2489-32-36-2-AFA-1 YOKOGAWA, 2489-32-36-2-AFA-1 Datasheet

TRANSDUCER, TRUE RMS VOLTAGE, 1mA

2489-32-36-2-AFA-1

Manufacturer Part Number
2489-32-36-2-AFA-1
Description
TRANSDUCER, TRUE RMS VOLTAGE, 1mA
Manufacturer
YOKOGAWA
Datasheet

Specifications of 2489-32-36-2-AFA-1

Transducer Function
True RMS Voltage
Accuracy %
0.2%
Output Current Max
1mA
Operating Temperature Range
-20°C To +60°C
External Depth
95.72mm
Frequency Max
60Hz
Frequency Min
50Hz
Rohs Compliant
NA
Lead Free Status / RoHS Status
na
YOKOGAWA
POWER
TRANSDUCER
CATALOG

Related parts for 2489-32-36-2-AFA-1

2489-32-36-2-AFA-1 Summary of contents

Page 1

... YOKOGAWA POWER TRANSDUCER CATALOG ...

Page 2

... COMBINATION WATT / VAR TRANSDUCERS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .PAGE 12 POWER FACTOR TRANSDUCERS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .PAGE 14 PHASE ANGLE TRANSDUCERS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .PAGE 16 FREQUENCY TRANSDUCERS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .PAGE 18 JUXTA 2489 SERIES ACCURACY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .PAGE 20 SELECTING A WATT OR VAR TRANSDUCER . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .PAGE 21 TRANSDUCER TERMINOLOGY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .PAGE 22 PLASTIC CASE MINIATURE TRANSDUCERS - 0.5% ACCURACY 2371-2378 FOOT MOUNT / 2461-2468 DIN RAIL MOUNT . . . . . . . . . . . . . . . . . . .PAGE 24 ...

Page 3

... GENERAL The 2469 and 2489 AC Average Current transducers produce an analog DC signal output corresponding to the average value of the AC input. The true RMS versions always require external power and produce an analog DC output corresponding to the true RMS value of the input signal. 2) SPECIFICATIONS Model # Input Current ...

Page 4

... AUXILIARY POWERED 246931 248931 3 (4) Output (5) Aux. power AFA 0-1 mADC 0 (21 & 23 only) AFA 0-1 mADC (TRMS only) 1 AHD 4-20 mADC 2 (21 & 31 only) LINE ...

Page 5

... GENERAL The 2469 and 2489 AC Average Voltage transducers produce an analog DC signal output corresponding to the average value of the AC input. The true RMS versions always require external power and produce an analog DC output corresponding to the true RMS value of the input signal. 2) SPECIFICATIONS Model # Input Voltage ...

Page 6

... GENERAL The 2469 series isolator provides an isolated analog output proportional to the DC voltage or current input. Standard inputs are 50mVDC and 1 mADC. Auxiliary power is required to power the isolator. Other DC inputs and power options are available on special order from Yokogawa. 2) SPECIFICATIONS Model # Input signal ranges ...

Page 7

... GENERAL The 2469 and 2489 AC Watt transducers produce an analog output equal to the Watts measured by the input. The typical calibration is 500 Watts / element for 120V and 5A AC transformer secondary inputs. 2) SPECIFICATIONS Model # Current input / range Current input over range capability Current input burden ...

Page 8

... GENERAL The 2469 and 2489 AC VAR transducers produce an analog output equal to the VARS measured by the input. The typical calibration is 500 VARS / element for 120V and 5A AC transformer secondary inputs. 2) SPECIFICATIONS Model # Current input / range Current input over range capability Current input burden ...

Page 9

... GENERAL The 2469 and 2489 combined WATT/VAR transducers produce an analog output equal to the WATTS and VARS measured by the input. 2) SPECIFICATIONS Model # Current input / range Current input over range capability Current input burden Voltage inputs and range: Input powered range Auxiliary powered range ...

Page 10

... GENERAL The 2469 and 2489 Power Factor transducers have an analog output corresponding to 1- Cosine of the phase angle of the input current relative to the input voltage signal. The analog output will indicate lead- ing or lagging Power Factor by its direction from center which would be either 12mA based on output selection ...

Page 11

... GENERAL The 2469 and 2489 Phase Angle transducers have an analog output corresponding to the phase angle of the input current relative to the input voltage signal. The analog output will indicate leading or lagging Phase Angle by its direction from center which would be either 12mA based on output selection. ...

Page 12

... GENERAL The 2469 and 2489 Frequency transducers have an analog output corresponding to the frequency of the AC input voltage. These transducers are capable of high accuracy measurement over various frequency ranges. 2) SPECIFICATIONS Model # Voltage inputs and range: Input powered range Auxiliary powered range Voltage input burden Rated outputs Accuracy: ± ...

Page 13

... ORDER FORMAT 2469 / 89 Model# (1) Transducer function 2469 81 ± 0.5 Hz deviation 2489 82 ± deviation 83 ± deviation 84 ± deviation 84 ± deviation 85 ± deviation 86 ± deviation 5) CONNECTION DIAGRAMS OUTPUT 6) MOUNTING AND OUTLINE DIMENSIONS: (111.6) ➤ 4.394 (120.65) ➤ 4.750 ➤ 5.236 (1) (2) (3) (4) ( (2) Input ...

Page 14

GENERAL The 2371-2378 and 2461-2468 series of power transducers combine high performance with compact size. Most of these transducers are self powered except isolators and True RMS Amps and Volts which require auxiliary power. Accuracy of ...

Page 15

GENERAL SPECIFICATIONS Overrange capability Dielectric strength between: Current input: 1) Input terminals & case - 2600VAC for 1 minute 1000% of rated input for 5 sec. 2) Input & output terminals - ...