HW1B-M1-B IDEC, HW1B-M1-B Datasheet

no-image

HW1B-M1-B

Manufacturer Part Number
HW1B-M1-B
Description
HW1B-M1-B HW Oper Assy Rnd Flsh Mom
Manufacturer
IDEC
Datasheet
500
IDEC’s HW switches are “The best engineered switch in the world” for a
reason. Carrying the CE mark, UL, CSA, CCC (Chinese), and TUV approvals, these
switches are designed for use in almost any part of the world.
Complete with finger-safe contact blocks offering IP20 protection, these 7/8”
(22mm) switches include illuminated and non-illuminated pushbuttons, pilot
Key features include:
Locking lever removable contact blocks
Finger-safe IP20 contacts as standard, other terminal
styles available
Tamperproof construction
All E-stops meet EN418 and are compliant with
SEMI S2 standards
Worldwide approvals
Easy to assemble
Choice of black plastic or metallic front bezels
Incandescent or LED illumination
Transformer or full voltage
Slow make double break self cleaning contacts
Rated Operational Characteristics
Maximum Inrush Current
Rated Insulation Voltage
Rated Switching Over-Voltage
Rated Impulse Withstanding Voltage
Rated Thermal Current
Minimum Switching Capacity
Electrical Reliability
Lamp Ratings
Contact Operation
Positive Action Operation
(Emergency Stops with NC contacts)
Operating Force
Recommended Terminal Torque
Applicable Wire Size
Contact Resistance
Contact Gap
Horsepower Rating
Contact Material
Operating Temperature
Vibration Resistance
Shock Resistance
Mechanical Life
File No. E68961
ø22mm - HW Series
HW Series — 22mm IEC Style Global Pushbuttons
File No. LR92374
®
HW: The Best Engineered Switch in the World
AC-15: A600 or Ue = 250V, le = 3A (NO, NC, NO-EM, NC-LB)
DC-13: P600 or Ue = 125V, le = 1.1A (NO, NC)
DC-13: Q600 or Ue = 125V, le = 0.9A (NO-EM, NC-LB)
40 A (40 ms)
600V
Less than 4kV, conforming to IEC60947-1
4kV for contact circuit, 2.5kV for lamp circuit
10 Amp
5 mA at 3V AC/DC
MTBF < 1 fault for 10 million operation cycles (3V DC, 5mA)
Incandescent: 1 W
LEDs: 6V/17mA max, 12V & 24V/11mA max, 120 & 240V/10mA max
Slow break NC or NO, self-cleaning
5.5mm to 10mm travel to latch, 45N minimum force to latch
10mm maximum travel, 1,800 operations per hour maximum for a Pushlock Turn Reset
900 operations per hour maximum for a Push-Pull
Flush and extended pushbuttons—with 1NO or 1NC contact: 6.2±2N (momentary), 7.0±2N (maintained)
Additional contacts—1NO or 1NC: +3.2N (momentary), + 3.3N (maintained)
0.8 N m (7.1 in lb.)
Minimum 1 x 22 AWG, max. 2 x 14 AWG or 1 x 12 AWG
Initial contact resistance of 50mΩ or less
4mm (NO and NC), 2mm (NO-EM and NC-LB)
Reference Value: 1/4 HP @ 120V (1ø non-reversing), 1HP @ 240V (3ø non-reversing)
Silver (gold plated contacts available - contact IDEC)
Operation: –25 to +50°C (without freezing), Storage: –40 to +70°C (without freezing)
10 to 55Hz, 98m/sec
980m/sec
Momentary pushbuttons: 5,000,000 (900 operations per hour), All other switches: 500,000
2
Registration No. R9551089 (E-stops)
Registration No. R50054316 (Dual Pushbuttons)
Registration No. J9650511 (Pilot Lights)
Registration No. J9551458 (all other switches)
Specifications
(100G) conforming to IEC6068-2-7
www.idec.com
2
(10G) conforming to IEC6068-2-6
lights, selector switches, and emergency stop switches.
All switches also incorporate mechanically keyed safety locking levers, ensuring
correct installation and maintaining safety in high-vibration applications.
Oiltight Switches & Pilot Devices
Certificate No.
2005010305145656

Related parts for HW1B-M1-B

HW1B-M1-B Summary of contents

Page 1

... Slow make double break self cleaning contacts IDEC’s HW switches are “The best engineered switch in the world” for a reason. Carrying the CE mark, UL, CSA, CCC (Chinese), and TUV approvals, these switches are designed for use in almost any part of the world. ...

