70S2-04-D-05-V Magnecraft / Schneider Electric, 70S2-04-D-05-V Datasheet

no-image

70S2-04-D-05-V

Manufacturer Part Number
70S2-04-D-05-V
Description
Relay (Solid-State)
Manufacturer
Magnecraft / Schneider Electric
Datasheet
4/28
Advantages of the 70S2 Series
SECTION A - A'
Since acquiring this line of miniature
SSRs from Grayhill, this product has
continuously evolved both functionally
and visually. The 70S2 Series relays are
designed for medium-power loads. The
design incorporates a triac output for AC
loads and MOSFETs for DC loads. The
70S2 Series relays use optical isolation
to protect the control from transients. The
70S2 compact package is available in
a combination of screw, fast-on or PCB
terminals. Its compact size makes it ideal
for designs where space is limited. The
70S2 Series relays have excellent
thermal performance.
(57.7)
(43.2)
2.3
+
1.7
POWER SUPPLY
Small Packages
Eight Different Packages
Optically Isolated
Zero Cross Switching
Internal Snubber
Ideal for Tight Designs..
Wide Choice of Design
Options.
Input Isolated from Output.
Reduced Current Surges for
Most Loads.
Excellent Transient Protection.
INPUT
INPUT
(25.4)
1
A'
-
+
WIRING DIAGRAM
SSR
(44.9)
1.8
-
+
OUTPUT
(35.9)
1.4
- Switch up to 25
- Screw Terminals
- Panel Mount
Amps
LOAD
AC INPUT
- Switch up to 5 Amps
- Integrated Thermal
- PCB Mount
(57.5)
2.3
Management
- Switch up to 12 Amps
- Blade Terminals
- Panel Mount
70S2 V (3 Amp)
70S2 S
(24.3)
1
70S2 V (5 Amp)
M agne cr aft S olu tion Guide 1 0 5 A
Magnec r af t S olut ion G uide 1 0 5 A
70S2 N

Related parts for 70S2-04-D-05-V

70S2-04-D-05-V Summary of contents

Page 1

... Advantages of the 70S2 Series Since acquiring this line of miniature SSRs from Grayhill, this product has continuously evolved both functionally and visually. The 70S2 Series relays are designed for medium-power loads. The design incorporates a triac output for AC loads and MOSFETs for DC loads. The 70S2 Series relays use optical isolation to protect the control from transients ...

Page 2

... And this is just the beginning. We will continue to develop high value products - with innovative features not offered anywhere else in the industry. - Switch Amps - Solder Terminals - PCB/Panel Mount 70S2 M - Switch up to 2.5 Amps - Solder Terminals - PCB Mount 70S2 H - Switch Amps - Solder Terminals - PCB/Panel Mount 70S2 L 847-441-2540 4/29 ...

Page 3

... Series Solid State Relays/3, 5 Amp, V Style Input Terminals UL Recognized File No. E258297 General Specifications (@ 25° C) Output Characteristics Number and type of Contacts Switching Device Current Rating Switching voltage Switching Type Maximum Rate of Rise Off State Voltage (dv/dt) Min. Load current to maintain on Non-Repetitive Surge Current (1 cycle) Max ...

Page 4

... V (3 Amp) 70S2-05-B 70S2-04-C SPST-NO SPST-NO Triac Triac 24….140 AC 24….280 AC Zero Cross Zero Cross 300 300 300 1.6 AC 1.6 AC 400 AC 600 AC 6….32 DC 3…. 1….6 1…. 8.3 8.3 8.3 8.3 4000 AC 4000 AC 4000 AC 4000 AC UR, CSA UR, CSA -40… ...

Page 5

... Series Solid State Relays/3, 5 Amp, V Style continued Input Terminals UL Recognized File No. E258297 0.4 (10.2) 0.4 (10.2) 4/32 Printed Circuit Board Mounting 1.7 (43.2) 0.2 (5.7) IN 0.04 DIA. (1) 0.9 (22.9) 1.1 (27.9) Integrated Thermal Management Output Terminals 1 (26.4) OUT 0.3 (7.6) ...

