106-P30 2A ETA, 106-P30 2A Datasheet

CIRCUIT BREAKER, THERMAL, 1P, 250V, 2A

106-P30 2A

Manufacturer Part Number
106-P30 2A
Description
CIRCUIT BREAKER, THERMAL, 1P, 250V, 2A
Manufacturer
ETA
Datasheet

Specifications of 106-P30 2A

Voltage Rating Vdc
48V
Voltage Rating Vac
250V
Current Rating
2A
No. Of Poles
1
Mounting Type
Panel
Length/height, External
19mm
Voltage Ac
250V
External Width
11mm
External Depth
27.6mm
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Current
rating (A)
0.05
0.08
0.1
0.2
0.3
0.4
0.5
0.6
0.7
0.8
1
1.2
1.5
Authority
VDE (EN 60934), SEV
Demko
CSA, UL
Semko
Kema (EN 60934)
Circuit breakers with -Si51 not approved
Miniaturised single pole thermal circuit breaker with push-to-reset
tease free, trip-free, snap action mechanism (R-type TO CBE to EN
60934). Available in versions for PCB or panel mounting, snap-in or
threadneck, or as an integral type. Approved to CBE standard EN
60934 (IEC 934). For higher current ratings see type 1140.
Motors, transformers, solenoids, printed circuit boards, hand-held
machines and appliances.
The exact part number required can be built up from the table of choices shown
above. Ordering references for optional features should be omitted if not required.
* mounting hardware bulk shipped
Please enquire for packaging quantities
Issue E
Type No.
104
105
106
106-M1
106
Standard current ratings and typical internal resistance values
Description
Typical applications
Approvals
Ordering information
- P30 -
PCB mounting type (-PR), or integral type (-P30/P10)
snap-in panel mounting
threadneck panel mounting with hex and knurled nut *
threadneck mounting for standard fuseholder cutout *
Terminal design
P10
P30
PR
Internal
resistance ( )
285
134
81
22
blade terminals A6.3-0.8
blade terminals A2.8-0.8
solder terminal pins for PCB mounting (type 104 only)
Shunt terminal (optional)
A3
8.7
5.5
3.3
2.45
1.6
1.45
0.9
0.6
0.4
-
Thermal Overcurrent Circuit Breakers 104/105/106-...
same as main terminals (up to I
Auxiliary contacts (optional)
Si51
Voltage ratings
DC 48 V
AC 250 V, DC 28 V
DC 48 V
AC 240 V
AC 250 V, DC 48 V
AC 250 V, DC 48 V
AC 240 V
- 5 A
type 104 only
Current ratings
0.05...10 A
Germany (0 91 87) 10-0 - USA (847) 827-7600 - UK (01296) 420336 - www.e-t-a.com
= ordering example
Current
rating (A)
10
1.8
2
2.5
3
3.5
4
4.5
5
6
7
8
Current ratings
0,05...8 A
0.05...10 A
0.05...10 A
0.05...10 A
0.1...10 A
0,05...8 A
0.05...10 A
N
6 A/3 A max. load)
Internal
resistance ( )
0.28
0.25
0.18
0.11
0.076
0.067
0.051
0.05
0.05
0.05
0.05
0.05
Voltage rating
Current ratings
Auxiliary circuit
Typical life
Ambient temperature
Insulation co-ordination
(IEC 664 and 664 A)
Dielectric strength
(IEC 664 and 664A)
Insulation resistance
Interrupting capacity I
Interrupting capacity
(UL 1077)
Degree of protection
(IEC 529/DIN 40050)
Vibration
Shock
Corrosion
Humidity
Mass
operating area
Technical data
104-...
cn
AC 240 V; DC 48 V
0.05...10 A
0.5 A, AC 240 V, DC 28 V
0.05...5 A: 3,000 operations at 2 x I
6 ...8 A:
10 A
-20...+60 C (T 60)
Rated impulse
withstand voltage
2.5 kV
reinforced insulation in operating area
Test voltage
AC 3,000 V
>100 M
0.05 ... 2 A 6 x I
2.5 ...10 A 5 x I
I
0.05...4.5 A
5 A
6...10 A
0.05...10 A
operating area IP 40
terminal area
10 g (57-500 Hz), 0.76 mm (10-57 Hz),
to IEC 68-2-6, test Fc,
10 frequency cycles/axis
25 g ( 11 ms)
to IEC 68-2-27, test Ea
96 hours at 5 % salt mist,
to IEC 68-2-11, test Ka
240 hours at 95 % RH,
to IEC 68-2-3, test Ca
approx. 10 g
N
105-...
(DC 500 V)
500 operations at 2 x I
50 operations at 2 x I
U
AC 250 V
AC 250 V
AC 250 V
DC 48 V
IP 00
N
N
N
106-...
Pollution
degree
2
1000 A
2000 A
200 A
200 A
N
N
N
25
1

Related parts for 106-P30 2A

106-P30 2A Summary of contents

Page 1

... Thermal Overcurrent Circuit Breakers 104/105/106-... Description Miniaturised single pole thermal circuit breaker with push-to-reset tease free, trip-free, snap action mechanism (R-type TO CBE to EN 60934). Available in versions for PCB or panel mounting, snap-in or threadneck integral type. Approved to CBE standard EN 60934 (IEC 934). For higher current ratings see type 1140. ...

Page 2

... Thermal Overcurrent Circuit Breakers 104/105/106-... 104-PR ø4 1 104-PR 104-PR-A3 0.05...6 A terminal design for correct stand-off distances 1 0 0.2 17 104-PR-(A3-)Si51 ø7 ø4 terminal design for correct stand-off distances 1 0.8 (A3 mounting holes 12.5 104-PR-Si51 104-PR-Si51 104-PR-A3-Si51 7...10 A 9.5 0.05...6 A ø1 ...

Page 3

... Thermal Overcurrent Circuit Breakers 104/105/106-... Dimensions 106-P30 -27UNS-2A tightening torque 0.8 Nm ø4 19 blade terminals DIN 46244-A2.8-0.8 15.7 mounting hole SW14 9 106-P30 106-P30-A3 7...10 A 0.05...6 A 106-M1 tightening torque 0.5 Nm ø18.8 mounting hole panel thickness >0.8 Issue E Germany (0 91 87) 10-0 - USA (847) 827-7600 - UK (01296) 420336 - www.e-t-a.com Installation drawings 104-… ...

Page 4

... Thermal Overcurrent Circuit Breakers 104/105/106-... Internal connection diagrams Types 104 Types 104-...-A3 105 105-...-A3 106 106-...- Typical time/current characteristics at +23 C 10000 1000 100 … times rated current The time/current characteristic curve depends on the ambient temperature prevailing. In order to eliminate nuisance tripping, please multiply the circuit breaker current ratings by the derating factor shown below. See also section 9 – ...

Related keywords