Page 2

... Die stamped on the base LED Chip LED Chip LED Chip Protection Diode Protection Diode Protection Diode Zener Diode Zener Diode Zener Diode USA: 800-262-IDEC Canada: 888-317-IDEC ø22mm - HW Series Type HW-C/HW-F /HW-G 600V 10A AC-15 (A600) DC-13 (P600) 50V 110V 220V 440V 10A 10A ...

Page 3

... All assembled part numbers in catalog include standard, fingersafe (HW-F...) contacts. 6. Assembled units with spring-up terminals (HW-G...) can be ordered by removing an “F” from the part number (Ex. HW1B-M1F11-R becomes HW1B-M111-R). 7. Operator only models include operator plus button. 8. Additional contact configurations available ( total contacts). ...

Page 4

... Anti-Rotation Ring Appearance Part Number HW9Z-RL Use with notched panel cutout to prevent unit rotation. Operators Plastic Style Bezel Round Flush/ Extended HW1B-M0 HW4B-MO HW1B-A0 Safety Lever Lock Style Part Number HW9Z-LS USA: 800-262-IDEC Canada: 888-317-IDEC ø22mm - HW Series Button Colors B: Black G: Green ...

Page 5

... For contact assembly part numbers, see page 550. 6. All assembled part numbers in catalog include standard fingersafe (HW- F...) contacts. 7. Assembled units with spring-up terminals (HW-G...) can be ordered by removing an “F” from the part number (Ex. HW1B-M1F11-R becomes HW1B-M111-R). 8. Units with exposed screw terminals (HW-C...) must be ordered as sub- components. ...

Page 6

... HW1A-B3-j ø40mm Mushroom Cap HW1A-B4-j Metal Bezel 1. In place specify the Button Color Code from table. HW4B-MOL j Button Color Code Color Code Color Black B Blue HW4B-AOL Green G White Red R Yellow HW1B-M5 available only in black, red, green and yellow. – Code 505 ...

Page 7

... All assembled part numbers in catalog include standard fingersafe (HW-F...) contacts. 7. Assembled units with spring-up terminals (HW-G...) can be ordered by removing an “F” from the part number (Ex. HW2B-M1F11-R becomes HW1B-M111-R). 8. Units with exposed screw terminals (HW-C...) must be ordered as sub-components. 9. Operator only model includes operator and button. ...

Page 8

... Terminal (early make) (late break) Dummy TW-DB Block Contact Block Mounting Adaptor Style Part Number HW-CB2C 1. Used to mount contact blocks to operator. 2. IDEC strongly recommends using the safety lever lock to prevent heavy vibration or maintenance personnel from inadvertently unlocking contacts. Part Number Structure ...

Page 9

... All assembled part numbers in catalog include standard fingersafe (HW-F...) contacts. 9. Assembled units with spring-up terminals (HW-G...) can be ordered by removing an “F” from the part number (Ex. HW1B-M1F11-R becomes HW1B-M111-R). 10. Units with exposed screw terminals (HW-C...) must be ordered as sub-components. 11. Operator only models include operator and button. ...

Page 10

... Operator = Completed Unit Anti-Rotation Ring Appearance Part Number HW9Z-RL Use with notched panel cutout to prevent unit rotation. Plastic Metal red HW1B-V3R HW4B-V3R yellow HW1B-V3Y HW4B-V3Y red HW1B-V4R HW4B-V4R yellow HW1B-V4Y HW4B-V4Y HW1B-V4R-EMO-2 HW4B-V4R-EMO-2 HW1B-X4R HW4B-X4R HW1B-V5R – 509 ...

