UEP-3.3/6000-D48-C Murata Power Solutions Inc, UEP-3.3/6000-D48-C Datasheet - Page 2

DC/DC TH 6A 48-3.3V UEP

UEP-3.3/6000-D48-C

Manufacturer Part Number
UEP-3.3/6000-D48-C
Description
DC/DC TH 6A 48-3.3V UEP
Manufacturer
Murata Power Solutions Inc
Series
UEPr

Specifications of UEP-3.3/6000-D48-C

Product
Isolated
Output Power
20 W
Input Voltage Range
36 V to 75 V
Number Of Outputs
1
Output Voltage (channel 1)
3.3 V
Output Current (channel 1)
6 A
Isolation Voltage
1.5 KV
No. Of Outputs
1
Input Voltage
36V To 75V
Power Rating
19.8W
Output Voltage
3.3V
Output Current
6A
Approval Bodies
EN / UL
Supply Voltage
48V
Dc / Dc Converter Case Style
Through Hole
Rohs Compliant
Yes
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Optional Functions
UEP converters are designed such that the 12 and 15V
configured for either positive logic on/off control (no suffix) or negative logic
(“N” suffix). 3.3 and 5V
No Suffix On/Off Control function (positive polarity) on pin 3
N
PART NUMBER STRUCTURE
Typical at TA = +25°C under nominal line voltage and full-load conditions, unless otherwise noted.
Ripple/Noise (R/N) is tested/specifed over a 20MHz bandwidth. All models are specified with no
external input/output capacitors.
Output Configuration:
UEP-3.3/4500-D12
UEP-3.3/4500-D24
UEP-3.3/4500-D48
UEP-3.3/6000-D48
UEP-5/3500-D12
UEP-5/3500-D24
UEP-5/3500-D48
UEP-5/6000-D48
UEP-12/1400-D12
UEP-12/1400-D24
UEP-12/1400-D48
UEP-15/1200-D12
UEP-15/1200-D24
U = Unipolar
Nominal Output Voltage:
On/Off Control function (negative polarity) on pin 3.
(12V and 15V models only.)
3.3, 5, 12 or 15 Volts
External Pinout
U
OUT
EP
models are available with positive logic only (no suffix).
3.3
3.3
3.3
3.3
12
12
12
15
15
OUT
-
5
5
5
5
3.3
/
4500
4500
4500
6000
3500
3500
3500
6000
1400
1400
1400
1200
1200
OUT
4500
Maximum Output Current
in mA
-
Input Voltage Range:
D48
85
85
85
85
85
85
85
85
85
85
85
85
85
D12 = 10-18 Volts (12V nominal)
D24 = 18-36 Volts (24V nominal)
D48 = 36-75 Volts (48V nominal)
www.murata-ps.com
OUT
N Suffix
N C
models can be
Available for 12V
and 15V
-
100
100
100
100
100
100
100
100
100
100
100
100
100
OUT
ROHS-6
Models
Hazardous
Substance
Compliance
±0.2%
±0.2%
±0.2%
±0.2%
±0.2%
±0.2%
±0.2%
±0.2%
±0.2%
±0.2%
±0.2%
±0.2%
±0.2%
OUT
±0.5%
±0.5%
±0.5%
±0.3%
±0.5%
±0.5%
±0.5%
±0.3%
±0.5%
±0.5%
±0.5%
±0.5%
±0.5%
Ultra-High Density, 2" x 1", 1.2-6 Amp,15-30 Watt DC/DC’s
MECHANICAL SPECIFICATIONS
Load regulation is specified over no load to 100% load conditions for 3.3 and 5V
100% load conditions for 12 and 15 V
Nominal line voltage, no-load/full-load conditions.
Pin
1
2
3
4
5
6
IN
Single Output UEP Models
12
24
48
48
12
24
48
48
12
24
48
12
24
Function P21
+Input
–Input
On/Off Control
+Output
–Output
Trim
Technical enquiries email: sales@murata-ps.com, tel:
10-18
18-36
36-75
36-75
10-18
18-36
36-75
36-75
10-18
18-36
36-75
10-18
18-36
Case C15
OUT
models.
120/1760
80/1490
60/1650
60/1760
50/730
35/360
40/470
65/850
40/430
35/710
45/800
20/400
45/860
Dimensions are in inches (mm shown for ref. only).
OUT
Components are shown for reference only.
Tolerances (unless otherwise specified):
.XX ± 0.02 (0.5)
.XXX ± 0.010 (0.25)
Angles ± 2˚
MDC_UEP Models.B02 Page 2 of 11
83.5%
85.5%
85.5%
82.5%
82.5%
86%
84%
86%
86%
88%
85%
85%
85%
Third Angle Projection
84.5%
87.5%
87.5%
88%
86%
88%
88%
91%
85%
87%
87%
85%
87%
OUT
+1 508 339 3000
models, 25mA to
C15, P21
C15, P21
C15, P21
C15, P21
C15, P21
C15, P21
C15, P21
C15, P21
C15, P21
C15, P21
C15, P21
C15, P21
C15, P21

Related parts for UEP-3.3/6000-D48-C