OS-SS3 PANASONIC EW, OS-SS3 Datasheet - Page 17

no-image

OS-SS3

Manufacturer Part Number
OS-SS3
Description
SLIT MASK 0.5X3MM FOR SH-31R/31G/33R
Manufacturer
PANASONIC EW
Datasheet

Specifications of OS-SS3

Rohs Compliant
YES
Mounting
Wiring
Notes: 1) Not incorporated on the emitter and the basic type sensor.
CX-41□
Operation indicator (Orange)(Note 2)
The tightening torque should be 0.5 N·m or less.
Make sure that the power supply is off while wiring.
Take care that wrong wiring will damage the sensor.
Verify that the supply voltage variation is within the rating.
If power is supplied from a commercial switching regulator,
ensure that the frame ground (F.G.) terminal of the power
supply is connected to an actual ground.
In case noise generating equipment (switching regulator,
inverter motor, etc.) is used in the vicinity of this product,
connect the frame ground (F.G.) terminal of the equipment
to an actual ground.
PRECAUTIONS FOR PROPER USE
DIMENSIONS (Unit: mm in)
Stability indicator (Green)(Note 3)
2) It is the power indicator (green) on the emitter.
3) Not incorporated on the emitter.
4) Basic type: 0.5 m
Sensitivity adjuster (Note 1)
0.441
11.2
Beam
axis
2-M3×0.5
thru-hole threads
Never use this product as a sensing device
for personnel protection.
In case of using sensing devices for
personnel protection, use products which
meet laws and standards, such as OSHA,
ANSI or IEC etc., for personnel protection
applicable in each region or country.
1.220
31
15.5
0.020
0.610
1.000
25.4
1.640 ft
M3 (length 12 mm
screw with washers
0.787
20
0.465
11.8
3
0.118
long.
(
0.091
2.3
ø3.7
3-core (emitter: 2-core)×0.2 mm
insulator diameter: ø1.2
7.85
3.95
2 m
Operation mode switch (Note 1)
)
0.472
6.562 ft
0.309
0.156
ø0.146
in)
cable,
long (Note 4)
Sensor
mounting
bracket
(Optional)
Sensor
ø0.047
2
Others
Notes: 1) Not incorporated on the emitter.
CX-41□-Z
The CAD data in the dimensions can be downloaded from the website:
Do not run the wires together with high-voltage lines or
power lines or put them in the same raceway.
This can cause malfunction due to induction.
Extension up to total 100 m
both emitter and receiver) is possible with 0.3 mm
more, cable. However, in order to reduce noise, make the
wiring as short as possible.
Make sure that stress by forcible bend or pulling is not
applied directly to the sensor cable joint.
This product has been developed / produced for industrial
use only.
Do not use during the initial transient time (50 ms) after
the power supply is switched on.
Take care that the sensor is not directly exposed to
fl uorescent light from a rapid-starter lamp or a high
frequency lighting device, as it may affect the sensing
performance.
This sensor is suitable for indoor use only.
Do not use this sensor in places having excessive vapor,
dust, etc., or where it may come in direct contact with
water or corrosive gas.
Take care that the sensor does not come in direct contact
with water, oil, grease or organic solvents, such as,
thinner, etc.
This sensor cannot be used in an environment containing
infl ammable or explosive gases.
Never disassemble or modify the sensor.
Operation indicator (Orange)(Note 2)
ø0.370
2) It is the power indicator (green) on the emitter.
0.441
11.2
ø9.4
Stability indicator (Green)(Note 1)
Sensitivity adjuster (Note 1)
Beam
axis
1.673
Operation mode switch (Note 1)
42.5
2-M3×0.5
thru-hole threads
1.398
35.5
1.220
31
15.5
0.610
0.020
1.000
25.4
328.084 ft
panasonic-electric-works.net/sunx
0.787
20
0.465
3
0.118
11.8
(
0.091
7.85
2.3
3.95
M8 connector
(thru-beam type:
)
0.309
0.156
2
, or
Sensor
16

Related parts for OS-SS3