09 69 181 7420 HARTING, 09 69 181 7420 Datasheet

CONTACT, FEMALE, 10 AMP

09 69 181 7420

Manufacturer Part Number
09 69 181 7420
Description
CONTACT, FEMALE, 10 AMP
Manufacturer
HARTING
Series
D-Sub-Mr
Datasheet

Specifications of 09 69 181 7420

Connector Type
Contact, Solder
Contact Plating
Gold
Contact Material
Copper Alloy
Gender
Socket
Svhc
No SVHC (15-Dec-2010)
Contact Termination
Solder
Contact Gender
Socket
Contact Type
High Current
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
For Use With
D Sub Connectors
Tooling see chapter 31
Hoods see chapter 07
D-Sub – M
D-Sub – Mixed subminiature D connectors
D-Sub mixed connector system – general information . . . . . . . . . . . . . . . . . . .
Contact arrangements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Connectors for pcb applications – general information . . . . . . . . . . . . . . . . . . .
Connectors for cable applications – general information . . . . . . . . . . . . . . . . . .
Technical characteristics for shells . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Mixed shells
with pre-mounted signal solder cup contacts . . . . . . .
Shells without signal contacts for cable applications . .
Coded shells without signal contacts for cable applications . . . . . . . . . . . . . . . .
Mixed shells for signal crimp contacts . . . . . . . . . . . . .
Technical characteristics for special contacts . . . . . . . . . . . . . . . . . . . . . . . . . .
Straight signal crimp contacts for cable applications . . . . .
High voltage contacts for cable applications . . . . . . . . . . .
Straight power contacts for cable applications . . . . . . . . .
Coaxial contacts for cable applications . . . . . . . . . . . . . . .
Pneumatic contacts for cable applications . . . . . . . . . . . . .
Pcb hole patterns . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Board drillings for connectors with straight pcb contacts . . . . . . . . . . . . . . . . . .
Board drillings for connectors with right angled pcb contacts . . . . . . . . . . . . . .
Customer request form for pcb connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Customer request form for cable connectors . . . . . . . . . . . . . . . . . . . . . . . . . . .
Directory chapter 04
04.02
04.03
04.04
04.05
04.06
04.07
04.14
04.15
04.17
04.21
04.22
04.23
04.24
04.26
04.29
04.30
04.30
04.35
04.40
04.42
Page
04 .
01

Related parts for 09 69 181 7420

09 69 181 7420 Summary of contents

Page 1

D-Sub – M D-Sub – Mixed subminiature D connectors D-Sub mixed connector system – general information . . . . . . . . . . . . . . . . . . . Contact arrangements . . . ...

Page 2

... D-Sub mixed connector system HARTINGs’ mixed D-Sub range brings the advantage of an industry standard I/O inter- connect product with the possibility to customise for any application. The range is designed around the standard D-Sub shell sizes with the possibility to have a blend of contacts such as signals with coaxial, power, high voltage or pneumatic contacts ...

Page 3

... Example: 13W3 stands for 13 contacts in total with 10 signal contacts and 3 special contacts. Shell size 2W2C 1 5W1 1 3W3 2 3W3C 2 7W2 2 11W1 2 5W5 3 9W4 3 13W3 3 17W2 3 21W1 3 Shell size 7W7 4 8W8 4 13W6 4 21WA4 4 25W3 4 27W2 4 24W7 5 36W4 5 Note: for any other layout please consult your HARTING representative ...

Page 4

... D-Sub Connectors for pcb applications – general information The range of pcb connectors available at HARTING is summarised in the table under. For each of the basic connector versions, the available contact styles are documented with termination process, pitch, plating, rating for power contacts and impedance for coaxial contact etc..., as well as the accessory configuration. ...

Page 5

D-Sub Connectors for cable applications – general information Two termination processes are available: crimp or solder Shell Crimp termination Signal contacts For wire gauge: AWG 20-24 or 26-28 ● Plating: 0.76 µm or 0.2 µm Au over Ni ● Crimp ...

Page 6

D-Sub mixed connectors Number of contacts Approvals Working current Temperature range The higher temperature limit includes the ambient and heating effect of the contacts under load Materials Mouldings Metal shell Technical characteristics for special contacts see page ...

Page 7

D-Sub DIN 41 652 T1 Number of contacts 7--27 Mixed shells with pre-mounted signal solder cup contacts Identification Male connectors Female connectors 1) Explanations see page 04.03 S4: ≥ 0.76 µ No. of contacts 1) male connectors Performance ...

Page 8

D-Sub DIN 41 652 T1 Number of contacts 9--25 Mixed shells with pre-mounted signal solder cup contacts Identification Male connectors Explanations see page 04.03 S4: ≥ 0.76 µ Board drillings see pages 04.30 ff ...

