OM13006,598 NXP Semiconductors, OM13006,598 Datasheet - Page 12

BOARD EVAL EM773 METER EU PLUG

OM13006,598

Manufacturer Part Number
OM13006,598
Description
BOARD EVAL EM773 METER EU PLUG
Manufacturer
NXP Semiconductors
Type
Other Power Managementr
Datasheets

Specifications of OM13006,598

Design Resources
Plug Meter Schematics, Gerber Files USB Dongle Schematics, Gerber Files
Main Purpose
Power Management, Energy/Power Meter
Embedded
Yes, MCU, 32-Bit
Utilized Ic / Part
EM773FHN33,551
Interface Type
USB
Maximum Operating Temperature
+ 150 C
Operating Supply Voltage
1.8 V to 3.6 V
Product
Power Management Development Tools
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Primary Attributes
-
Secondary Attributes
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
For Use With/related Products
EM773, OL2381
Other names
568-6681
NXP Semiconductors
EM773
Objective data sheet
7.10.1 Features
7.12.1 Features
7.11.1 Features
7.12 General purpose external event counter/timers
7.11 Metrology engine
The EM773 contains a metrology engine designed to collect voltage and current inputs to
calculate the active power, reactive power, apparent power and power factor of a load.
The purpose of the metrology engine is for non-billing applications such as plug meters,
smart appliances, industrial and consumer sub-meters, etc.
The EM773 includes two 32-bit counter/timers and one 16-bit counter/timers. The
counter/timer is designed to count cycles of the system derived clock. It can optionally
generate interrupts or perform other actions at specified timer values, based on four
match registers. Each counter/timer also includes one capture input to trap the timer value
when an input signal transitions, optionally generating an interrupt.
The I
I
Easy to configure as master, slave, or master/slave.
Programmable clocks allow versatile rate control.
Bidirectional data transfer between masters and slaves.
Multi-master bus (no central master).
Arbitration between simultaneously transmitting masters without corruption of serial
data on the bus.
Serial clock synchronization allows devices with different bit rates to communicate via
one serial bus.
Serial clock synchronization can be used as a handshake mechanism to suspend and
resume serial transfer.
The I
The I
1 % accurate for scalable input sources up to 230 V/50 Hz/16 A and
110 V/60 Hz/20 A while maintaining this accuracy with a factor of 1 to 400 down from
this maximum current.
Automatically calculates active power in W, reactive power in VAr, apparent power in
VA, power factor ratio, Vrms and Irms without ARM CPU intervention.
Standard API for initializing, starting, stopping and reading data from the metrology
engine using the ARM Cortex M0.
A 32-bit/16-bit timer/counter with a programmable 32-bit/16-bit prescaler.
Counter or timer operation.
One capture channel per timer, that can take a snapshot of the timer value when an
input signal transitions. A capture event may also generate an interrupt.
2
C-bus interface also supports Fast-mode Plus with bit rates up to 1 Mbit/s.
2
2
2
C-interface is a standard I
C-bus can be used for test and diagnostic purposes.
C-bus controller supports multiple address recognition and a bus monitor mode.
All information provided in this document is subject to legal disclaimers.
Rev. 1 — 1 September 2010
2
C-bus compliant interface with open-drain pins. The
Energy metering IC
© NXP B.V. 2010. All rights reserved.
EM773
12 of 45

Related parts for OM13006,598