Specifications of ACPL-P302-500E

Voltage - Isolation
3750Vrms
Number Of Channels
1, Unidirectional
Current - Output / Channel
400mA
Propagation Delay High - Low @ If
300ns @ 7mA
Current - Dc Forward (if)
12mA
Input Type
DC
Output Type
Push-Pull, Totem-Pole
Mounting Type
Surface Mount
Package / Case
SO-6
Number Of Elements
1
Forward Voltage
1.8V
Forward Current
25mA
Isolation Voltage
3750Vrms
Operating Temp Range
-40C to 100C
Power Dissipation
250mW
Propagation Delay Time
700ns
Pin Count
6
Mounting
Surface Mount
Reverse Breakdown Voltage
5V
Operating Temperature Classification
Industrial
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Table 2. Insulation and Safety Related Specifications
Table 3. Absolute Maximum Ratings
Table 4.Recommended Operating Conditions
5
Parameter
Minimum External Air Gap
(External Clearance)
Minimum External Tracking
(External Creepage)
Minimum Internal Plastic Gap
(Internal Clearance)
Minimum Internal Tracking
(Internal Creepage)
Tracking Resistance
(Comparative Tracking Index)
Isolation Group
Parameter
Storage Temperature
Operating Temperature
Average Input Current
Peak Transient Input Current
(<1 μs pulse width, 300pps)
Reverse Input Voltage
“High” Peak Output Current
“Low” Peak Output Current
Supply Voltage
Output Voltage
Output Power Dissipation
Input Power Dissipation
Lead Solder Temperature
Solder Reflow Temperature Profile
Parameter
Power Supply
Input Current (ON)
Input Voltage (OFF)
Operating Temperature
Symbol
L(101)
L(102)
CTI
ACPL-P302
7.0
8.0
0.08
NA
>175
IIIa
Symbol
T
T
I
I
V
I
I
V
V
P
P
260°C for 10 sec., 1.6 mm below seating plane
See Package Outline Drawings section
Symbol
V
I
V
T
F(AVG)
F(TRAN)
OH(PEAK)
OL(PEAK)
F(ON)
A
S
A
R
CC
O(PEAK)
O
I
CC
F(OFF)
- V
- V
EE
EE
ACPL-W302
8.0
8.0
0.08
NA
>175
IIIa
Min.
-55
-40
-0.5
-0.5
Min.
10
7
- 3.6
- 40
Units
mm
mm
mm
mm
V
Max.
125
100
25
1.0
5
0.4
0.4
35
V
250
45
Max.
30
12
0.8
100
Conditions
Measured from input terminals to output
terminals, shortest distance through air.
Measured from input terminals to output
terminals, shortest distance path along body.
Through insulation distance conductor to
conductor, usually the straight line distance
thickness between the emitter and detector.
Measured from input terminals to output
terminals, along internal cavity.
DIN IEC 112/VDE 0303 Part 1
Material Group (DIN VDE 0110, 1/89, Table 1)
CC
Units
°C
°C
mA
A
V
A
A
V
V
mW
mW
Units
V
mA
V
°C
Note
1
2
2
3
4
Note