Page 9

D-Sub DIN 41 652 T1 Number of contacts 9--25 Mixed shells with pre-mounted signal solder cup contacts Identification Female connectors Board drillings see pages 04.30 ff Drawing 13W3, 25W3 Dimensions in mm 9W4 Solder cup termination for AWG 20 (0.5 ...

Page 10

D-Sub DIN 41 652 T1 Number of contacts 5--21 Mixed shells with pre-mounted signal solder cup contacts Identification Male connectors Female connectors Explanations see page 04.03 S4: ≥ 0.76 µ Board drillings see pages ...

Page 11

D-Sub DIN 41 652 T1 Number of contacts 13 Mixed shells with pre-mounted signal solder cup contacts Identification Male connectors Female connectors 1) Explanations see page 04.03 S4: ≥ 0.76 µ Board drillings see pages 04.30 ff No. ...

Page 12

D-Sub DIN 41 652 T1 Number of contacts 24 Mixed shells with pre-mounted signal solder cup contacts Identification Male connectors Female connectors Explanations see page 04.03 S4: ≥ 0.76 µ Board drillings see pages ...

Page 13

D-Sub DIN 41 652 T1 Number of contacts 36 Mixed shells with pre-mounted signal solder cup contacts Identification Male connectors Female connectors 1) Explanations see page 04.03 S4: ≥ 0.76 µ Board drillings see pages 04.30 ff No. ...

Page 14

D-Sub DIN 41 652 T1 Number of contacts 3--8 Shells without signal contacts for cable applications Identification Male connectors Female connectors Explanations see page 04.03 Board drillings see pages 04.30 ff Order special contacts separately. See ...

Page 15

D-Sub DIN 41 652 T1 Number of contacts 2 Coded shells without signal contacts for cable applications Identification Male connectors Female connectors 1) Explanations see page 04.03 Board drillings see pages 04.30 ff Order special contacts separately. See pages 04.21 ...

Page 16

D-Sub DIN 41 652 T1 Number of contacts 3 Coded shells without signal contacts for cable applications Identification Male connectors Female connectors Explanations see page 04.03 Board drillings see pages 04.30 ff Order special contacts separately. ...

Page 17

D-Sub DIN 41 652 T1 Number of contacts 7--21 Mixed shells for signal crimp contacts Identification Male connectors Female connectors 1) Explanations see page 04.03 Board drillings see pages 04.30 ff Order special contacts separately. See pages 04.21 ff No. ...

Page 18

D-Sub DIN 41 652 T1 Number of contacts 13 Mixed shells for signal crimp contacts Identification Male connectors Female connectors Explanations see page 04.03 Board drillings see pages 04.30 ff Order special contacts separately. See pages ...

Page 19

D-Sub DIN 41 652 T1 Number of contacts 11--21 Mixed shells for signal crimp contacts Identification Male connectors Female connectors 1) Explanations see page 04.03 Order special contacts separately. See pages 04.21 ff Board drillings see pages 04.30 ff No. ...

Page 20

D-Sub DIN 41 652 T1 Number of contacts 36 Mixed shells for signal crimp contacts Identification Male connectors Female connectors Explanations see page 04.03 Board drillings see pages 04.30 ff Order special contacts separately. See pages ...

Page 21

D-Sub mixed connectors Signal contacts see page 04.22 Working current 5 A Test voltage U – r.m.s. Operating voltage – Contact resistance – Impedance – Frequency range – Temperature range – Mating cycles ≥ 500 high performance level ≥ 200 ...

Page 22

D-Sub DIN 41 652 T1 Straight signal crimp contacts for cable applications Identification Male contact Female contact Male contact Female contact S4: ≥ 0.76 µ Tooling see chapter 31 Wire gauge (mm²) Performance level 3 ...

Page 23

D-Sub DIN 41 652 T1 High voltage contacts for cable applications Identification Straight versions Right angled versions Straight versions Right angled versions 1) for mating and terminating side Wire gauge (mm²) Male contacts Plating: 1.3 µm Au 0.25 - 0.56 ...

Page 24

... S4: ≥ 0.76 µ Tooling see chapter 31 2) Dimensions see page 04.25 Rating (A) þ Performance level 281 7420 281 7421 281 7422 281 7423 181 7420 181 7421 181 7422 181 7423 282 7420 282 7421 282 7422 282 7423 182 7420 182 7421 ...

Page 25

D-Sub DIN 41 652 T1 Straight power contacts for cable applications Identification Drawing Male contacts Female contacts solder stripping dimensions Rating (A) ø a -0.1 ø b ±0.05 10 1.8 2.54 20 2.7 3.63 30 3.5 4.40 40 4.8 5.50 ...

