FH1484 OSRAM, FH1484 Datasheet - Page 6

LAMP, T5, 550MM, CW, 14W

FH1484

Manufacturer Part Number
FH1484
Description
LAMP, T5, 550MM, CW, 14W
Manufacturer
OSRAM
Datasheet

Specifications of FH1484

Supply Voltage
230V
Base Type
T5
Power Rating
14W
Luminous Flux
1350lm
Length
550mm
Colour Temperature Typ
4000K
Svhc
No SVHC (15-Dec-2010)
Colour
Cool White
External Diameter
16mm
Lamp Base Type
T5
Average Bulb Life
20000h
Bulb Diameter
16mm
Technical Data
QUICKTRONIC
lamps (T5, 16 mm dia.)
Fully electronic hum-free
control gear for OSRAM FH
lamps
Optimised warm start, high
resistance to switching transients
Cut-off priciple for low electrode
loading
Extremely slim ECG cross-section:
30 x 29 mm
Tested in accordance with general
and safety-related requirements for
ECGs to EN 60928 for ac supply
and EN 60924 for dc supply;
tested in accordance with ECG
operating guidelines to EN 60929
®
THERE IS LIGHT. AND THERE IS OSRAM.
for FH fluorescent
®
Lamp
Wattage
Rated luminous flux (25° C)
Max. luminous flux (35° C)
Colour rendering
Light colour
Lamp length l
Lamp base
ECG reference 1-lamp
Mains voltage
Mains frequency
System wattage
Length l
Distance between holes a
Width b
Height h
Ambient temperature range
ECG reference 2-lamp
Mains voltage
Mains frequency
System wattage
Length l
Distance between holes a
Width b
Height h
Ambient temperature range
1
) Lighting plans and luminaire measurements should be based on the rated luminous flux.
(T5)
0
Active harmonic filter to
protect against mains pollution
to EN 61000-3-2
Radio interference suppressed to
EN 55015 and DIN VDE 0875
Immune to external noise to
EN 61547
Protective shutdown in the event of
an overvoltage
Integrated safety shutdown of
defective lamps
– if lamp electrodes cease to emit
– if there is an unusual temperature
– if the lamp output increases
Approval marks:
0 i m .
rise at the lamp electrodes
1
)
FH
14 W
1270 lm
1350 lm
R
550 mm
G5
QT-FH 1x14/
230–240
230/240 V
0/50–60 Hz
16 W
280 mm
273 mm
–15° to + 50°C
QT-FH 2x14/
230–240
230/240 V
0/50–60 Hz
30,5 W
360 mm
350 mm
–15° to +50°C
30 mm
30 mm
30 mm
30 mm
a
85
®
14 W
a
l
830 = 3000 K, 840 = 4000 K, 860 = 6000 K
FH
21 W
1970 lm
2100 lm
R
850 mm
G5
QT-FH 1x21/
230–240
230/240 V
0/50–60 Hz
23.5 W
280 mm
273 mm
–15° to +50°C
QT-FH 2x21/
230–240
230/240 V
0/50–60 Hz
46 W
360 mm
350 mm
–15° to +50°C
30 mm
30 mm
30 mm
30 mm
a
85
®
21 W
l
Failure rate: per 1000 hours 1–2‰
at a measuring point temperature
of 70°C
ECG life: 10% failure after
50,000 hours at a measuring point
temperature of 70°C
Can be used in emergency
lighting to VDE 0108 (EN 60924
and EN 60928)
– dc voltage range: 176 V to 254 V
– ac voltage range: 198 V to 254 V
For luminaires with l and ll
or q and qq symbols to
EN 60598/DIN VDE 0710
FH
28 W
R
2720 lm
2900 lm
1150 mm
G5
QT-FH 1x28/
230–240
230/240 V
0/50–60 Hz
30.5 W
360 mm
350 mm
–15° to +50°C
QT-FH 2x28/
230–240
230/240 V
0/50–60 Hz
62 W
360 mm
350 mm
–15° to +50°C
30 mm
30 mm
30 mm
30 mm
a
OSRAM
85
®
28 W
h
b
Dimensions in mm
FH
35 W
3430 lm
3650 lm
R
1450 mm
G5
QT-FH 1x35/
230–240
230/240 V
0/50–60 Hz
38.5 W
360 mm
350 mm
–15° to +50°C
QT-FH 2x35/
230–240
230/240 V
0/50–60 Hz
76 W
360 mm
350 mm
–15° to +50°C
30 mm
30 mm
30 mm
30 mm
a
ø16
85
®
35 W

Related parts for FH1484