TSP 180-148 TRACOPOWER, TSP 180-148 Datasheet - Page 6

PSU, METAL, 192W, 48V/4A

TSP 180-148

Manufacturer Part Number
TSP 180-148
Description
PSU, METAL, 192W, 48V/4A
Manufacturer
TRACOPOWER
Datasheet

Specifications of TSP 180-148

Power Supply Type
Switch Mode
Power Supply Output Type
Fixed
No. Of Output Channels
1
Input Frequency
63Hz
Output Voltage
48V
Output Current
4A
Power Rating
180W
Input Voltage
85VAC To 132VAC / 87VAC
No. Of Outputs
1
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
http://www.tracopower.com
With this module and two power supplies of the TSP series (of same type) a highly
reliable, truly redundant power system can be configured without any additional
components. This module enforces the equivalent sharing of the output current by
each power supply. The system is fully redundant and provides output power even
if one power supply has completely failed e.g. by short circuit on the output. In the
event of either power supply failing or being disconnected, the second unit will
automatically supply the full current to the load. The redundancy of the system is
monitored and if lost, indicated by an alarm output. The inputs are hot swappable
and can be loaded up to 15 A each.
Function Diagram
Power
Supplies
TSP–REM360­ Redundancy Module
Specifications
Operating temperature
Electromagnetic compatibility
Redundancy OK signal (Alarm)
Dimensions
Remote link cable (0.5m)
Remote On/Off
Installation instructions
Models
Models
(includes terminal plugs)
TSP
TSP
TSP–REM360­
TSP–REM60­0­
Order Code
DC IN 1
DC IN 2
Remote
Link 1
Remote
Link 2
+
_
+
_
J1.2
J1.1
J3.1
J3.2
J1.4
J1.3
J4.1
J4.2
Alarm
J5.1
REM Controller
J5.2
Redundancy
2 x Control input
ok
2 x 24 VDC
Remote On/Off
Input
Volt adjust
J5.3
J5.4
J2.3
J2.4
J2.1
J2.2
+
_
Output
Load
Max Power
2 x 360 W
2 x 600 W
per Input
Connector Positions
Front view
DC IN 1
- - + +
– 25 °C to 70 °C max. (–13 °F...+158 °F)
derating above 40 °C (104 °F): 1.5 %/K
in correspondence to connected units (no internal
switching device)
trigger threshold at 18...22VDC,
contact open if both inputs failed
see page 10
2 cables included with TSP-REM360 module
by ext. contact: contact open = On, contact closed = Off
www.tracopower.com/products/tsp-rem_inst.pdf
Output
- + - +
Industrial Power Supplies
TSP Series
DC IN 2
Output Voltage
(24–27 VDC)
Remote On/Off
24 VDC
adjust.
Alarm
Bottom view
Output Power
Remote Link 2
Remote Link 1
90­–60­0­ Watt
360­ W
60­0­ W
max.
Page 6 of 3
Top view

Related parts for TSP 180-148