Page 26

D-Sub DIN 41 652 T1 Coaxial contacts for cable applications Identification Solder / crimp contact for cables RG 174 U, 188 AU, 316 U for cables RG 178 BU, 196 AU, 404 U for cables RG 58 CU, 141 AU ...

Page 27

D-Sub DIN 41 652 T1 Coaxial contacts for cable applications Identification Male contacts Part No. ø a ø b ø c ø 281 x140 0.85 1.9 2.6 3 281 x141 0.85 1.2 1.7 2.3 09 ...

Page 28

D-Sub DIN 41 652 T1 Coaxial contacts for cable applications Identification Female contacts Part No. ø a ø b ø 181 x140 0.85 1.9 2 181 x141 0.85 1.2 1 181 x230 0.50 ...

Page 29

D-Sub DIN 41 652 T1 Pneumatic contacts for cable applications Identification Male contacts Female contacts Male contacts Female contacts Inner diameter air tube (mm Part No x87 0061 09 69 ...

Page 30

D-Sub DIN 41 652 T1 Board drillings for connectors with straight pcb contacts Pcb hole patterns In the next pages, the pcb hole pattern is given for the power and the coaxial contact per connector layout. In the case of ...

Page 31

D-Sub DIN 41 652 T1 Board drillings for connectors with straight pcb contacts Identification Drawing Male connector* 7W7 8W8 9W4 11W1 * When using a female connector with straight pcb contacts the board drilling pattern must be mirrored in the ...

Page 32

D-Sub DIN 41 652 T1 Board drillings for connectors with straight pcb contacts Identification Drawing Male connector* 13W3 13W6 17W2 When using a female connector with straight pcb contacts the board drilling pattern must be mirrored ...

Page 33

D-Sub DIN 41 652 T1 Board drillings for connectors with straight pcb contacts Identification Drawing Male connector* 21W1 21WA4 24W7 * When using a female connector with straight pcb contacts the board drilling pattern must be mirrored in the Y ...

Page 34

D-Sub DIN 41 652 T1 Board drillings for connectors with straight pcb contacts Identification Drawing Male connector* 25W3 27W2 36W4 When using a female connector with straight pcb contacts the board drilling pattern must be mirrored ...

Page 35

D-Sub DIN 41 652 T1 Board drillings for connectors with right angled pcb contacts Identification Drawing Male connector* 2W2C 3W3 / 3W3C 5W1 5W5 7W2 * When using a female connector with right angled pcb contacts the board drilling pattern ...

Page 36

D-Sub DIN 41 652 T1 Board drillings for connectors with right angled pcb contacts Identification Drawing Male connector* 7W7 8W8 9W4 11W1 When using a female connector with right angled pcb contacts the board drilling pattern ...

Page 37

D-Sub DIN 41 652 T1 Board drillings for connectors with right angled pcb contacts Identification Drawing Male connector* 13W3 13W6 17W2 * When using a female connector with right angled pcb contacts the board drilling pattern must be mirrored in ...

Page 38

D-Sub DIN 41 652 T1 Board drillings for connectors with right angled pcb contacts Identification Drawing Male connector* 21W1 21WA4 24W7 When using a female connector with right angled pcb contacts the board drilling pattern must ...

Page 39

D-Sub DIN 41 652 T1 Board drillings for connectors with right angled pcb contacts Identification Drawing Male connector* 25W3 27W2 36W4 * When using a female connector with right angled pcb contacts the board drilling pattern must be mirrored in ...

Page 40

... D-Sub HARTING customer request form for pcb connectors 1 Connector gender and type 2 Contact arrangement Standard Special configurations (mixed contact genders) 2.1 Any signal contacts? 2.2 Any power contacts? Current rating Termination type Performance level [mating side / termination side] 2.3 Any coaxial contacts? ...

Page 41

... D-Sub HARTING customer request form for pcb connectors 3 Pcb mounting accessories 3.1 Right angled version 3.2 Straight version 4 Additional information Pcb thickness: Operating temperature: Is hot plugging required Is a vacuum pick and place process considered? Is blind mating feature required? Name: Company: Address: ...

Page 42

... D-Sub HARTING customer request form for cable connectors 1 Connector gender 2 Contact arrangement Standard Special configurations (mixed contact genders) 2.1 Any signal contacts? Termination type Signal cable size for crimp contact Crimp contact performance level 2.2 Any power contacts? Current rating Termination type ...

Page 43

... HARTING customer request form for cable connectors 2.4 Any high voltage contacts? 2.5 Any pneumatic contacts? Tube inner diameter / suitable compressed air tube 3 Cable accessories HARTING has a wide range of hoods including plastic, metallized plastic and full metal versions. Name: Company: Address: Phone: Fax: E-Mail: ■ ...

Page 44

Notes ...

Related keywords