E53-R

Manufacturer Part Number
E53-R
Description
Temperature Controller
Manufacturer
Omron
Type
Ramp / Soak Process Controllerr
Datasheets

Specifications of E53-R

Accessory Type
Relay Output
Voltage Rating
250V
Current Rating
5A
Control Method
ON/OFF and PID Control
Display Type
7-Segment
Mounting
Horizontal Mount
Features
Modular structure, one-stock type
Input Type
Analog
For Use With
E5EK Series Controllers
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
For Use With/related Products
E5AK
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
E53R
■ Accessories (Order Separately)
Note: No CT is required unless the heater burnout alarm function is used.
Unit Label
Specifications
■ Ratings
Note: 1. All control outputs are insulated from the input circuit.
■ Input Ranges
Platinum Resistance Thermometer
Current Transformer
Terminal Cover
Model
Supply voltage
Power consumption
Operating voltage range
Input
Input impedance
Control output
Auxiliary output
Control method (See note 2.)
Setting method
Indication method
Potentiometer
Event input
Transfer output
Remote SP input
Current Transformer input
Other functions
Degree of protection
Range
Setting
Input (switch selectable)
2. Fuzzy self-tuning is available when using the Digital Controller in standard control operation with temperature input.
Name
Name
http://www.ia.omron.com/
Item
C
F
0
199.9 to 650.0
199.9 to 999.9
Y92S-L1
JPt100
E54-CT1
E54-CT3
E53-COV08
AC100 to 240V, 50/60 Hz
E5EK: 15 VA
85% to 110% of rated supply voltage
Thermocouple:
Platinum resistance thermometer: JPt100, Pt100
Current input:
Voltage input:
Current input: 150 ; Voltage input: 1 M min.
Standard Model, Programmable Model
According to Output Unit (see Output Unit Ratings and Characteristics)
Position-proportional Model
2 Relay outputs: SPST-NO, 1 A at 250 VAC (including inrush current) (See note 1.)
SPST-NO, 3 A at 250 VAC (resistive load)
ON/OFF or 2-PID control (with auto-tuning)
Digital setting using front panel keys
7-segment digital display and LEDs
100
Contact input:
No-contact input: ON: residual voltage: 1.5 V max., OFF: leakage current: 0.1 mA max.
4 to 20 mA, permissible load impedance: 600
Current input: 4 to 20 mA (Input impedance: 150 )
Connect an exclusive Current Transformer (E54-CT1 or E54-CT3)
Standard
Manual output, heating/cooling control, SP limiter, loop burnout alarm, SP ramp, MV limiter, MV
change rate limiter, input digital filter, input shift, run/stop, protect functions, scaling function.
Option
Multiple SP, run/stop selection, transfer output functions
Conforms to IEC IP66 and NEMA4 (Indoor use)
1
to 2.5 k
199.9 to 650.0
199.9 to 999.9
Pt100
AC100-240V type
Model
Model
ON: 1 k max., OFF: 100 k min.
K, J, T, E, L, U, N, R, S, B, W, PLII
4 to 20 mA, 0 to 20 mA
1 to 5 V, 0 to 5 V, 0 to 10 V
(c)Copyright OMRON Corporation 2007 All Rights Reserved.
5.8 mm
12.0 mm
E5EK
max., resolution: approx. 2,600
AC/DC24V, 50/60 Hz
12 VA, 8 W
Connectable models
Hole diameter
AC/DC24V type
E5EK