XTAE007B10TD2P4 EATON CUTLER HAMMER, XTAE007B10TD2P4 Datasheet - Page 186

IEC Non-Reversing Starter

XTAE007B10TD2P4

Manufacturer Part Number
XTAE007B10TD2P4
Description
IEC Non-Reversing Starter
Manufacturer
EATON CUTLER HAMMER
Datasheet

Specifications of XTAE007B10TD2P4

No. Of Phases
Single Or Three
Power Rating
3.5kW
Current Rating
7A
Operating Temperature Range
-25°C To +50°C
Mounting Type
DIN Rail
Overload Adjustment Current Max
2.4A
Overload Adjustment Current Min
1.6A
Supply Voltage Max
24VDC
Frame Size
Standard
27.1
UL 508 Type E Ratings—XTPR Frame B + XTPAXLSA
Manual Motor
Protector—
Screw Terminal
Catalog Number
XTPRP16BB1
XTPRP16BC1
XTPRP25BC1
XTPRP40BC1
XTPRP63BC1
XTPR001BC1
XTPR1P6BC1
XTPR2P5BC1
XTPR004BC1
XTPR6P3BC1
XTPR010BC1
XTPR012BC1
XTPR016BC1
XTPR020BC1
XTPR025BC1
XTPR032BC1
UL 508 Type E Ratings—XTPR Frame D + XTPAXLSAD
Manual Motor
Protector—
Screw Terminal
Catalog Number
XTPR016DC1
XTPR025DC1
XTPR032DC1
XTPR040DC1
XTPR050DC1
XTPR058DC1
XTPR063DC1
Note
V5-T27-186
For UL 508 Type E applications, the manual motor protector assembly does not require a dedicated upstream protective
device in the panel, thus a maximum rating is not required.
Line Side
Adapter
Catalog Number
XTPAXLSA
XTPAXLSA
XTPAXLSA
XTPAXLSA
XTPAXLSA
XTPAXLSA
XTPAXLSA
XTPAXLSA
XTPAXLSA
XTPAXLSA
Line Side
Adapter
Catalog Number
XTPAXLSAD
XTPAXLSAD
XTPAXLSAD
XTPAXLSAD
XTPAXLSAD
XTPAXLSAD
XTPAXLSAD
XTPAXLSA
XTPAXLSA
XTPAXLSA
XTPAXLSA
XTPAXLSA
XTPAXLSA
Volume 5—Motor Control and Protection CA08100006E—May 2011 www.eaton.com
IEC Contactors and Starters
XT IEC Power Control
FLA
Adjustment
Range/Overload
Release—
I
0.1–0.16
0.16–0.25
0.25–0.4
0.4–0.63
0.63–1
1–1.6
1.6–2.5
2.5–4
4–6.3
6.3–10
8–12
10–16
10–16
16–20
20–25
25–32
FLA
Adjustment
Range/Overload
Release—
I
10–16
16–25
25–32
32–40
40–50
50–58
55–65
r
r
(Amps)
(Amps)
Short
Circuit
Release—
I
2.2
3.5
5.6
8.82
14
22.4
35
56
88.2
140
168
224
224
280
350
448
Short
Circuit
Release—
I
224
350
448
560
700
812
882
rm
rm
(Amps)
(Amps)
UL 508 Type E Application
Maximum rms Symmetrical Short-Circuit Ratings (kA)
240V
50
50
50
50
50
50
50
50
50
50
42
42
18
18
18
18
UL 508 Type E Application
Maximum rms Symmetrical Short-Circuit Ratings (kA)
240V
65
65
65
65
65
65
65
480/277V
50
50
50
50
50
50
50
50
50
50
42
42
18
18
18
18
480/277V
65
65
65
65
65
65
65
600/347V
50
50
50
50
50
50
50
50
50
50
600/347V
25
25
25
25
Maximum Upstream
Protective Device (A)
Maximum Fuse
600V
Not required
Not required
Not required
Not required
Not required
Not required
Not required
Not required
Not required
Not required
Not required
Not required
Not required
Not required
Not required
Not required
Maximum Upstream
Protective Device (A)
Maximum Fuse
600V
Not required
Not required
Not required
Not required
Not required
Not required
Not required
Maximum
Circuit Breaker
600V
Not required
Not required
Not required
Not required
Not required
Not required
Not required
Not required
Not required
Not required
Not required
Not required
Not required
Not required
Not required
Not required
Maximum
Circuit Breaker
600V
Not required
Not required
Not required
Not required
Not required
Not required
Not required

Related parts for XTAE007B10TD2P4