Specifications of NT-ZJCAT1-EV4

Peak Reflow Compatible (260 C)
No
Leaded Process Compatible
No
Rohs Compliant
No
For Use With
NT11 Programmable Terminal
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
6
Note: In order to improve the performance of displays, liquid crystal devices may be ch
Note: In order to improve the performance of displays, liquid crystal devices may be changed
Allowable power
Noise resistance
Vibration resistance
Shock resistance
Ambient operating
temperature
Ambient operating
humidity
Operating
environment
Storage temperature
Enclosure ratings
Weight
Display screen
Indicators
Switch
Display characters
Number of
characters displayed
Display
elements
Screen
attributes
Screen types
Max. number of
registered screens
Screen registration
method
Screen saving
method
NT
NT11
NT11
NT11 General Specifications
Display/Panel Specifications
Display Capacity
without notice.
Item
Item
Item
Character
string
displays
Numeral
Graph
Numeral
settings
history
screen
Menu
screen
24 VDC
Conforms to IEC61000-4-4, 2K (power lines)
10 to 57 Hz with 0.075 mm amplitude and 57 to 150 Hz with
9.8 m/s
147 m/s
0 to +50˚C
35 to 85% RH (with no condensation)
No corrosive gasses.
–20 to +70˚C (with no freezing)
Front panel: Equivalent to IP65, NEMA4
1.0 kg max.
Dot matrix of STN liquid
• Number of dots: 160 x 64
• Effective display area:
• Life expectancy: 50,000 hours
• View angle (left/right direction):
• RUN indicator (Green LED): Lit during operation
• Life expectancy: 1 million operations minimum
Normal characters (8 x 16 dots): Alphanumerics and symbols
Marks (8 x 16 dots): User-defined, 64 max.
Normal-size: 20 horizontally x 4 lines vertically max.
Double width
8 positions per screen
8 positions per screen
4 positions per screen
Order of frequency, 256 screens
Ensures security: screens for which this attribute is set can
only be displayed if the correct password is input.
Four items per screen
Normal screen: Displays screen registered as normal.
250
Transfer screen data created using an IBM PC/AT personal
computer to the PT.
Saved to flash memory: 32 KB (downloading method)
100 x 40 mm
minimum
±20˚
2
2
acceleration for 30 min in each of X, Y, and Z directions
3 times in each of X, Y, and Z directions
Specification
Specification
Specification
Backlight
• LED
• Life expectancy: 50,000 hours
• Automatic turn-off: can be set
minimum
to turn off in 10 minutes or
1 hour, or to remain on.
*
*
Printing function
Maintenance
functions
Terminal*
Support Software
Function key sheet
Connecting cables with the PLC and NTST are the same as those for the NT21.
and a flash ROM that downloads the system program.
Please refer to the next page.
Special Features
NT11 Product Configurations
Outside Dimensions
Panel Plate thickness: 1.6 to 4.8 mm
Recommended panel cutout:
Rear face
Item
Product
Host link direct
connection,
NT link method
80.5
204.2
Printing of display history data
Printing of daily reports (printing format registered by the users)
• Simple communications confirmation.
203
218
+0.5
0
Ten-key type (frame color: beige)
Ten-key type (frame color: black)
CD-ROM (for Windows 95, 98,
Me, XP, NT, 2000)
10 sheets for replacement for beige
10 sheets for replacement for black
Specification
Specification
98.
8
+0.5
0
113
3
NT11-CKF01
NT11-CKF01B
38.2
NT11-SF121-EV1
NT11-SF121B-EV1
NT-ZJCAT1-EV4
Model
98
*
Power consumption
Noise resistance
Vibration resistance
Shock resistance
Ambient operating
temperature
Ambient operating
humidity
Dimensions
Enclosure ratings
Weight
Display
elements
Screen
types
Screen attributes
Number
of
screens
Screen registration
method
Saving screen data
Usage may not be possible in places where the unit would be exposed to oil for long periods.
NT2
NT21
NT21
NT21 General Specifications
Display Capacity
Fixed displays
Character string
displays
Graph displays
Analog meters
Trend graphs
Broken line graphs
Lamps
Image library images
Touch switches
Recipes
Normal screens
Windows
Display history screens
System startup
screen
Programming
Console screen
Max. number of
Screen number
Item
Graphics
Marks
Item
Conforms to IEC61000-4-4. Power supply line: 2 kV
Peak acceleration 15 G,
190 x 110 x 53.5 mm (W x H x D)
(thickness inside panel: 49.0 mm)
Front panel operating section: Equivalent to IP65F, NEMA 4.*
0.6 kg max.
