PS31 Omron, PS31 Datasheet - Page 6

no-image

PS31

Manufacturer Part Number
PS31
Description
ELECTRODE HOLDER
Manufacturer
Omron
Datasheet

Specifications of PS31

Accessory Type
Electrode Holder
Length
75mm
Svhc
No SVHC (15-Dec-2010)
External Depth
29.5mm
External Length / Height
1m
No. Of Input Channels
3
No. Of Channels
3
Rohs Compliant
Yes
For Use With
Water Supply And Drainage Control In Buildings
Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
PS3102
Manufacturer:
WOLFSONM
Quantity:
4 800
Part Number:
PS3120A
Manufacturer:
PS
Quantity:
20 000
■ Electrode Holder Precautions
Precautions for Correct Use
• Never mount the Electrode Holder horizontally. Mounting the
• The resin may become discolored after long-term use or storage.
• When wiring the BF, use M6 crimp terminals.
• Do not pull on the cable.
• Disconnect the wiring with the Level Controller before inspecting
• Use OMRON 61F Floatless Switches for control devices.
• Consult with your OMRON representative before using the BF in
Precautions for Tightening Torque and Work
Note: 1. A gasket is supplied with the BS-1. A gasket is not required
• Always use an F03-11 Protective Cover if the BF-3 (-5) is used
BS-1
(See
note 1.)
BS-1T
(See
note 1.)
Electrode Holder horizontally may cause liquid to leak from the
Electrode Holder and result in 61F reset failure.
This is normal and does not present any problems in using the
product.
Electrode Holders.
any liquid other than water.
outdoors or in locations subject to water, dust, dirt, or other foreign
matter. Foreign matter adhering to the electrode insulators may
cause incorrect operation due to leaking.
2. Wind commercially available sealing tape two or three times
3. When installing the wiring, secure nut 2 with a wrench so
to mount the BS-1T. (One is not supplied.)
around the M18 screw section before tightening the screws.
that no force is applied to the terminal bolt, and complete the
tightening with nut 1 (as in the following figure). If nut 2 is not
secured, the load on the terminal bolt may cause leakage of
steam and pressure.
Wire installation section (M4) (See note 3.)
Electrode Holder installation section (M18)
(See note 2.)
Wire installation section (M4) (See note 3.)
Electrode Holder installation section (M18)
(See note 2.)
Terminal bolt
Wire
ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.
To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.
http://www.ia.omron.com/
In the interest of product improvement, specifications are subject to change without notice.
Crimp terminal
1
2
6500.0 N·cm
137.2 N·cm
137.2 N·cm
196.1 N·cm
(c)Copyright OMRON Corporation 2007 All Rights Reserved.