Page 6

... V (3 Amp) Standard Part Numbers Input Voltage DC Operated Range 70S2-04-D-03-V 3….32 VDC 70S2-05-D-03-V 6….32 VDC 70S2-04-D-05-V 3….32 VDC 70S2-04-B-03-V 3….32 VDC 70S2-05-B-03-V 6….32 VDC 70S2-04-B-05-V 3….32 VDC 70S2-04-C-03-V 3….32 VDC 70S2-05-C-03-V 6….32 VDC 70S2-04-C-05-V 3….32 VDC 70S2-01-A-03-V 3….15 VDC 70S2-02-A-03-V 9… ...

Page 7

... Series Solid State Relays/N and S Style UL Recognized File No. E258297 Panel Mounting General Specifications (@ 25° C) Output Characteristics Number and type of Contacts Switching Device Current Rating Switching voltage Switching Type Maximum Rate of Rise Off State Voltage (dv/dt) Min. Load current to maintain on Non-Repetitive Surge Current (1 cycle) Max ...

Page 8

... AC 3…. 6…. 8.3 8.3 8.3 8.3 3000 AC 3000 AC UR, CSA -40…+125 -40…+100 (1.7) 1.0 1.0 847-441-2540 70S2 S 70S2-01-A 70S2-02-A SPST-NO SPST-NO MOSFET MOSFET 5 5 3….60 DC 3…. Switching DC Switching N/A N/A 100 100 7 (1 SEC SEC) 10 µ µ ...

Page 9

... Series Solid State Relays/N and S Style continued Input Terminals 0.5 (12.7) 0.25 (6.5) 0.2 (4.4) OUTPUT 0.9 1.2 MAX (22.9) (31.2) INPUT 0.4 (10.2) 0.187 (4.75) 1 MAX (26.2) 0.9 MAX (22.9) NOTE: MEASURE TERMINAL HEIGHT BY ZEROING 4/36 0.9 3-30 240 VAC (22 ...

Page 10

... Input Voltage 70S2 VDC, DC/DC RELAYS VDC, DC/DC RELAYS VDC PACK VDC (OR 32 VDC), DC/AC RELAYS VDC (OR 32 VDC), DC/AC RELAYS olu www.magnecraft.com 70S2 S BOLD-FACED PART NUMBERS ARE NORMALLY STOCKED Output Voltage Contact Switching Type Range Configuration 24….140 VAC SPST-NO 24… ...

Page 11

... Series Solid State Relays/F and M Style UL Recognized File No. E258297 Mounting General Specifications (@ 25° C) Output Characteristics Number and type of Contacts Switching Device Current Rating Switching voltage Switching Type Maximum Rate of Rise Off State Voltage (dv/dt) Min. Load current to maintain on Non-Repetitive Surge Current (1 cycle) Max ...

Page 12

... F 70S2-04-C SPST-NO Triac 24….280 AC Zero Cross 300 75 | 100 60 | 110 6 1.6 AC 600 AC 3…. 7…. 8.3 8.3 3000 AC 3000 AC UR, CSA -40…+125 -40…+100 4 35 (1.2) 1.0 Style M, 6 Amp olu www.magnecraft.com 70S2 M 70S2-05-C 70S2-01-A SPST-NO SPST-NO Triac MOSFET ...

Page 13

... Series Solid State Relays/F and M Style continued Mounting 0.4 (10.2) 0.2 (4.4) 0.3 (7.6) 0.3 (7.6) INPUT 1.2 MAX OUTPUT (31.2) 0.5 (11.4) 0.2 (5.1) 0.6 (15.2) 1 (26.2) 0.9 MAX (22.9) 4/40 Input Terminals Panel 1.2 (31.7) 0.2 (4.7) 0.03 (0.76) ...

