DIN3-165-120-L1 SUPERIOR ELECTRIC, DIN3-165-120-L1 Datasheet

DIN Rail Mounted Surge Suppressor

DIN3-165-120-L1

Manufacturer Part Number
DIN3-165-120-L1
Description
DIN Rail Mounted Surge Suppressor
Manufacturer
SUPERIOR ELECTRIC
Series
DIN3-165r
Datasheet

Specifications of DIN3-165-120-L1

Suppressor Type
Data Line
Voltage Rating
120VAC
Operating Voltage Range
120VAC To 240VAC
Peak Surge Current
165kA
Connector Type
Screw Terminal
Frequency Max
64Hz
DIN3-165 Series STABILINE® Transient Voltage Surge Suppressors are single pole, parallel and/or “in-line” connected, MOV technology
Class I, Category C Surge Protective Devices suitable for use in AC electrical power systems for protection against surge and transient activity.
DIN3-165 Series protectors provide 165 or 100 kA Surge Amp Capacity in a maintenance free, low profi le, DIN Rail mountable module. All line
voltage protectors (L-In / L-Out) can also be connected “in-line” and provide for 50A Maximum Continuous Operating Current protection.
1
2
3
TYPICAL SERVICE CONFIGURATIONS for Parallel-Connected Method
Contact Factory for addititional confi gurations
DIN3-165-120-L1
DIN3-165-220-L1
DIN3-165-277-L1
DIN3-165-480-L1
F
V
For a minimum of (20) 8 x 20usec surges
UL 1449 2nd Edition, (6kV, 500A 8 x 20usec) Surge Voltage Rating
C3 Combination Wave, 20kV, 8 x 20usec, 10 kA
DIN3-100-NG1
Thank you for purchasing the DIN3-165 Series STABILINE
Transient Voltage Surge Suppressor ... another Superior product!!
Expect exceptional performance. The unit is built to the highest
standards for your complete satisfaction.
To assure many years of uninterrupted service, please read this
Owners Manual to familiarize yourself with the operation and
proper installation of the DIN3-165 Series unit.
STABILINE
M
In
Model
F
V
L
Out
M
1 Ø, 2-Wire, w/ground
F
V
F
V
C
M
M
In
F
V
MODEL NUMBER & Typical System Voltage / Service Confi gurations
L
STABILINE® Transient Voltage Surge Suppressors
1
120, 120/240, 220, 277, 380, 480 VAC Neutral to Ground
Out
M
1 Ø, 120/240 VAC, 3-Wire SPLIT-PHASE, w/ground
F
V
F
V
3 Ø, 208Y/120 VAC, 4-Wire WYE, w/ground
3 Ø, 380Y/220 VAC, 4-Wire WYE, w/ground
3 Ø, 480Y/277 VAC, 4-Wire WYE, w/ground
System Voltage / Service Configuration
1 Ø, 480 VAC, 2-Wire, w/grounded neutral
C
M
M
In Out
F
V
3 Ø, 220 or 240 VAC, 3-Wire DELTA
3 Ø, 380 or 480 VAC, 3-Wire DELTA
In Out
N
L1
1 Ø, 120 VAC, 2-Wire, w/ground
1 Ø, 220 VAC, 2-Wire, w/ground
1 Ø, 277 VAC, 2-Wire, w/ground
M
F
V
F
V
DIN3-165 Series - OWNERS MANUAL
C
M
M
In
F
V
L
Typical
3 Ø, 4-Wire WYE, w/ground
2
Out
M
F
V
3 Ø, 3-Wire DELTA
F
V
F
V
C
M
M
M
In
F
V
F
V
In Out
L
L2
1
Out
F
V
M
M
F
V
V
F
M
In
F
V
C
C
M
M
L
3
Out
M
1 Ø, 120/240 VAC, 3-Wire
SPLIT-PHASE, w/ground
F
V
F
V
C
F
V
M
M
In
F
L-N / L-N / L-N, N-G
L-N / L-N / L-N, N-G
L-N / L-N / L-N, N-G
V
M
L
Protection Mode
F
V
In Out
2
L-N / L-N, N-G
L2
L-L / L-L / L-L
L-L / L-L / L-L
Out
M
L-N, N-G
L-N, N-G
L-N, N-G
L-N, N-G
V
M
F
F
V
N-G
C
M
C
M
In Out
N
Protector Quantity
Voltage
Line
N/A
1
2
3
1
3
3
1
3
1
3
In Out
N
N-G
N/A
N/A
1
1
1
1
1
1
1
1
1
150 VAC
330 VAC
330 VAC
550 VAC
600 VAC
MCOV
SPECIFICATIONS
Electrical Specifi cations
Environmental Specifi cations
Mechanical Specifi cations
General Specifi cations
* These INSTRUCTIONS are subject to change
Modes of Protection: L-N; L-G; L-L protectors use MOV
technology and N-G protector use Gas Tube.
Line Voltage Protectors: Multi-redundant protection
circuit (triple stage fault indicators).
Input Power Frequency: 47-64 Hz.
Associated Fusing: DIN3-165 protectors incorporate an
internal thermal disconnect system with time-delayed
Class J,30A-125A over current fuses.
Operating Temperature: -40° C to 85° C (-40° F to 185° F).
Relative Humidity: 5% to 95% non-condensing.
Max. Operating Altitude: 4,000 meters (13,000 feet).
Enclosure: IP20 enclosures (UL94V0 thermoplastic
housing material).
Mounting: Din Rail 35mm symmetrical.
Connection Method: Screw terminal # 2-10 AWG.
Size (H x W x D): 3.5 x 1.42 x 2.63 inches (90.0 x 36.0 x 67 mm).
Weight (Shipping): 0.80 lbs (0.35 kg).
Standards Compliance and Safety Approvals: Meet UL
1449, 2nd Edition, EN61643-11 (Europe), ANSI/IEEE
C62.41-2002, NF EN 61643-11 (France), VDE0675-6,
CSA-22.2 and CE marked.
Warranty: Ten Years.
without notice.
Current Rating
Max Surge
165 kA
165 kA
165 kA
165 kA
100 kA
Surge Performance Specifications
Nominal Surge
Current Rating
70 kA
70 kA
70 kA
70 kA
50 kA
1
SVR Rating
1500 VAC
500 VAC
900 VAC
900 VAC
800 VAC
UL 1449
2
C3 Comb
1750 VAC
625 VAC
950 VAC
950 VAC
Wave
----
3

Related parts for DIN3-165-120-L1

DIN3-165-120-L1 Summary of contents

Page 1

... MODEL NUMBER & Typical System Voltage / Service Confi gurations STABILINE Typical Model System Voltage / Service Configuration 1 Ø, 120 VAC, 2-Wire, w/ground DIN3-165-120-L1 1 Ø, 120/240 VAC, 3-Wire SPLIT-PHASE, w/ground 3 Ø, 208Y/120 VAC, 4-Wire WYE, w/ground 1 Ø, 220 VAC, 2-Wire, w/ground DIN3-165-220-L1 3 Ø, 380Y/220 VAC, 4-Wire WYE, w/ground 3 Ø ...

Page 2

... The DIN3-165 Series unit should be installed down stream of a 200 A maximum fuse or breaker (see diagram). If pre-existing fuses or breakers are present, then the fusing or breaker used for the DIN3-165 protector should have a lower rating in order to be properly coordinated, as per applicable electrical regulatory standards. The Short Circuit current rating for these DIN3-165 protectors are 25,000 Amps using a 50A Class J time delayed fuse ...

Related keywords