FD-B8 PANASONIC EW, FD-B8 Datasheet - Page 9

PHOLOELECTRIC SENSOR

FD-B8

Manufacturer Part Number
FD-B8
Description
PHOLOELECTRIC SENSOR
Manufacturer
PANASONIC EW
Type
Reflectiver
Datasheet

Specifications of FD-B8

Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Wiring- and labor-saving design allows side-
by-side configuration for up to sixteen units
One unit can be used as either a main unit or sub unit
FX-305
Eco-friendly
Lead-free solder used is gentle on the environment
Selectable cable length
The amplifier unit can be used as either a main unit or a sub unit.
This feature allows for easy mounting in the side-by-side
configuration. The main and sub unit functions are distinguished
only by the proper use of the main cable and the sub cable.
Moreover, inventory management and maintenance is simplified.
FX-301(-HS)
SUNX promotes the use of lead-free materials in all of its sensor
manufacturing processes including those used for the FX-300
series of digital fiber sensors.
Made available are 3 lengths,
1 m
and 5 m
your application require-
ments. This helps reduce
the waste caused by cutting
cables and lightens the
installation workload.
3.281
16.404
ft, 2 m
Main cable (4-core)
CN-74-C
Sub cable (2-core)
CH-72-C
Main cable (3-core)
CN-73-C
Sub cable (1-core)
CH-71-C
ft, to suit
6.562
ft,
Used for intermediate terminal block
Directly connected to the PLC
1 m
Main cable
Identical part numbers eliminate the need for
costly inventory management labor
3.281 ft
2 m
6.562 ft
FX-301/B/G/H
5 m
5 m
16.404 ft
16.404 ft
FX-301-HS
Sub cable
cable length type
FX-305
To PLC
To PLC
An optical communication function allows up
to 16 sensors to be adjusted simultaneously
Settings can be entered directly using numerical input
The optical communication function allows the data that is currently
set to be copied and saved all at once for all amplifiers connected
together from the right side. This greatly reduces troublesome setup
tasks and makes setup much smoother. In addition, troublesome
adjustment operations at
times such as when
replacing sensors can
also
easily and data can also
be copied and stored
using
communication function.
Every function can be directly set merely by the input of a four digit code
(numbers) from the code table. This convenient feature is easy to set up.
In the event that settings are accidentally changed at the operating
site, merely entering the correct code can restore the original
settings. This results in easy and quick maintenance.
Reduced power consumption possible (ECO mode)
Environmentally friendly packaging
m Use the optical communication function for only the same types of sensors. Furthermore, the FX-301-HS
This turns off the digital display to reduce power consumption to
approximately 600 W or less. (960 W is consumed when the display
is on.)
With regard to effects on the
environment, we only utilize
the simplest of packaging
methods greatly contributing
to the reduction in wastes
generated by your worksite.
Also, the bags are made of
polyethylene,
that doesn’t give off polluting
gases when burned.
m
is not equipped with optical communication function capability. Refer to p. 30 for details.
be
the
carried
a
optical
substance
out
First digit: Settings for response time and hysteresis
Second digit: Settings for L/D ON and display mode
Fourth digit: Timer period settings
Third digit: Settings for Adjust lock and timer
Single copy & save operation for all amplifiers
Polyethylene packaging
Eco-friendly
Concept 5
FX-301/B/G/H
FX-305
8