1
SBFVG1
SBAR1
SBAR1GH
SBAR1GHF
(pages 6 through 23)
Sensing Mode
Opposed: high speed
Opposed: high speed, narrow beam
Opposed: high power, long range
Opposed: visible beam
Opposed: high power, wide beam angle
Retroreflective: high speed, visible beam
Retroreflective: polarized beam (anti-glare)
Retroreflective: high speed, infrared beam
Retroreflective: high power, long range
Diffuse (proximity): high speed
Diffuse (proximity): medium range
Diffuse (proximity): high power, long range
Diffuse (proximity): wide beam angle
Convergent beam: high speed, visible red
Convergent beam: high speed, visible green
Convergent beam: high speed, infrared
Convergent beam: high speed, infrared
Convergent beam: high speed, infrared
Convergent beam: high power, infrared
Convergent beam: high power, infrared
Convergent beam: high power, infrared
Opposed fiber optic (glass fibers): high speed see specs
Opposed fiber optic (glass fibers): high power see specs
Fiber optic (glass fibers): high power, infrared see specs
Fiber optic (glass fibers): high speed, infrared
Fiber optic (glass fibers): very high speed
Fiber optic (glass fibers): visible red
Fiber optic (glass fibers): visible green
Ambient light receiver
Ambient light receiver: high gain
Ambient light receiver: for glass fiber optics
Lower Cover
(supplied with
Scanner Block)
Upper Cover (lens)
(supplied with
Scanner Block)
Range
150 feet
700 feet
100 feet
100 feet
12 inches
24 inches
24 inches
1.5-inch focus
1.5-inch focus
1.5-inch focus
1.5-inch focus
see specs
see specs
see specs
see specs
see specs
see specs
see specs
10 feet
30 feet
30 feet
15 feet
30 feet
6 feet
4-inch focus
6-inch focus
4-inch focus
6-inch focus
Logic
Timing
Adjustment
Logic Module
LIGHT/DARK
Operate Select
Response
1 millisecond
1 millisecond
10 milliseconds
10 milliseconds
10 milliseconds
1 millisecond
1 millisecond
1 millisecond
10 milliseconds
1 millisecond
1 millisecond
10 milliseconds
10 milliseconds
1 millisecond
1 millisecond
1 millisecond
1 millisecond
1 millisecond
10 milliseconds
10 milliseconds
10 milliseconds
1 millisecond
10 milliseconds
10 milliseconds
1 millisecond
0.3 millisecond
1 millisecond
1 millisecond
10 milliseconds
10 milliseconds
10 milliseconds
Scanner Block
Housing
Wiring
Terminals
Power
Block
Page
p. 7
p. 7
p. 7
p. 7
p. 7
p. 8
p. 8
p. 8
p. 8
p. 9
p. 9
p. 9
p. 9
p. 10
p. 10
p. 10
p. 10
p. 10
p. 10
p. 10
p. 10
p. 11
p. 11
p. 11
p. 12
p. 12
p. 13
p. 13
p. 14
p. 14
p. 14

Related parts for PBA-1

PBA-1 Summary of contents

Page 1

Selection of MULTI-BEAM Components MULTI-BEAM sensors are made up of three components: scanner block, power block, and logic module. This is true for all MULTI- BEAMs with the exception of opposed mode emitter units which require only a power block ...

Page 2

... Systems Power Blocks Model PBT PBT2 PBP PBT-1 PBT48 PBP48 PBT48-1 PBD-2 PBD PBD-1 PBA PBAQ PBAT PBO PBAM PBA-1 PBB PBBT PBOB PBB-1 Logic Modules Model LM1 LM3 LM5 LM5R LM5-14 LM5T LM4-2 LM4-2NR LM8-1 LM8A LM6-1 LM8 ...

Page 3

... Systems (pages 24 through 29) Power Blocks Model 2PBD 2PBA 2PBB 2PBR 2PBR2 Logic Modules Model 2LM3 2LM5 2LM5R 2LM5-14 2LM5T 2LM4-2 LMT MULTI-BEAM Other Systems Edgeguide Systems (data sheet 03506) MULTI-BEAM 3- & 4-WIRE SCANNER BLOCKS DESCRIPTION MULTI-BEAM 3- & 4-wire scanner blocks offer a complete comple- ment of sensing modes ...

Page 4

... HIGH-POWER SCANNER BLOCK OPPOSED MODE OBJECT DIFFUSE MODE OBJECT For complete information on glass fiber optic assemblies and accessories, see product catalog. 3- & 4-wire Scanner Blocks Models Excess Gain SBEF & SBRF1 1000 Range: see excess gain curve Response: 1ms on/off E Repeatability: 0 ...

Page 5

... Response time of a MULTI-BEAM sensor is also a function of the power block. For this reason, only power blocks which switch dc (e.g. PBT, PBP, PBO, PBAT, etc) should be used if the fast response time of the scanner block utilized ...

Page 6

... Fibers allow a match of the light image to the geometry of the registration mark. Scanner block model SBFVG1 will sense most bold color differences, including red-on-white. Use only power blocks which switch dc (e.g. PBT, PBP, PBO, PBAT, etc.) for fast response. Beam Pattern SBFV1 1 ...

Related keywords