TERM BLK MOD FUSE 26-10AWG BLACK

3046032

Manufacturer Part Number
3046032
Description
TERM BLK MOD FUSE 26-10AWG BLACK
Manufacturer
Phoenix Contact
Series
CLIPLINE UTr
Type
Fusedr
Datasheets

Specifications of 3046032

Number Of Positions
2
Number Of Levels
1
Terminal - Width
6.2mm
Termination Style
Screw Clamp
Current - Iec
6.3A
Voltage - Iec
500V
Current - Ul
6.3A
Voltage - Ul
600V
Wire Gauge Or Range - Awg
10-26 AWG
Wire Gauge Or Range - Mm²
0.14-6mm²
Features
Fuse, 5mm x 20mm
Color
Black
Product
DIN Rail Terminal Blocks
Number Of Positions / Contacts
2
Wire Gauge Range
26-10
Current Rating
6.3 A
Voltage Rating
500 V
Flammability Rating
UL 94 V-0
Height
80.5 mm
Length
57.8 mm
Width
6.2 mm
Wire Gauge Max (awg)
10
Wire Gauge Min (awg)
26
Agency Approvals
cULus, CSA
Contamination Class
3
Current, Rating
6.3 A
Dimensions
6.2 mm x 56.8 mm
Fuse Type
Glass
Insulation Material
PA
Number Of Poles
2 Poles
Phoenix Part Number
UT 4-HESI(5X20)
Pin Spacing
6.2 mm
Primary Type
DIN Rail
Rated Surge Voltage
4 kV
Stripping Length
9 mm
Termination
Screw
Voltage, Rating
500 V
Wire, Awg
26-10
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
277-2034
UT 4-HESI (5X20)
http://eshop.phoenixcontact.de/phoenix/treeViewClick.do?UID=3046032
PHOENIX CONTACT Deutschland GmbH
http://www.phoenixcontact.de
Dimensions
Width
Length
Height NS 35/7,5
Height NS 35/15
Technical data
Fuse
Fuse type
Rated surge voltage
Pollution degree
Surge voltage category
Insulating material group
Connection in acc. with standard
Nominal current I
Nominal voltage U
Power loss
Connection data
Conductor cross section solid min.
Conductor cross section solid max.
Conductor cross section stranded min.
Conductor cross section stranded max.
Conductor cross section AWG/kcmil min.
Conductor cross section AWG/kcmil max
Conductor cross section stranded, with ferrule
without plastic sleeve min.
Conductor cross section stranded, with ferrule
without plastic sleeve max.
N
N
Order No.: 3046032
6.2 mm
57.8 mm
73 mm
80.5 mm
G / 5 x 20
Glass
6 kV
3
III
I
IEC 60947-7-3
6.3 A (if used as disconnect terminal block. With fuse, the current
is determined by the fuse used.)
500 V (if used as fuse terminal block)
500 V (if used as disconnect terminal block)
≥ 1.6 W (With single arrangement of the fuse terminal block in the
event of overload)
≥ 1.6 W (With interconnected arrangement of several fuse
terminal blocks in the event of overload)
≥ 4 W (With single arrangement of the fuse terminal block in the
event of a short-circuit)
≥ 2.5 W (With interconnected arrangement of several fuse
terminal blocks in the event of a short-circuit)
0.14 mm²
6 mm²
0.14 mm²
6 mm²
26
10
0.14 mm²
4 mm²