2489-64-54-0-AHF-1-P YOKOGAWA, 2489-64-54-0-AHF-1-P Datasheet - Page 16

TRANSDUCER, VAR, 60HZ, 120V, 12 ± 8mA DC

2489-64-54-0-AHF-1-P

Manufacturer Part Number
2489-64-54-0-AHF-1-P
Description
TRANSDUCER, VAR, 60HZ, 120V, 12 ± 8mA DC
Manufacturer
YOKOGAWA
Datasheet

Specifications of 2489-64-54-0-AHF-1-P

Transducer Function
VAR 3P4W (2.5 Element)
Transducer Output Type
12 ± 8mADC
Supply Voltage Min
85VAC
Supply Voltage Max
135VAC
Transducer Input Current Ac
5A
Frequency
60Hz
Supply Voltage
120VAC
Rohs Compliant
NA
Lead Free Status / RoHS Status
na
1) GENERAL
2) SPECIFICATIONS
3) STANDARD MODELS (0-1-0 PF)
NOTE: See order format on next page for additional ratings, frequency calibrations, power-up and output options.
Model #
Current input / range
Current input over range capability
Current input burden
Voltage inputs and range:
Voltage input burden per element
Sustained Voltage input overange
Rated outputs
Accuracy
Output calibration
External calibration adjustment
Response time
Output ripple
Isolation
Surge Withstand Capability
Insulation resistance
Operating temperature
Operating humidity
Temperature effect
External magnetic field
Influence of input Voltage
Influence of input Current
Low current detection
Weight
Shock
Vibration
UL Recognition
120 VAC, 5AAC, 60 Hz, input powered
PF- Single phase / ±1mA output
PF- Single phase / 12±8mA output
PF- 3P3W balanced / ±1mA output
PF- 3P3W balanced / 12±8mA output
PF- 3P4W balanced / ±1mA output
PF- 3P4W balanced / 12±8mA output
The 2469 and 2489 Power Factor transducers have an analog output corresponding to 1- Cosine of the
phase angle of the input current relative to the input voltage signal. The analog output will indicate lead-
ing or lagging Power Factor by its direction from center which would be either 0 mA or 12mA based on
output selection.
Auxiliary power supply options <5.0 VA burden.
Input powered range
Auxiliary powered range
J U X T A
P O W E R
4-12-20 mADC into a 750Ω max. load; 15VDC output compliance
150% of rated input without damage (Auxiliary powered only)
0.3% of FS peak-to-peak max.
100-135VAC
IEEE472/ANSI C37.90.1 - 1989, JIS C1111 (5KV 1.2 x 50 microseconds)
±1mADC into a 10kΩ max. load; 10VDC output compliance
< 0.5VA
F A C T O R
120V
±500 PPM / °C of span
Span: ± 2% minimum
Zero: ± 1% minimum
<4% of rated current
0-120% rated input
246971-540-AFB-0-P
246971-540-AHF-0-P
246973-540-AFB-0-P
246973-540-AHF-0-P
246974-540-AFB-0-P
246974-540-AHF-0-P
> 10 megohm / 500VDC input/output/power/case
14
<1% of span
0-1-0 Power Factor or 0.5-1-0.5 Power Factor
<0.2% after 16.7 Hz, 4 mmp-p 1 hour, 3 Axis
0 - 90% relative humidity (non-condensing)
2500 VAC input to output, power and case
<2% of span
2000 VAC aux. power to output and case
<0.2% after 50G, 3 Axis and 6 repetitions
2469
2469
< 400 milliseconds (0-99% of output)
1000% of rated input for 5 seconds
200% of rated input continuous
T R A N S D U C E R S
200-264VAC
0-1 Amp AC or 0-5 Amp AC
10 to 200% of rated input
< 1.0VA
500 VAC output to case
< 0.2VA per element
240V
< 0.2% at 400 AT/m
±0.01 Power Factor
1000g (2.2 lbs.)
-20°C to +60°C
File # E60579
<0.02 PF for 20-200% rated input current
Self pwr.±0.01 max. in range of Aux. Pwr
0.5% of FS peak-to-peak max.
85-135VAC
Aux. Pwr.±0.01 max.±20% rated V.
< 0.5VA
Span: ± 10% minimum
0-120% of rated input
120V
±150 PPM / °C of span
Zero: ± 5% minimum
248971-540-AFB-0-P
248971-540-AHF-0-P
248973-540-AFB-0-P
248973-540-AHF-0-P
248974-540-AFB-0-P
248974-540-AHF-0-P
4% of rated input
2489
2489
170-264VAC
< 1.0VA
240V