Voltage Regulator/Power Conditioner

63-23-220-8

Manufacturer Part Number
63-23-220-8
Description
Voltage Regulator/Power Conditioner
Manufacturer
SOLA HEVI DUTY
Series
MCRr
Datasheets

Specifications of 63-23-220-8

Suppressor Type
Power Line Conditioner
Input Voltage
480VAC
Output Voltage
120V
Width
330.2mm
Height
457.2mm
Output Voltage 3
240V
Output Type
Fixed
External Height
18"
Output Power
2000 VA
Input Voltage (nominal)
480 V
Features
Harmonic Filtering
Mounting Type
Surface Mount
Voltage Regulation
+/- 3 %
Voltage Regulation Accuracy
+/- 3 %
Brand/series
Hardwired Series
Capacity
2000 VA
Length
17.58 in.
Outline
B
Weight
109 lbs.
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Selection Tables: Single Phase
Group 3 – MCR Series, 60 Hz Only
Group 4 – MCR Series, 50 Hz Only (±5% output voltage regulation)
Specifications
Voltage
Current
Frequency
Line Regulation
Overload Protection
Output Harmonic Distortion
Noise Attenuation
Efficiency
Storage Temperature
Operating Temperature
Audible Noise
Approvals
Warranty
Notes: 1 - Consult user manual for fuse sizing.
15000
10000
15000
10000
1000
2000
3000
5000
7500
1000
2000
3000
5000
7500
500
120
250
500
VA
VA
2 - It is recommended that the unit run at a minimum of 40-50% load.
1
Parameter
63-23-612-8
63-23-625-8
63-23-650-8
63-23-710-8
63-23-720-8
63-23-730-8
63-23-750-8
63-28-775-8
63-28-810-8
63-28-815-8
63-31-150-8
63-32-210-8
63-32-220-8
63-32-230-8
63-29-250-8
63-29-275-8
63-29-310-8
63-29-315-8
Catalog Number
Catalog Number
110, 120, 220, 240, 380, 415
110, 120, 220, 240, 380, 415
110, 120, 220, 240, 380, 415
110, 120, 220, 240, 380, 415
110, 120, 220, 240, 380, 415
110, 120, 220, 240, 380, 415
110, 120, 220, 240, 380, 415
Continuous at full load (lower input voltage possible at lighter load)
208, 240, 480, 600
208, 240, 480, 600
208, 240, 480, 600
208, 240, 480, 600
Voltage Input
220, 240, 380, 415
220, 240, 380, 415
220, 240, 380, 415
Contact Technical Services at (800) 377-4384 with any questions.
See Operating Characteristics section for details.
Voltage Input
600
600
600
600
at Full Load & 80% of nominal input voltage
See General Information section for details
V
Humidity <95% non-condensing
Humidity <95% non-condensing
in
At full load within input range
For temporary surge or sags
>80% and <110% of nominal
At Nominal Input Voltage
Visit our website at www.solaheviduty.com.
Full Resistive Noise
Transverse Mode
Common Mode
60 Hz Models
50 Hz Models
At Full Load
Condition
Power Protection and Conditioning
120, 208, 240
120, 208, 240
120, 208, 240
120, 208, 240
120, 208, 240
120, 208, 240
120, 208, 240
120, 208, 240
Voltage Output
110, 120, 220, 240
110, 120, 220, 240
110, 120, 220, 240
110, 120, 220, 240
110, 120, 220, 240
110, 120, 220, 240
110, 120, 220, 240
110, 120, 220, 240
110, 120, 220, 240
110, 120, 220, 240
Voltage Output
General
Output
Input
Height
(inch)
13
17
18
19
28
27
28
28
Height
(inch)
11
13
18
18
27
30
28
30
30
9
Width
(inch)
13
13
13
25
25
38
9
9
Width
(inch)
13
13
13
26
26
38
6
6
9
9
± 5% for 50 Hz units, ± 3% for 60 Hz units
Depth
(inch)
Current limited at 1.65 times rated current
10
10
10
10
10
10
7
7
50 Hz or 60 Hz depending on model
Depth
(inch)
UL1012, CSA evaluated by UL
10
10
10
10
10
10
8
8
7
7
+10% to -20% of nominal
+20% to -35% of nominal
I
in
3% total RMS content
≅ (VA/.89)/(V
35 dBA to 65 dBA
Ship weight
CE (EMC & LVD)
-20° to +85°C
-20° to 50°C
10 + 2 Years
Up to 92%
(lbs)
109
142
221
360
441
706
Ship weight
120 dB
38
62
60 dB
Value
(lbs)
113
162
266
393
490
776
24
27
40
64
in
x 80%)
Design
Style
Design
1
1
1
1
1
2
2
3
Style
1
1
1
1
1
1
1
2
2
3
Conn
Elec
Conn
Elec
B
B
B
B
C1
C2
C2
A
A
A
A
C
C
C
C
C
C
C
37