MFRC52201HN1 NXP Semiconductors, MFRC52201HN1 Datasheet - Page 74

no-image

MFRC52201HN1

Manufacturer Part Number
MFRC52201HN1
Description
RFID Modules & Development Tools CL READER IC'S
Manufacturer
NXP Semiconductors
Datasheets

Specifications of MFRC52201HN1

Data Rate
3.4 Mbps
Operating Temperature Range
+ 85 C
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
MFRC52201HN1,157

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
MFRC52201HN1
Manufacturer:
NXP
Quantity:
500
Part Number:
MFRC52201HN1
Manufacturer:
NXP/恩智浦
Quantity:
20 000
NXP Semiconductors
112132
Product data sheet
18.3.1.7 Receive Command
18.3.1.8 Transceive Command
18.3.1.9 MFAuthent Command
The MFRC522activates the receiver path and waits for any data stream to be received.
The correct settings have to be chosen before starting this command.
This command terminates automatically when the received data stream ends. This is
indicated either by the end of frame pattern or by the length byte depending on the
selected framing and speed.
Remark: If the bit RxMultiple in the RxModeReg register is set to logic 1, the Receive
This circular command repeats transmitting data from the FIFO and receiving data from
the RF field continuously. The first action is transmitting and after a transmission the
command is changed to receive a data stream.
Each transmission process has to be started by setting bit StartSend in the register
BitFramingReg to logic 1. This command has to be cleared by software by writing any
command to register CommandReg e.g. the command idle.
Remark: If the bit RxMultiple in register RxModeReg is set to logic 1, this command will
This command handles the MIFARE
any MIFARE
command can be activated:
In total 12 bytes shall be written to the FIFO.
Remark: When the MFAuthent command is active, any FIFO access is blocked. Anyhow
Authentication command code (60h, 61h)
Block address
Sector key byte 0
Sector key byte 1
Sector key byte 2
Sector key byte 3
Sector key byte 4
Sector key byte 5
Card serial number byte 0
Card serial number byte 1
Card serial number byte 2
Card serial number byte 3
command does not terminate automatically. It has to be terminated by
activating any other command in the CommandReg register.
never leave the receiving state, because the receiving will not be cancelled
automatically.
if there is an access to the FIFO, the bit WrErr in the ErrorReg register is set.
®
classic card. The following data shall be written to the FIFO before the
Rev. 3.2 — 22 May 2007
®
authentication to enable a secure communication to
Contactless Reader IC
MFRC522
© NXP B.V. 2007. All rights reserved.
74 of 109