M265 OSRAM, M265 Datasheet - Page 4

LAMP, DICHROIC, SPOT, 35W

M265

Manufacturer Part Number
M265
Description
LAMP, DICHROIC, SPOT, 35W
Manufacturer
OSRAM
Datasheet

Specifications of M265

Supply Voltage
12V
Base Type
GU4
Power Rating
35W
Reflector Dia
35mm
Colour Temperature Typ
3100K
Svhc
No SVHC (15-Dec-2010)
Angle
10°
Beam Type
Spot
External Length / Height
37mm
Luminous
RoHS Compliant
Lamp Base Type
GU4
Rohs Compliant
Yes
Average Bulb Life
2000h
Length
37mm
Temperature behaviour:
Measurement point (see
„Geometry“)
Burning position
Max. temperatures permit-
ted acc. to IEC
Operating temperatures
measured free burning
Operating conditions:
Burning positions
Dimmability
Areas of application
Near field
Safety informations:
Environment sensitifity:
Validity:
HAL M-M, Edition November 05
Subject to alteration
Measurement conditions:
Measurement in the most unfavourable burning position for the pinch.
The burning position only has a minimum influence on the temperature of the top part of the
reflector and on the joint
Surrounding temperature: 25° (acc. DIN 5032)
Voltage: 12,0V
Lamp holder: Bender & Wirth 994
Operating temperatures for free burning use are not obliging and are useful for orientation.
Any
100%
For outdoor applications and operation in damp locations special approved fixtures are required.
The lamps are not qualified for applications, whereat defined near field features are necessary.
According to IEC 60598-1/DIN VDE 0711 "minimum security distance" the max. temperature
permitted is 90°C. This max. temperature has to be ensured by the minimum distance.This
distance has to be determined by appropriate measurements and specified on the luminaire.
When replacing conventional cold light reflector lamps without cover pane by Decostar 35S,
temperature inside the lighting will rise. For this reason the suitability of the use of a luminaire
with a lamp with cover pane must be secured (see use instructions of control gear)
DECOSTAR 35S can be disposed as household waste.
In the first few hours of operation what is left of humidity can be expelled from the glue
This has no influence to the lampe use.
These technical information sheets (TI-sheets) are updated in irregular intervals. The user is
responsible to ensure that the information they have is up to date and still valid. Once a new TI
sheet has been issued, former editions are to be seen as invalid and disposed of.
10W
20W
35W
350°C
140°C
180°C
290°C
Pinch
4/4
P1
10W, 20W:220°C
35W: 250°C
110°C
75°C
85°C
Pin
P2
Halogen dichroic reflector lamp ∅ 35 mm
Base up
DECOSTAR 35S
Reflector
100°C
120°C
160°C
P3
-
Technical Information
220°C
110°C
130°C
180°C
Joint
P4

Related parts for M265