Page 14

... SPST-NO 24….280 VAC SPST-NO 24….280 VAC SPST-NO 24….280 VAC SPST-NO – Output Voltage VDC 140 VAC 280 VAC VAC 847-441-2540 70S2 M Rated Current Switching Type Load (Amps) Zero Cross 4 Zero Cross 4 Zero Cross 4 Zero Cross 4 DC Switching 3 DC Switching ...

Page 15

... Series Solid State Relays/H and L Style UL Recognized File No. E258297 Mounting General Specifications (@ 25° C) Output Characteristics Number and type of Contacts Switching Device Current Rating Switching voltage Switching Type Maximum Rate of Rise Off State Voltage (dv/dt) Min. Load current to maintain on Non-Repetitive Surge Current (1 cycle) Max ...

Page 16

... AC 2500 AC 2500 AC 2500 AC UR, CSA UR, CSA -40…+125 -40…+125 -40…+100 -40…+100 3.5 3.5 22 (0.8) 22 (0.8) 1.0 1.0 847-441-2540 70S2 L 70S2-05-C SPST-NO Triac 2 24….280 AC Zero Cross 300 1.6 AC 400 AC 6…. 1…. 8.3 8.3 ...

Page 17

... Series Solid State Relays/H and L Style continued 1 (26.2) 0.5 (13.5) 0.3 (7.6) 1.2 (31.2) 0.2 (5.1) 0.6 (15.2) 4/44 Output Terminals Panel Mounting 0.2 (4.7) MIN 0.03 (0.76) 0.4 (10.2) 70S2 H 0.3 (7.6) 0.5 (11.4) 0.3 (7.6) 70S2 L 0.2 MIN. ...

Page 18

... H Standard Part Numbers Input Voltage DC Operated Range 70S2-04-D-02-H 3….30 VDC 70S2-05-D-02-H 6….30 VDC 70S2-04-B-02-H 3….30 VDC 70S2-05-B-02-H 6….30 VDC 70S2-04-C-02-H 3….30 VDC 70S2-05-C-02-H 6….30 VDC 70S2-04-B-06-L 3….30 VDC 70S2-05-B-06-L 6….30 VDC 70S2-04-C-06-L 3….30 VDC 70S2-05-C-06-L 6….30 VDC Part Number Builder – ...

Page 19

... Series Solid State Relays/K Style UL Recognized File No. E258297 General Specifications (@ 25° C) Output Characteristics Number and type of Contacts Switching Device Current Rating Switching voltage Switching Type Maximum Rate of Rise Off State Voltage (dv/dt) Min. Load current to maintain on Non-Repetitive Surge Current (1 cycle) Max ...

Page 20

... K Relay with the 70-459-1 Socket 70S2-04-D 70S2-05-B SPST-NO SPST-NO Triac Triac 4 4 8….50 AC 24….140 AC Zero Cross Zero Cross 300 300 1.6 1.6 200 AC 400 AC 3….30 DC 6…. 1….17 1…. 8.3 8.3 8.3 8.3 3000 AC 3000 AC 3000 AC ...

Page 21

... Series Solid State Relays/K Style continued 0.9 MAX (22.9) 0.187 (4.75) 4 PLACES 4/48 Socket Compatible Output Terminals 1.3 MAX 1.2 MAX (26.2) (31.2) 60VDC 3A 0.3 MIN. (7.1) OUTPUT 0.2 (5.9) 0.3 (7.2) 0.3 (7.1) Input Terminals - + 9-30 VDC - 0.02 (0.5) 4 PLACES 0 ...

Page 22

... K Relay with the 70-459-1 Socket Standard Part Numbers Input Voltage DC Operated Range 70S2-04-B-04-K 3….30 VDC 70S2-04-C-04-K 3….30 VDC 70S2-04-D-04-K 3….30 VDC 70S2-05-B-04-K 6….30 VDC 70S2-05-C-04-K 6….30 VDC 70S2-05-D-04-K 6….30 VDC 70S2-01-A-03-K 3….15 VDC 70S2-02-A-03-K 9….30 VDC Part Number Builder – ...

Related keywords