RPM7138-V4R Rohm Semiconductor, RPM7138-V4R Datasheet - Page 5

no-image

RPM7138-V4R

Manufacturer Part Number
RPM7138-V4R
Description
Infrared Receivers REMOTE CTRL 37.9KHZ
Manufacturer
Rohm Semiconductor
Datasheet

Specifications of RPM7138-V4R

Carrier Frequency
37.9 KHz
Transmission Distance
15 m
Viewing Angle
45 deg, 35 deg
High Level Pulse Width
800 us
Low Level Pulse Width
800 us
Minimum High Level Output Voltage
4.5 V
Output Current
2 mA
Operating Voltage
4.5 V to 5.5 V
Supply Current
0.95 mA
Maximum Operating Temperature
+ 75 C
Minimum Operating Temperature
- 10 C
Package / Case
RSIP-A3
Sensing Distance
15m
B.p.f. Center Frequency
37.9kHz
Voltage - Supply
4.2 V ~ 5.5 V
Current - Supply
1.5mA
Orientation
Side View
Mounting Type
Through Hole
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
RPM7138-V4R
Manufacturer:
ROHM/罗姆
Quantity:
20 000
Photo Link Module
Please use the receiver with shield case or shield plate as an EMI noise measures.
(Shield case and shield plate are required to be grounded.)
Because internal or external noise (CRT, fluorescent tube, motor, LCD backlight) of the receiver may cause malfunction
like a reduced effective distance.
(In the case of internal and external noise are strong, please use RPM7138-HxR series with holder.)
(1) All characteristics of the receiver in this specification are specified by supplying burst wave form (Fig.1) with ROHM
(2) When the receiver will be used as the wire-less remote controller, please use the signal method the signal format
(3) Please set up transmitter’s carrier frequency as same as the receiver’s f
(4) If transmission signal has non-continues carrier, error might be occurred. Continuous carrier is necessary.
(5) The receiver was designed to use as in-door use only.
(6) Noise environment (Light noise from inverter Lamp, and other kind of Lamps, Power ripple, electromagnetic noise from
(7) The receiver may not work properly if receiving signal judgment is done by single pulse due to the
(8) Emitting unit (remote control transmitter) has to be considered about its emitting device function, characteristics and
(9) Please connect ‘Holder’ on to the ‘Ground (GND)’ of PCB. If the holder is not connected to the GND, there is a
(10) Do not supply unnecessary stress to lead.
(11) Please pay careful attention to the lens.
(12) In order to prevent products from ESD, human body and solder iron, etc. are required to be grounded.
How to use the receiver without holder
Notes
If in case of other burst wave form will be used, please check these spec. Carefully under the evaluations.
which refer to “Measures to prevent malfunctioning of IR remote-controlled electric home appliances”. (Published July
1987 by Association of Electric Home Appliances)
If using other signal method, signal format, (ex: signal format which not including the leader signal) the receiver might
have chances to miss-function.
occurred.
Therefore, please understand that the receiver cannot cover all characteristics, in case of using it out-door.
power circuit, and etc) may cause a reduced effective distance.
surrounding / environmental noises.
To prevent such misjudgment, please make sure that the receiver is set up to work only when receiving
series of coded signal.
characteristics of the receiver.
possibility of worsening the characteristics of product.
It might have a chance to miss-function when the lens get dust or dirty. And also please do not touch the lens.
standard transmitter (Fig.2 ).
0
frequency. Otherwise error might be
T1
RPM7138-R series
T1≠T2
T2
Rev.B
5/7