3G3JV-PFI1010-E Omron, 3G3JV-PFI1010-E Datasheet - Page 8

no-image

3G3JV-PFI1010-E

Manufacturer Part Number
3G3JV-PFI1010-E
Description
FILTER, 0.1-0.4KW, 1 PHASE MOTOR
Manufacturer
Omron
Datasheet

Specifications of 3G3JV-PFI1010-E

Filter Type
EMI
Current Rating
10A
Svhc
No SVHC (15-Dec-2010)
External Depth
45mm
External Length / Height
169mm
External Width
71mm
No. Of Phases
1
Power Rating
0.55kW
Termination Type
Wire
Capacitance
0µF
3G3JV inverter
Parameter
number
n017
n018
n019
n020
n021
n022
n023
n024
n025
n026
n027
n028
n029
n030
n031
n032
n033
n034
n035
n036
n037
n038
n039
20
Set of parameters (continued)
Default
setting
10.0s
10.0s
10.0s
0
0.00 Hz
0.00 Hz
0.00 Hz
0.00 Hz
0.00 Hz
0.00 Hz
0.00 Hz
0.00 Hz
6.00 Hz
100%
0
depending on
model
0
8min
0
2
5
3
6
MODBUS
address
111H
112H
113H
114H
115H
116H
117H
118H
119H
11AH
11BH
11CH
11DH
11EH
11FH
120H
121H
122H
123H
124H
125H
126H
127H
Name
Braking time 1
Acceleration time 2
Braking time 2
S curve slide on braking/
accelerating
Frequency reference value 1
Frequency reference value 2
Frequency reference value 3
Frequency reference value 4
Frequency reference value 5
Frequency reference value 6
Frequency reference value 7
Frequency reference value 8
Jog frequency
Max. reference value limit
Min. reference value limit
Motor rated current for simulation
of motor protection switch
Simulation of motor protection
switch
Thermal motor time constant
Function of ventilator
(in the inverter)
Multifunction input 2
Multifunction input 3
Multifunction input 4
Multifunction input 5
Adjustment range
0,0..999 s
0,0..999 s
0,0..999 s
0
1
2
3
0,0..400 Hz
0,0..400 Hz
0,0..400 Hz
0,0..400 Hz
0,0..400 Hz
0,0..400 Hz
0,0..400 Hz
0,0..400 Hz
0,0..400 Hz
0..110 % of n09
0..110 % of n09
0..120% in relation to inverter rated current
0
1
2
1 - - 60min
0
1
2
3
4
5
6
7
8
10 Jogging
11 Acc./dec. time change over
12 external base block (NO)
13 external base block (NC)
14 Speed search of max. frequency
15 Speed search of assigned frequency
16 Acc./dec. prohibit
17 Local/Remote change- -over
18 Serial change- -over/operator
19 Fast stop n19 error (NO)
20 Fast stop n19 alarm (NO)
21 Fast stop n19 error (NC)
22 Fast stop n19 alarm (NC)
0
see n036
34 Up or down comment
35 Self- -test otherwise see n036
no S curve
0,2 s
0,5 s
1,0 s
Standard motor with standard rated data
Standard motor for short- -time operation
No thermal protection
only runs during RUN (1 min after STOP)
always runs
reverse/stop (2- -wire)
external error (NO)
external error (NC)
Error reset
Multi- -step speed reference 1
Multi- -step speed reference 2
Multi- -step speed reference 3
Change in rotation direction (3- -wire) otherwise see n036

Related parts for 3G3JV-PFI1010-E