FL1B-M08B2R2 IDEC, FL1B-M08B2R2 Datasheet - Page 9

Programmable Logic Controller

FL1B-M08B2R2

Manufacturer Part Number
FL1B-M08B2R2
Description
Programmable Logic Controller
Manufacturer
IDEC
Datasheet

Specifications of FL1B-M08B2R2

Accessory Type
Digital I/O Module
Voltage Rating
24VDC
Current Rating
140mA
Length
90mm
External Width
35.5mm
External Depth
58mm
Signal Input Type
DC
Output Type
Relay
Supply Voltage Max
24VDC
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
For Use With
Works Only W/ SmartRelay FL1B CPU Unit
64
Expansion I/O Module Part Number
Wire Length
Output
Output Points/
Contact Confi guration
Isolation
Dielectric Strength
(between power/input terminals
and output terminals)
Output Voltage
Maximum Load Current
Short-circuit Protection
Minimum Switching Load
Initial Contact Resistance
Mechanical Life
Electrical Life
Analog Output Points
Analog Output Range
Digital Resolution
Output Error
Output Impedance
Analog Value Conversion
Interval
Wire Length
Mechanical Load
Electrical Load
Resistive Load/Lamp Load
Inductive Load
IDEC SmartRelay Series
FL1B-M08B1S2
100 m
Transistor source
4 points (separate)
External power
voltage
(20.4 to 28.8V DC)
0.3A
Built-in current
limiting
resistor: Approx. 1A
10Hz
10Hz
0.5Hz
FL1B-M08B2R2
100 m
Relay
4NO contacts
Isolated
2500V AC, 1 minute
Resistive load
5A at 12/24V AC/DC
5A at 100/120V AC
5A at 230/240V AC
Inductive load
2A at 12/24V AC/DC
3A at 100/120V AC
3A at 230/240V AC
External fuse
required:
16A maximum
10mA, 12V DC
100 mΩ maximum
(at 1A, 24V DC)
10 million operations
(no load, 10Hz)
100,000 operations
(rated resistive load)
1800 operations/hour
10Hz
2Hz
0.5Hz
500V DC, 1 minute
www.idec.com
FL1B-M08D2R2
100 m
Relay
4NO contacts
Isolated
2500V AC, 1 minute
Resistive load
5A at 12/24V AC/DC
5A at 100/120V AC
5A at 230/240V AC
Inductive load
2A at 12/24V AC/DC
3A at 100/120V AC
3A at 230/240V AC
External fuse
required:
16A maximum
10mA, 12V DC
100 mΩ maximum
(at 1A, 24V DC)
10 million operations
(no load, 10Hz)
100,000 operations
(rated resistive load)
1800 operations/hour
10Hz
2Hz
0.5Hz
500V DC, 1 minute
FL1B-M08C2R2
100 m
Relay
4NO contacts
Isolated
2500V AC, 1 minute
Resistive load
5A at 12/24V AC/DC
5A at 100/120V AC
5A at 230/240V AC
Inductive load
2A at 12/24V AC/DC
3A at 100/120V AC
3A at 230/240V AC
External fuse required:
16A maximum
10mA, 12V DC
100 mΩ maximum
(at 1A, 24V DC)
10 million operations
(no load, 10Hz)
100,000 operations
(rated resistive load)
1800 operations/hour
10Hz
2Hz
0.5Hz
500V DC, 1 minute
Programmable Logic Controllers
FL1B-J2B2
10 m (twisted-pair
shielded cable)
FL1D-K2B2
Analog
Yes
2
0 to 10V
10 bits (0 to
1000V)
±2.5% (of full
scale)
5kΩ
50ms
10 m (twisted-
pair shielded
cable)

Related parts for FL1B-M08B2R2