TA25DU1.0 ABB, TA25DU1.0 Datasheet - Page 12

RELAY, OVERLOAD, A9-A30, 0.63-1

TA25DU1.0

Manufacturer Part Number
TA25DU1.0
Description
RELAY, OVERLOAD, A9-A30, 0.63-1
Manufacturer
ABB
Datasheet

Specifications of TA25DU1.0

Overload Adjustment Current Min
0.63A
Overload Adjustment Current Max
1A
Svhc
No SVHC (18-Jun-2010)
Approval Bodies
CSA, UL
Contact Rating
0.63 - 1.0 A
External Depth
94mm
External Length / Height
94mm
For Use With
A
Ordering details
Rated
operat.
current
AC-3
400 V
A
15.5
22
30
44
50
72
85
105
119
* For other short-circuit protection devices, please consult our co-ordination tables
Control circuit
Designed for "separate control supply":
The star-delta starters are delivered with their control
circuit not connected to the power circuit.
The control circuit supply is to be connected according
to the wiring diagram when putting the starter into service.
Please consult us for "direct control supply".
ABB Control
>>
Starters in kit form ....................................... page 2/16
Power AC-3
4-pole motor - 50/60 Hz
380 V
400 V
kW
7.5
11
15
22
25
37
45
55
63
415 V
kW
7.5
11
15
22
25
37
45
55
70
-
(Order the thermal O/L relay separately, see page 2/12)
690 V
kW
5.5
7.5
11
15
18.5
37
45
59
63
YKA ..-30E Star-Delta Starters
Open Type Version, with Interlock
Protection by Thermal O/L Relay
Short-circuit
protection *
Type 1 co-ordination as per
EN 60947-4-1 / IEC 947-4-1
380-400 V
aM fuses
16
25
32
50
63
80
100
125
160
>>
gG fuses
25
35
50
63
100
100
125
160
200
Wiring diagrams ............................................ page 2/13
Type
State control
voltage
YKA 9-30E
YKA 12-30E
YKA 16-30E
YKA 26-30E
YKA 30-30E
YKA 40-30E
YKA 50-30E
YKA 63-30E
YKA 75-30E
Control voltage code
Voltage
V 50 Hz
24
110
110 ... 115
220 ... 230
230 ... 240
380 ... 400
400 ... 415
415 ... 440
* Unsuitable for YKA 50-30E ... YKA 75-30E starters.
Order code
to be completed with
control voltage code
1SBK 142 501R8
1SBK 162 501R8
1SBK 182 501R8
1SBK 242 501R8
1SBK 282 501R8
1SBK 322 501R8
1SBK 352 501R8
1SBK 372 501R8
1SBK 412 501R8
V 60 Hz
24
110 ... 120
115 ... 120
230 ... 240
240
400 ... 415
415 ... 440
440
>>
Dimensions .................................................... page 2/14
Code
8
1
4
9
0
8
5
6
7*
00
00
00
00
00
00
00
00
00
Control circuit
must be connected
– to a separate
– or phase-to-phase
– or phase-to-neutral
supply
1SBC 0095 00 R1001
Weight
in
kg
Packing
1 piece
1.655
1.655
1.655
2.162
3.167
3.178
4.197
4.203
4.544
Y
2/11
2