BMA150-0330SB0003 BOSCH, BMA150-0330SB0003 Datasheet - Page 19

Daughter Board

BMA150-0330SB0003

Manufacturer Part Number
BMA150-0330SB0003
Description
Daughter Board
Manufacturer
BOSCH
Datasheet

Specifications of BMA150-0330SB0003

Silicon Manufacturer
Bosch
Application Sub Type
Accelerometer - Three-Axis
Kit Application Type
Sensing - Motion / Vibration / Shock
Silicon Core Number
BMA150
Kit Contents
Board
3.2.10 New_data_int
If this bit (address 15h, bit 5) is set to 1, an interrupt will be generated when all three axes
acceleration values are new, i.e. BMA150 updated all acceleration values after latest serial
read-out. Interrupt generated from new data detection is a latched one; microcontroller has to
write reset_INT at 1 after interrupt has been detected high (section 3.3.1). This interrupt is also
reset by any acceleration byte read procedure (read access to address 02h to 07h).
New data interrupt always occurs at the end of the Z-axis value update in the output register
(3kHz rate). Following figure shows two examples of X-axis read out and the corresponding
interrupt generation.
Figure 3: Explanation of new data interrupt.
left side - read out command of x-axis prior to next x-axis conversion
right side - read out of x-axis send after x-axis conversion
Please refer to chapter 8.1 for more details.
Note: When using the I
330µs (depending on I
data read out sequence may lead to the situation that the new_data_int may not be cleared right
in time. This must be considered and taken care of properly.
Rev. 1.5
© Bosch Sensortec GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such
as copying and passing on to third parties. BOSCH and the symbol are registered trademarks of Robert Bosch GmbH, Germany.
Note: Specifications within this document are subject to change without notice.
X-axis value read out
T
conversion
→ new data interrupt after completion of current conversion cycle after z-axis
→ new data interrupt at the end of next period when x axis has been updated
New data interrupt
X
Y
Z
T
X-axis value read out
2
2
C interface for data transfer, the data read out phase can be longer than
C clock frequency and the amount of data transmitted). Starting a new
X
Y
Triaxial, digital acceleration sensor
Z
T
X
X-axis value read out
New data interrupt
Y
Data sheet
BMA150
Page 19
Z
T
New data interrupt
X
Y
Z
T
X-axis value read out
X
Y
Z
T
X
New data interrupt
Y
Bosch Sensortec
Z
30 May 2008

Related parts for BMA150-0330SB0003