D4C-1202 Omron, D4C-1202 Datasheet - Page 9

no-image

D4C-1202

Manufacturer Part Number
D4C-1202
Description
SMALL LIMIT SWITCH
Manufacturer
Omron
Series
D4Cr
Datasheets

Specifications of D4C-1202

Rohs Compliant
YES
Circuit
SPDT
Switch Function
On-Mom
Contact Rating @ Voltage
5A @ 250VAC
Actuator Type
Roller Plunger
Mounting Type
Chassis Mount
Termination Style
Cable Leads
Operating Force
1177gf
Actuator Style
Roller Plunger
Operating Force Max
11.77N
Contact Voltage Ac Max
250V
Contact Voltage Dc Max
30V
Contact Current Ac Max
5A
Contact Current Dc Max
4A
Switch Terminals
Cable
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
D4C1202
Note 1. The above figures are initial values.
168
Degree of protection
Durability (see note 2)
Operating speed
Operating frequency
Rated frequency
Insulation resistance
Contact resistance (initial)
Dielectric strength
Rated insulation voltage (U
Switching overvoltage
Pollution degree
(operating environment)
Short-circuit protective device (SCPD) 10 A fuse type gI or gG (IEC269)
Conditional short-circuit current
Conventional enclosed thermal current
(I
Protection against electric shock
Vibration resistance
Shock resistance
Ambient temperature (see note)
Ambient humidity
Weight (D4C-1202)
the
Characteristics
)
2. The values are calculated at an operating temperature of 5 C to 35 C, and an operating humidity of 40% to 70%. Contact your OMRON
3. Prewired Connector Models: 1,000,000 operations min. (DC specifications, switching current: 0.1 A)
4. Outdoor specifications: 500,000 operations min.
5. Excluding Plastic Rods.
sales representative for more detailed information on other operating environments.
Enclosed Switch
i
)
D4C
IP67
Mechanical: 10,000,000 operations min. (see note 4)
Electrical:
0.1 mm to 0.5 m/s (in case of plunger)
1 mm to 1 m/s (in case of roller lever)
Mechanical: 120 operations/min
Electrical:
50/60 Hz
100 M
250 m
300 m
400 m
1,000 VAC, 50/60 Hz for 1 min between terminals of the same polarity
1,500 VAC, 50/60 Hz for 1 min between current-carrying metal part and ground, and between each
terminal and non-current-carrying metal part, Uimp: 2.5 kV (EN60947-5-1)
300 V (EN60947-5-1)
1,000 VAC, 300 VDC max. (EN60947-5-1)
3 (IEC60947-5-1)
100 A (EN60947-5-1)
5 A, 4 A, 0.5 A (EN60947-5-1)
Class I (with grounding wire)
Malfunction: 10 to 55 Hz, 1.5-mm double amplitude (see note 5)
Destruction: Approx. 1,000 m/s
Malfunction: Approx. 500 m/s
Operating: –10 C to 70 C (with no icing)
Operating: 35% to 95%
With 3-m VCTF cable: 360 g; With 5-m VCTF cable: 540 g
min. (at 500 VDC)
max. (initial value with 2-m VCTF cable)
max. (initial value with 3-m VCTF cable)
max. (initial value with 5-m VCTF cable)
200,000 operations min. (5A at 250 VAC, resistive load) (see note 3)
30 operations/min
2
min. (see note 5)
2
min.

Related parts for D4C-1202