102PMBS-G1 EDWARDS SIGNALING PRODUCTS, 102PMBS-G1 Datasheet - Page 2

no-image

102PMBS-G1

Manufacturer Part Number
102PMBS-G1
Description
LAMP, STACKABLE, INDICATOR
Manufacturer
EDWARDS SIGNALING PRODUCTS
Datasheet

Specifications of 102PMBS-G1

Bulb Size
76mm
Supply Voltage
24V
Current Rating
1.75A
Ip/nema Rating
IP65 / NEMA 3R, 4X
Leaded Process Compatible
No
Peak Reflow Compatible (260 C)
No
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
4. Assemble the stackable beacon lighting system (Figure 3).
P/N 3100669 ISSUE 1
To prevent leakage, ensure the magnifier ring on
the lens cover and the magnifier ring on the lens
module are aligned (Figure 3).
TO NEUTRAL
ON CAT. 102TBS
TERMINAL BLOCK
d.
a.
b.
c.
Figure 2. Wiring Cat. No. 102SIG*T
Figure 1. Wiring Cat. No. 102TBS
Insert the appropriate light source into board grooves at
(1) To sound tone module independently, connect to
(2) To sound tone module with a particular light, connect
Pull the captive key in the lens module into the "out"
position.
Place the first lens module on top of the base.
Push in the captive key to secure the lens module.
separate hot lead.
horn hot terminal to selected light terminal on Cat.
102TBS terminal block.
N
H
WARNING
SEPARATE HOT LEAD OR
CONNECTED TO APPROPRIATE
LIGHT MODULE TERMINAL ON
CAT. 102TBS TERMINAL BLOCK
Figure 3. Assembling the Stackable Status Indicator (Cat. No. 102TBS shown for
(381mm)
15"
(13mm)
(92mm)
(92mm)
3 5/8"
1/2"
3 5/8"
NOTE: When using LED light sources, ensure that the color of
5. Apply power to the unit and verify proper operation.
To prevent electrical shock, disconnect power to all
modules. Wait 5 minutes for stored energy in strobe
modules to dissipate before working on unit.
e.
f.
g. Once the last module has been assembled, place the cap
(76mm)
bottom of lens module, ensuring that the four prongs on
the PC board are aligned with the plug located in the
back of the lens assembly.
the LED light source and the lens assembly match.
Place the lens assembly cover on the front of the lens
module and secure using two captive screws.
Repeat steps a through e for any remaining modules (up
to 5).
on top and secure the cap with the captive screw.
3"
illustration purposes only)
WARNING
Magnifier
Ring
Board
Groove
Cap (supplied with base)
Captive Key
Light Source
Assembly
Signal Base
(Cat. No. 10STBS shown)
(2) Captive
Screws
Lens Module
Cover