RM0008N50 HAMMOND POWER SOLUTIONS, RM0008N50 Datasheet - Page 16

no-image

RM0008N50

Manufacturer Part Number
RM0008N50
Description
Line Reactor
Manufacturer
HAMMOND POWER SOLUTIONS
Series
RMr
Datasheet

Specifications of RM0008N50

Suppressor Type
Line Reactor
Power Consumption
31W
Supply Voltage Range
240VAC To 600VAC
Phase Type
3 Phase
Output Current
8A
Inductance
5mH
Switching Frequency
20kHz
Length
86.11mm
Width
111.76mm
Brand/series
RM Series
Current, Rating
8 A
Frequency, Operating
60 Hz
Impedance
5%
Power, Rating
1.5 HP
Standards
UL File No.: E61431, CSA File No.: LR 3902 and CE Mark (IEC 61558- 2-20-2000:)
Voltage, Rating
240 VAC
Height
86.36mm
Power Rating
3hp
Rohs Compliant
Yes
Supply Voltage
600V
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
SECTION 3
TYPICAL “RC” DV/DT FILTERS PERFORMANCE
a fi lter which reduces dv/dt and peak voltages from the PWM voltage waveform. This combined with a 3%
impedance reactor, that will reduce motor heating harmonics, will signifi cantly increase the life of the motor.
bus voltage, and higher. Therefore motor terminal voltage peaks of 1200 volts for 480V drives and 1600 volts for
600V drives are not uncommon. The highest peak voltages will typically occur in lower HP applications.
Standard “RC” DV/DT Filter Specifi cations
RATINGS:
Nominal Inductance +/- 10% @ rated current.
95% of nominal inductance @ 150% rated current.
50% of nominal inductance @ 350% of rated current.
The above performance indicates that even at
very substantial overload conditions (even beyond
what other equipment in the circuit could tolerate),
the RM Line Reactor will still provide current
limiting performance against total harmonic distortion
generated by the drive system.
OVERLOAD:
150% rated 60 Hz current overload continuous.
TEMPERATURE RISE:
115° C on units up to 160 amps; average ambient
of 40°C.
115° C on units larger than 160 amps; average
ambient of 60° C.
INSULATION SYSTEM:
200° C Temperature Class up to 160 amps,
220° C Temperature Class over 160 amps.
FREQUENCY:
60 Hz Fundamental Current Maximum.
© Hammond Power Solutions Inc.
The RC series DV/DT fi lters combine appropriate values of inductance, capacitance and resistance to form
Long lead length motor drive applications can experience motor terminal peak voltage spikes twice the DC
125
COOLING METHOD:
Natural convection
SYSTEM VOLTAGE:
600 Volts Maximum
APPROVALS:
UL File No.: E61431
CSA File No.: LR 3902
SOUND LEVEL:
ENCLOSURE: (when specifi ed)
NEMA 2 or NEMA 3R
HARMONIC WITHSTAND:
Hammond dv/dt fi lters are designed to withstand
harmonics associated with the output side of variable
speed drives including IGBT type inverters.
SWITCHING FREQUENCY:
2.5 KHz up to 20 KHz.
RC SERIES DV/DT FILTERS
2 to 18 amps:
130 to 320 amps:
25 to 100 amps:
400 to 600 amps:
Data subject to change without notice.
58 dBA
70 dBA
64 dBA
75 dBA