D10DPFP BANNER ENGINEERING, D10DPFP Datasheet - Page 6

Photoelectric Sensor

D10DPFP

Manufacturer Part Number
D10DPFP
Description
Photoelectric Sensor
Manufacturer
BANNER ENGINEERING
Type
Dual Discrete Outputr
Datasheets

Specifications of D10DPFP

Sensor Output
PNP
Sensor Input
Fiber Optic
Output Type
Transistor
Contact Current Max
150mA
Switch Terminals
Connector
Body Style
Rectangular
Brand/series
Expert™
Current, Switching
150 mA
Function
Fiber Optic
Indicator
LCD
Ip Rating
IP50
Material, Casing
Black ABS⁄Polycabonate Alloy (Housing)
Material, Cover
Polycarbonate
Mounting Type
DIN Rail
Output
PNP
Primary Type
Photoelectric
Sensing Mode
Selectable
Technology
Photoelectric
Temperature, Operating
-20 to +55 °C
Termination
Cable
Time, Response
50 μs, 200 μs, 1 ms, 2.5 ms
Voltage, Supply
24 VDC
Accessories Available
Cordsets and Plastic Fiber Optic Cable
Fiber Optic Sensor Type
Dual Discrete Output
Lead Free Status / Rohs Status
RoHS Exempt Product
D10 Expert
• S ets a single ON condition that extends 200 counts above and below the taught condition
• All other conditions (lighter or darker) result in OFF output
Window SET is most useful when a product may not always appear in the same place, or
when other signals may appear. Window SET designates a sensing window, with the Output
ON condition inside the window, and the Output OFF conditions outside the window (see
Figure 6). The sensor accepts a single sensing condition, and adds switching thresholds and
hysteresis above and below that condition to create a sensing window. Output ON and OFF
conditions can be reversed by changing Light/Dark Operate status in SETUP mode.
Window SET and Manual Adjust
Using Manual Adjust with Window SET expands or contracts the size of the window.
6
• S ensing window (sensitivity) is adjustable using “+” and “-” buttons (see Manual Adjust,
(including ±100 counts hysteresis)
page 9)
P/N 64154 rev. F
• P ress and hold
• P resent sensing
• D ouble-click the
Static (-) button
> 2 seconds.
condition.
Static button.
Push Button
Dual Discrete Outputs
Single-Point Window SET
T
T
• Present sensing condition.
• Single-pulse
• Double-pulse
T
the remote line.
the remote line.
T
T
0.04 sec. ≤ T ≤ 0.8 sec.
T
Remote
T
T
T
T
T
T
T
T
T
T
• Display flashes “1st”
• Arrow icon turns red
• Display flashes “2nd”
• Arrow icon turns red
TEACH conditions acceptable:
• Display flashes “sngl,”
then “pt” twice
• Sensor returns to RUN
• Arrow icon turns green
TEACH conditions unacceptable:
• Display flashes “fail” and
returns to “1st”
• Arrow icon remains red
• After 60 seconds, sensor
mode with new settings.
returns to RUN mode
(Arrow icon turns green)
without changing settings.
Banner Engineering Corp.
www.bannerengineering.com • Tel: 763.544.3164
Figure 6. Single-Point Window SET and
(no signal)
Darkest
Output OFF
T
T
T
Hysteresis (Light Operate shown)
100 counts
Hysteresis
T
Result
Sensing window size adjusted by
± 100 counts from the
presented condition
window thresholds
Sensor positions
Manual Adjust
200 counts
Output ON
Condition
Taught
Minneapolis, MN U.S.A.
100 counts
Hysteresis
Output OFF
Most Light
(saturated
signal)