85100037 Crouzet USA, 85100037 Datasheet

no-image

85100037

Manufacturer Part Number
85100037
Description
SAFETY RLY, KNA3-XS 40-260VAC
Manufacturer
Crouzet USA
Series
KNA3-XSr
Datasheet

Specifications of 85100037

Relay Type
Safety
Contact Form
3PST (3 Form A)
Contact Rating (current)
6A
Switching Voltage
440VAC - Max
Coil Voltage
260VAC
Mounting Type
DIN Rail
Termination Style
Screw Terminal
Circuit
3PST (3 Form A)
Contact Rating @ Voltage
6A @ 250VAC
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Coil Type
-
Coil Current
-
Control On Voltage (max)
-
Control Off Voltage (min)
-
Lead Free Status / Rohs Status
 Details
11
"KNA3-XS" safety relay (22.5 mm)
Power supply
Power supply voltage
Operating range
On/off indication
Accuracy
Reset time
Maximum response time on
emergency stop
Output specification
Type
No. of safety circuits
No. of data circuits
Breaking capacity
Max. current breaking capacity
Max. voltage breaking capacity
Electrical life
Mechanical life
Operation and use
Max. absorbed power
On/off indication
Operating temperature
Storage temperature
Internal voltage
Dielectric strength
Resistance to tracking
EMC immunity according to EN 50082-2
Rapid transients
Radiated electromagnetic field
Electrostatic discharges
Shock waves
Radio frequencies in common
mode
Drop-out / short breaks /
microbreaks
* the device operates normally
** the device has not failed
dangerously
Casing
Material
Degree of protection
Terminal capacity
Weight
Technical characteristics
"Emergency stop" and "mobile guard monitoring"
functions
"CE" conforming product / BG approved
Control device with one or two channels
Safety via redundancy and self-checking
3 "N/O" safety contacts with linked contacts - 6 A / 250 a a
1 "N/C" signalling contact
Can be used to obtain level 3 according to NF.EN 954-1
a 24 V 50/60 Hz
c 24 V max. ripple 10%
-15% / +10% of Un for a
-15% / +15% of Un for c
1 power supply voltage LED
< 25 ms
< 50 ms
Volt-free outputs
3 “N/O" AgSnO
1 “N/C" AgSnO
1500 VA resistive
6.82 A
440 VAC
10
5.10
10
AC 1.6 VA / DC 2 W
1 internal relay status LED
0°C to +50°C acc. to IEC 68-2-14
-20°C to +70°C acc. to IEC 68-1/2
24 Vc
2.95 kV according to IEC 664-1
Material group III
2 kV directly acc. to IEC 1000.4.4
2 kV when coupled
10 V/m Level 3 acc. to IEC 1000.4.3
80 MHz to 1 GHz / 900 MHz
(ENV 50140/204)
8 kV in the air acc. to IEC 1000.4.2
Common mode 1 kV according to
IEC1000.4.5
10 V rms Level 3 according to
IEC 1000.4.6
150 kHz to 80 MHz (ENV 50141)
according to IEC 1000.4.11
Un-30% for 10 ms every 1 s
Un-60% for 100 ms every 1 s
according to IEC 61496-1/97
Un-100% for 10 ms every 100 ms*
Un-50% for 20 ms every 200 ms*
Un-50% for 500 ms every 5 s**
Polycarbonate
Self-extinguishing - UL94 class VO
Casing : IP40
Terminal : IP20
2 X 1.5 mm
2 X 2.5 mm
310 g
5
7
operations at 1500 VA resistive
operations
5
operations at 500 VA resistive
2
2
multicore with ferrule
solid conductor
2
2
contacts
contacts
11/6
*
Type
Part number
24 V a/c
40/260 V a
Conformity
European "Machinery" Directive 89/392/EEC
French Decree 92/765-766-768
European "Usage" Directive 89/655/EEC
French Decree 93-40 / 93-41
NF-EN 60204-1
NF-EN 292-1 and 2
NF-EN 954-1
NF-EN 418
NF-EN 1088
UL 508
C22-2 No. 14-M91
GS-ET-20
Connections
Key
A1-A2
Y1-Y2
13-14/23-24/33-34
41-42
Available 2nd half 1999
A1
A2
13
14
PWR
OUT
13 23 33 41
14 24 34 42
KNA3-XS
23
Y1
41
24
Y2
33
42
34
Standard products
(and voltage)
: Power supply
: Start / validation
: "N/O" safety contacts
: "N/C" signalling contacts
To order, specify :
Control device(s)
Example : KNA3-XS safety relay : 85 100 036
1
Part number
KNA3-XS
*
85 100 036
85 100 037
Category 3
UL
(C) UL
BG
1

Related parts for 85100037

85100037 Summary of contents

Page 1

BG approved Control device with one or two channels Safety via redundancy and self-checking 3 "N/O" safety contacts with linked contacts - 6 A ...

Page 2

... Depending on the degree of safety required, KNA3-XS can receive the following components as inputs : - emergency stop pushbuttons with one or two contacts (A1-A2) - position sensors (limit switches) with one or two contacts (A1-A2) - pushbutton for start or validation (Y1-Y2) A positive break operation device must be used if a single channel is used. (diagram 1) To increase the degree of safety, one " ...

Related keywords