TISP4360M3BJR Bourns Inc., TISP4360M3BJR Datasheet - Page 14

Sidacs

TISP4360M3BJR

Manufacturer Part Number
TISP4360M3BJR
Description
Sidacs
Manufacturer
Bourns Inc.
Datasheet

Specifications of TISP4360M3BJR

Breakover Current Ibo Max
32 A
Rated Repetitive Off-state Voltage Vdrm
290 V
Off-state Leakage Current @ Vdrm Idrm
0.005 mA
Forward Voltage Drop
3 V
Mounting Style
SMD/SMT
Package / Case
DO-214AA
Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
TISP4360M3BJR-S
Manufacturer:
BOURNS
Quantity:
240 000
Part Number:
TISP4360M3BJR-S
Manufacturer:
TI
Quantity:
2 247
Fuses for the UL 1950/60950 power cross need to break the specified currents at 600 V a.c. - ordinary fuses will not do! Fuse specification
terms like
The requirement of Figure 14, box B, limits the fuse I
Box C, with its 1.3 A limit gives a flow division. Modems passing the TIA/EIA-IS-968 Type A surge in a non-operational mode, could use a fuse
of 1 A rating or less and satisfy the 1.3 A limit and move to box D. Modems operationally passing the Type A surge will tend to use a 1.25 A
fuse, such as the Bel SMP 1.25, and move to box F. Fuses with ratings of 2 A and above may not operate before the wiring simulator fails
(typically 3 A d.c.).
The TISP43xxMM conducts current for periods greater than the power cross test times, Figure 10, so the TISP43xxMM is not a major factor in
UL 1950/60950 compliance. The main design task for UL 1950/60950 power cross is about enclosure design and the selection of the other
components that are subject to power cross. A UL specified fuse together with a TISP43xxMM gives a simple design approach to meeting the
power cross requirements.
The TISP4350MM is designed to meet the FCC Part 68 Type B ringer voltages and is suitable for electro-mechanical hook switch POTS
modems, Figure 15. For ADSL modems, the TISP4360MM should be used as it has an increased working voltage to avoid clipping the ADSL
signal, Figure 16. The solid state hook switch used in POTS modems may be limited in voltage and dissipation capability. To reduce the
voltage stress level on the solid state switch, a 300 V V
Fuse Values for UL 1950/60950
TISP43xxMM and UL 1950/60950 Power Cross
Summary of TISP4350MM, TISP4360MM and TISP4300MM Applications
TISP43xxMMAJ/BJ Overvoltage Protector Series
short circuit capabilities to UL 1459 and UL 1950/60950, 40 A, 7 A and 2.2 A at 600 V a.c.
2
t to less than 100 A
(BO)
TISP4300MM can be used, Figure 17.
2
s.
Customers should verify actual device performance in their specific applications.
ensure that the 600 V breaking is met.
Specifications are subject to change without notice.
NOVEMBER 2001 - REVISED JANUARY 2007