XTAE007B10TD004 EATON CUTLER HAMMER, XTAE007B10TD004 Datasheet - Page 195

IEC Non-Reversing Starter

XTAE007B10TD004

Manufacturer Part Number
XTAE007B10TD004
Description
IEC Non-Reversing Starter
Manufacturer
EATON CUTLER HAMMER
Datasheet

Specifications of XTAE007B10TD004

No. Of Phases
Single Or Three
Power Rating
3.5kW
Current Rating
7A
Operating Temperature Range
-25°C To +50°C
Mounting Type
DIN Rail
Overload Adjustment Current Max
4A
Overload Adjustment Current Min
2.4A
Supply Voltage Max
24VDC
Frame Size
Standard
Combination Motor Controllers
Combination Motor Controllers
Product Description
Eaton’s XT IEC open non-
reversing and reversing
manual motor controllers
combine a manual motor
protector with an IEC
contactor(s) to provide a
complete motor protection
solution by combining motor
disconnect function, thermal
overload protection, magnetic
short-circuit protection and
remote control operation in
one compact, assembled
unit. these assembled
manual motor controllers
cover motors with FLA
ratings from 0.10A to 65A.
The UL 508 Type F labeled
combination motor controller
(CMC) includes a line side
adapter (LSA). These
assembled combination
motor controllers cover
motors with FLA ratings
from 0.10A to 65A.
Application Description
The XT IEC non-reversing
and reversing manual
and combination motor
controllers can be used in
the following applications:
Group Motor Control
Manual motor controllers
(MMCs) are ideal for group
motor applications where an
upstream breaker or fuse
provides protection for two or
more motors. XT manual
motor controllers (MMC)
combine a manual motor
protector, a wiring connector
link and IEC contactor.
Volume 5—Motor Control and Protection CA08100006E—May 2011 www.eaton.com
IEC Contactors and Starters
Contents
Description
Relays and Timers . . . . . . . . . . . . . . . . . . . . . . . . .
Miniature Controls . . . . . . . . . . . . . . . . . . . . . . . . .
Contactors and Starters . . . . . . . . . . . . . . . . . . . . .
Thermal Overload Relays . . . . . . . . . . . . . . . . . . . . V5-T27-130
C440/XT Electronic Overload Relay . . . . . . . . . . . V5-T27-143
Manual Motor Protectors . . . . . . . . . . . . . . . . . . . V5-T27-159
Combination Motor Controllers
Reference Data . . . . . . . . . . . . . . . . . . . . . . . . . . . V5-T27-218
Individual Branch Circuit for Motor Loads
Combination motor controller
(CMC), consisting of a line
side adapter, manual motor
protector, wiring connector
link and IEC contactor,
provide an efficient means to
build an entire branch circuit.
The XT CMC is UL 508 Type
F approved, meaning it is
“self-protected” and doesn’t
require the use of an
additional fuse or breaker for
short circuit protection. This
approval means CMC’s can
be used in place of a
traditional fuse-starter and
breaker-starter motor circuit.
Based around two key
functional components (MMP
and contactor), the CMC is a
very cost effective means to
build a branch circuit. Fuses
and breakers must be
oversized to prevent tripping
during motor start up, and
thus these oversized devices
can no longer protect the
motor. To compensate for
this, a motor overload relay is
necessary to protect the
motor.
Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V5-T27-196
Standards and Certifications . . . . . . . . . . . . . . . V5-T27-196
Catalog Number Selection . . . . . . . . . . . . . . . . V5-T27-197
Product Selection . . . . . . . . . . . . . . . . . . . . . . . V5-T27-197
Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . V5-T27-205
Technical Data and Specifications . . . . . . . . . . V5-T27-207
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . V5-T27-213
An Eaton
Green Solution
XT IEC Power Control
The manual motor protector
was invented in Germany by
Moeller to correct this
inefficiency. The MMP
operates similarly to a circuit
breaker, except the inrush
(magnetic) protection is set to
14 times the running current,
thus accounting for motor
start-up current without the
necessity to oversize. A
overcurrent dial was added to
the face of the MMP to serve
as the motor overload
protection. This “motor
protective circuit breaker”, as
it is referred to in Europe,
now accomplishes all four
key functions of a motor
branch circuit: disconnect,
short circuit, motor controller
and motor overload
protection. With the addition
of a contactor, users have the
ability to remotely control the
starter device.
Whether a single motor
application or a multiple
motor application, CMC’s are
an ideal solution for
machinery OEMs and panel
builders.
27.1
V5-T27-18
V5-T27-35
V5-T27-195
V5-T27-3
Page