Specifications of SMART750XLA

Capacity (va / W)
750VA / 500W
No. Of Outlets
8
Input Voltage
100V AC / 110V AC / 120V AC
Output Voltage
120V
Backup Time - Full Load
10min
Length
350.52mm
Width
170.18mm
Height
256.54mm
Weight
33.9lb
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
External battery pack
compatibility
DC system voltage
(VDC)
Battery recharge rate
(included batteries)
Replacement battery
cartridge (internal UPS
battery replacement)
Battery Access
VOLTAGE REGULATION
Voltage regulation
description
Overvoltage correction
Undervoltage
correction
LEDS ALARMS & SWITCHES
LED Indicators
Alarms
Switches
SURGE / NOISE SUPPRESSION
UPS AC suppression
joule rating
EMI / RFI AC noise
suppression
AC suppression
response time
Dataline suppression
PHYSICAL
Installation form
factors supported with
included accessories
Primary form factor
UPS / Power Module
dimensions in primary
form factor (height x
width x depth / inches)
UPS / Power Module
dimensions in primary
form factor (height x
width x depth / cm)
UPS / Power Module
weight (lbs)
UPS / Power Module
weight (kg)
BP24V15RT2U
24
Less than 4.5 hours from 10% to 90%
RBC24-SLT
Supports battery access and hot-swap replacement without powering connected equipment off
Automatic Voltage Regulation (AVR) circuits maintain clean, regulated computer-grade 120, 110, 100V nominal
output, without using battery power, during brownouts 95V (120V), 87V (110V), 83V (100V)
Input voltages between 127 and 145V (120V), 116 and 133 (110V), 111 and 121 (100V) are reduced by 12%
Voltage boost of 14% applies when input is 95 to 108 (120v), 87 to 99 (110v), 83 to 90 (100v)
9 LEDs indicate line power, battery power, AVR, overload and replace battery status - with a 3-LED level meter for
load and battery charge level
Audible alarm warns of power failure condition
Includes two pushbutton switches for on/off power control and self-test/ alarm cancel functions. Also includes two
dipswitch controls for setting the nominal voltage
570 joules
Yes
Instantaneous
Includes 8-wire RJ45 jack; pins 1, 2, 3 and 6 provide 10baseT Ethernet line surge suppression with 7.5V clamping;
pins 4 and 5 provide single-line tel/DSL line surge suppression starting at 260V
Tower
Tower
10.1 x 6.7 x 13.8
25.7 x 17 x 35.1
33.9
15.4
(limit 1);
BP24V28-2U
(limit 1);
BP24V70-3U
(multi-pack compatible)