PAH50S48-24 TDK Corporation, PAH50S48-24 Datasheet - Page 22

no-image

PAH50S48-24

Manufacturer Part Number
PAH50S48-24
Description
POWER SUPPLIES
Manufacturer
TDK Corporation
Datasheet

Specifications of PAH50S48-24

Rohs Compliant
YES

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
PAH50S48-24
Manufacturer:
LAMBDA
Quantity:
292
Part Number:
PAH50S48-24
Quantity:
60
Part Number:
PAH50S48-24/V
Manufacturer:
LAMBDA
Quantity:
492
CC-E
09XX
10XX
KWD
PAE
PAF
PAH
PAQ
PF-A
PMH
3101
KWS
PFE
PH
CE-
CE-
CE-
KS
B-164
PAH
(*10) Heatsink has to be chosen according to application notes.
ITEMS/UNITS
Function
Environment
Isolation
Standards Safety Standards
Mechanical
Output
(*1) Combination output power for both channel.
(*2) At 24 VDC, Vo1 @ 15A, Vo2 @ 0A and baseplate temperature = +25℃.
(*3) Additional external components have to be connected;
(*4) Measured at Tbp=25℃, Vin=24VDC and with external components connected;
(*5) 18 - 36 VDC with respect to nominal input line 24V;
(*6) No load - full load with respect to 50% of max. load;
(*7) Current limiting with automatic recovery.
(*8) CNT reset or manual reset.
(*9) Refer to application notes.
Input
Refer to application notes.
Refer to basical connection drawing. For all of temperature range, please
refer to the application note.
constant load;
baseplate temperature = +25℃.
other output : no load ; constant input voltage;
baseplate temperature = +25℃.
Voltage Range
Efficiency (typ)
Current (typ)
Nominal Voltage
Minimum Current
Maximum Current
Maximum Power
Voltage Setting Accuracy (*2) %
Maximum Line Regulation (*5) mV
Maximum Load Regulation (*6) mV
Temperature Coefficient
Maximum Ripple & Noise (*4) mVp-p
Voltage Adjustable Range (*3)
Over Current Protection (*7)
Over Voltage Protection (*8)(*9)
Over Temperature Protection
Remote Sensing
Remote ON/OFF Control (*9)
Parallel Operation
Series Operation
Operating Temperature
Storage Temperature
Operating Humidity
Storage Humidity
Vibration
Shock
Cooling
Withstand Voltage
Isolation Resistance
Weight
Size (W x H x D)
75D24
(*10)
MODEL
(*2) %
(*2) A
(*1) W
VDC
%RH
%RH
mm
PAH75D24 Specifications
CH
V
A
A
g
105-165%
Vo2@0A
More than 100MOHM at 25℃ and 70 %RH, Output - Baseplate : 500 VDC
Input - Output : 1.5kVDC, Input - Baseplate : 1.5kVDC (20mA) for 1 min
100
3.3
1
PAH75D24-3325
Approved by UL60950-1, CSA C22.2 No.60950-1, EN60950-1.
-40 to +100 (Baseplate) Ambient temperature min = -40℃
-40 to +100 (Baseplate) Ambient temperature min = -40℃
0.825mm constant (maximum 49.0m/s²) X, Y, Z 1 hr each
Inverter shutdown (Option available : Refer to option table)
Po1+Po2=60
Negative logic (Option available : Refer to option table)
115-140%
At no operating, 10 - 55HZ amplitude (sweep 1 min)
±16.5
±6.6
2.71
76
Shutdown ; Auto restart when unit cool down
57.9 x 12.7 x 61 (Refer to outline drawing)
Output - Baseplate : .500VDC for 1 min
105-165%
Vo1@5A
Option table:
Example:
PAH75D24-3325/PV: Represent positive logic & OVP auto-restart.
Standard
30 - 95 (No dewdrop)
30 - 95 (No dewdrop)
Option
/PV
/P
/V
2.5
75
2
Conduction cooled
DC18 - 36
ON/OFF Logic
L
H
L
H
:
:
±10%
:
:
196.1
ON, H
ON, H
0.02
Negative
Negative
± 2
OFF, L
OFF, L
Positive
Positive
0.0
15
80
-
-
-
・All specifications are subject to change without notice.
:
:
:
:
OFF
OFF
ON
ON
105-165%
125-145%
Vo2@0A
±25
±10
1
5
PAH75D24-5033
Po1+Po2=75
3.91
100
Shut-down
Auto-restart
80
Shut-down
OVP
105-165%
115-140%
Vo1@5A
±16.5
±6.6
3.3
2

Related parts for PAH50S48-24