(Graphics:
rectangles, circles,
256 positions per screen, max.
1,024 display elements for overlapping screens
50 positions per screen, capable of displaying signs and percentages
50 positions per screen, capable of displaying signs and percentages
One frame per screen, 50 items per frame
(8 items max. for data logging)
One frame per screen, 256 items per frame,
260 points per item
256 positions per screen
256 positions per screen
256 positions per screen
26 positions per screen
256 positions per screen
One position per screen
Displays screens registered as normal
A maximum of eight screens can be displayed overlapping each other.
Up to three window screens can be displayed.
Order of occurrence (1,024 screens max.), order of frequency (255 times max.)
Displayed when powering ON (or resetting ) the PT,
and when switching to RUN mode.
Emulates PLC Programming Console functions,
capable of being called from RUN mode.
Buzzer, display history, normal background colors,
backlight mode, local windows
3,999
0:
1 to 3999: User registered screens
9000:
9001:
9002:
9020:
9999:
By transferring screen data from the NT Support Tool
to the PT via serial communications
By mounting the Memory Unit and downloading
(automatic/manual transfer) data to the PT
Flash memory (PT internal image memory)
˚
±15%
˚
No display
(normal, overlapping, windows)
System startup screen
Display history screens, order of occurrence
Display history screens, order of frequency
Programming Console screen
Return to previous screen designation
Specification
2
acceleration,
Specification
With overlapping screens,
the total is
524,280 per screen
Total of 256 positions
for both numerical and
thumbwheel settings
˚C)
*
53.5
Panel thickness: 1.6 to 4.8 mm
178.5
110
Display
panel
Backlight
(white cold cathode
tube)
Touch
panel
NT Support Tool
PLC
SBC/personal computer
Bar Code Reader
Connection via RS-422A/485 is possible using the NS-AL002 RS-232C/422A Adapter (connector),
which can be connected only to serial port B. (RS-485 connections must use 1:N NT Links.)
NT21
Programmable
Terminal
Support Tool l
Cables
Options
Display Specifications
Panel Specifications
External Interface Specifications
NT21 Standard Models
Dimensions
Product
+0.5
Host Link
1:1 NT Link
1:N NT Links
NT Link, PT Programming Console function
/
/ / x 100.5
Display device
Number of dots (resolution)
Effective display area
Viewing angle
Display color
Service life
Automatic turn-OFF
Number of switches
Input
Life expectancy
Communications method
Monochrome STN
Windows 95, 98, Me, NT, or 2000
For screen transfer
For
PLC
connection
Reflection Protective Sheets
Chemical-resistive Cover
Battery
Memory Unit
RS-232C/422A Adapter
Connector Kit
Item
Item
/
/ /
0
178
142
190
Service life
Replacement
mm (W x H)
15.5
PT: 9-pin
PLC: 9-pin
PT: 9-pin
PLC: 25-pin
PT: 9-pin
PLC: Mini-peripheral
Memory Links
Specification
Monochrome STN LCD
260 dots horizontally x 140 dots vertically
117 mm horizontally x 63 mm vertically
Black & white (with blue mode)
50,000 hours min. (until contrast reduced to 50%)
Can be set to turn OFF in 1 to 255 min or to
remain ON with screen saver
50,000 hours min. (at room temperature,
until brightness is reduced to 50%)
Non-replaceable
Display area only (5 sheets)
Silicon cover
For alarm lists/histories
For screen and system
data transfer
91 (13 horizontally x 7 vertically)
Pressure-sensitive
1 N max.
1 million operations min.
4.5
CD-ROM
Frame color: beige
Cable length: 2 m
Cable length: 2 m
Cable length: 5 m
Cable length: 5 m
Supported
Supported
Supported
Supported
Supported
Supported
Supported
Serial port A
Specification
39 min.
Specification
19.5
˚
100
122
NT21-ST121-E
NT-ZJCAT1-EV4
XW2Z-S002
XW2Z-200T
XW2Z-200S
XW2Z-500S
XW2Z-500T-2
NT20M-KBA04
NT20S-KBA01
C500-BAT08
NT-MF161
NS-AL002
XM2S-0911-S003
Not supported
Supported
Supported
Supported
Supported
Supported
Not supported
Model number
52.5
Serial port B
˚
28

Related parts for NT-ZJCAT1-EV4