E53-CNBN2 Omron, E53-CNBN2 Datasheet - Page 7

Controller Option Unit

E53-CNBN2

Manufacturer Part Number
E53-CNBN2
Description
Controller Option Unit
Manufacturer
Omron
Datasheet

Specifications of E53-CNBN2

Operating Temperature Max
55°C
Operating Temperature Min
-10°C
Temperature Accuracy ±
0.3%
Mounting Type
DIN Panel
Approval Bodies
CULus, CE
For Use With
E5CN Temperature Controller
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Input Ranges
Thermocouple/Platinum Resistance Thermometer (Universal Inputs)
Shaded settings are the default settings.
The applicable standards for the input types are as follows:
K, J, T, E, N, R, S, B: JIS C 1602-1995, IEC 584-1
L: Fe-CuNi, DIN 43710-1985
U: Cu-CuNi, DIN 43710-1985
W: W5Re/W26Re, ASTM E988-1990
Models with Analog Inputs
Shaded settings are the default settings.
Setting
number
Input specification
Setting range
Setting number
Name
Input
Type
−100.0
−200.0
2300
1800
1700
1600
1500
1400
1300
1200
1100
1000
900
800
700
600
500
400
300
200
100
0
Input Type
−200 −199.9
850
0
Platinum resistance
Pt100
500.0
thermometer
1
100.0
0.0
2
−199.9
500.0
JPt100
3
100.0
Usable in the following ranges by scaling:
−1999 to 9999, −199.9 to 999.9, −19.99 to 99.99 or −1.999 to 9.999
0
0.0
4 to 20mA
4
1300
−200
5
K
Current
500.0
−20.0 −100 −20.0
6
1
0 to 20 mA
850
7
J
400.0
8
−200 −199.9 −200
400
9
2
T
1 to 5 V
400.0
10
600
11
E
Thermocouple
−100
850
12
3
L
Voltage
0 to 5 V
−200 −199.9 −200
400
13
JPt100: JIS C 1604-1989, JIS C 1606-1989
Pt100: JIS C 1604-1997, IEC 751
PL II: According to Platinel II electromotive force charts from BASF (previously
U
400.0
14
Engelhard)
4
1300
15
0 to 10 V
N
1700 1700
16
R
0
17
S
0
1800
100
18
B
2300
24
W
0
1300
PL
25
II
0
10 to
70°C
Infrared temperature
19
90
0
E5CN/E5CN-U
60 to
120
120
20
°C
sensor
0
115
165
165
°C
21
to
0
140
260
260
22
°C
to
0
Usable
in the
following
ranges
by
scaling:
−1999 to
9999 or
−199.9
to 999.9
Analog
50 mV
input
0 to
23
7

Related parts for E53-CNBN2