HCNW2611 Avago Technologies US Inc., HCNW2611 Datasheet - Page 9

Optocoupler

HCNW2611

Manufacturer Part Number
HCNW2611
Description
Optocoupler
Manufacturer
Avago Technologies US Inc.
Datasheet

Specifications of HCNW2611

No. Of Channels
1
Isolation Voltage
5kV
Optocoupler Output Type
Logic Gate
Input Current
15mA
Output Voltage
7V
Opto Case Style
DIP
No. Of Pins
8
Propagation Delay Low-high
100ns
Common Mode Voltage Vcm
1000V
Voltage - Isolation
5000Vrms
Number Of Channels
1, Unidirectional
Current - Output / Channel
50mA
Data Rate
10MBd
Propagation Delay High - Low @ If
50ns @ 7.5mA
Current - Dc Forward (if)
20mA
Input Type
DC
Output Type
Open Collector
Mounting Type
Through Hole
Package / Case
8-DIP (0.400", 10.16mm)
Number Of Elements
1
Baud Rate
10Mbps
Forward Voltage
1.85V
Forward Current
20mA
Output Current
50mA
Package Type
PDIP W
Operating Temp Range
-40C to 85C
Power Dissipation
85mW
Propagation Delay Time
75ns
Pin Count
8
Mounting
Through Hole
Reverse Breakdown Voltage
3V
Operating Temperature Classification
Industrial
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant, Contains lead / RoHS non-compliant
Other names
516-1082-5

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
HCNW2611
Manufacturer:
AVAGO
Quantity:
8 892
Part Number:
HCNW2611
Manufacturer:
AGILENT
Quantity:
20 000
Company:
Part Number:
HCNW2611
Quantity:
16
Part Number:
HCNW2611#300
Manufacturer:
AVAGO
Quantity:
8 892
Part Number:
HCNW2611#500
Manufacturer:
AVAGO
Quantity:
8 892
Part Number:
HCNW2611-000E
Manufacturer:
AVAGO
Quantity:
30 000
Part Number:
HCNW2611-000E
Manufacturer:
AVAGO/安华高
Quantity:
20 000
Part Number:
HCNW2611-300E
Manufacturer:
AVAGO
Quantity:
30 000
Part Number:
HCNW2611-300E
Manufacturer:
AVAGO/安华高
Quantity:
20 000
Part Number:
HCNW2611-500E
Manufacturer:
AVAGO/安华高
Quantity:
20 000
IEC/EN/DIN EN 60747-5-2 Insulation Related Characteristics
(HCPL-06xx Option 060 Only)
*Refer to the front of the optocoupler section of the current catalog, under Product Safety Regulations section, IEC/EN/DIN EN 60747-5-2, for a
detailed description.
Note: Isolation characteristics are guaranteed only within the safety maximum ratings which must be ensured by protective circuits in applica-
tion.
9
Description
Installation classification per DIN VDE 0110/1.89, Table 1
Climatic Classification
Pollution Degree (DIN VDE 0110/1.89)
Maximum Working Insulation Voltage
Input to Output Test Voltage, Method b*
Input to Output Test Voltage, Method a*
Highest Allowable Overvoltage
(Transient Overvoltage, t
Safety Limiting Values
Insulation Resistance at T
V
V
for rated mains voltage ≤ 150 V rms
for rated mains voltage ≤ 300 V rms
for rated mains voltage ≤ 600 V rms
Partial Discharge < 5 pC
t
(Maximum values allowed in the event of a failure)
m
IORM
IORM
Case Temperature
Input Current**
Output Power**
= 60 sec, Partial Discharge < 5 pC
x 1.875 = V
x 1.5 = V
PR
, Type and Sample Test,
PR
, 100% Production Test with t
ini
S
, V
= 10 sec)
IO
= 500 V
m
= 1 sec,
P
Symbol
I
S,OUTPUT
V
V
S,INPUT
V
V
IORM
IOTM
T
R
PR
PR
S
S
Characteristic
55/85/21
1063
6000
≥10
567
851
150
150
600
I-IV
I-III
I-III
2
9
Units
V
V
V
V
mW
mA
°C
:
peak
peak
peak
peak