Page 11

... All HW series E-Stop switches comply with SEMI S2 standards. 13. All assembled part numbers in catalog include standard fingersafe (HW-F...) contacts. 14. Assembled units with spring-up terminals (HW-G...) can be ordered by removing an “F” from the part number (Ex. HW1B- M1F11-R becomes HW1B-M111-R). 15. Units with exposed screw terminals (HW-C...) must be ordered as sub-components. ...

Page 12

... Completed Unit Anti-Rotation Ring Appearance Part Number HW9Z-RL Use with notched panel cutout to prevent unit rotation. Operators Style Part Number ø40mm Head Plastic HW1B-Y2R Push-Pull Metal HW4B-Y2R Plastic HW1B-Y2Y Metal HW4B-Y2Y All E- Stop Buttons are not removable from the operator. 511 ...

Page 13

... FB1W-HW1B-V402R-EMO-2 1. Maximum of two contact blocks. 2. Box is supplied with yellow top and black bottom only. 512 E-Stop Stations 40mm Pushlock Turn Reset Plastic Bezel Metal Bezel FB1W-HW1B-V411R FB1W-HW4B-V411R FB1W-HW1B-V402R FB1W-HW4B-V402R 40mm Pushlock Key Reset Plastic Bezel Metal Bezel FB1W-HW1B-X411R FB1W-HW4B-X411R FB1W-HW1B-X402R ...

Page 14

... Current LED LSTDB-2 15mA 24V AC/DC ±10% Incandescent LSB-2 150mA Jumbo Dome Pilot Lights (Assembled) Actual Size * Part Number HW1A-P5 k HW9Z-PP5C k LSTDB-2 Power Lamp Rat- Consumption ings 0.36W – 3.6W 24V, 0.15A USA: 800-262-IDEC Canada: 888-317-IDEC ø22mm - HW Series Jumbo Dome 513 ...

Page 15

... HW1P-2FT8m-k – HW1P-2D2D-k m Lamp Type Code Code Lamp Code 6V Incandescent Blank 12V LED D 24V 120V 240V www.idec.com Oiltight Switches & Pilot Devices Dome Metal Bezel HW4P-2FQ0-k HW4P-2FQm-k-l HW4P-2FH2m-k HW4P-2FM4m-k HW4P-2FT8m-k – place of , specify the Lens/LED Color Code from table below place of specify the Full Voltage Code from table below ...

Page 16

... Round/ HW1A-P1-l Flush Dome HW1A-P2-l Square/ HW2A-P1-l Flush In place of l, specify the Lens Color Code. USA: 800-262-IDEC Canada: 888-317-IDEC ø22mm - HW Series Lamp Voltage (full voltage units only) 6V: 6V AC/DC Lens/LED Colors 12V: 12V AC/DC A: Amber 24V: 24V AC/DC G: Green 120V: 120V AC* ...

Page 17

... S 24V AC/DC White W 120V AC (LED only) Yellow Y 240V AC (LED only) Yellow LED not avail- able. Use white LED for yellow lens. www.idec.com Oiltight Switches & Pilot Devices Extended w/ Full Shroud Metal Bezel Plastic Bezel HW1L-MF2-k HW4L-MF2-k HW1L-MF2F10Qm-k-l HW4L-MF2F10Qm-k-l HW1L-MF2F01Qm-k-l HW4L-MF2F01Qm-k-l HW1L-MF2F11Qm-k-l ...

Page 18

... HW-DA1B 1. All assembled part numbers in catalog include standard fingersafe (HW-F...) contacts. 2. Assembled units with spring-up terminals (HW-G...) can be ordered by removing an “F” from the part number (Ex. HW1B-M1F11-R becomes HW1B-M111-R). HW-GA1 3. Units with exposed screw terminals (HW-C...) must be ordered as sub-components. Contact Block Mounting Adaptor ...

Page 19

... White W 120V AC (LED only) Yellow Y* 240V AC (LED only) 1. *40mm mushroom lenses not available in yellow. 2. Yellow LED not available. Use white LED for yellow lens. www.idec.com Oiltight Switches & Pilot Devices m Lamp Code Transformer Lamp Code Models Incandescent Blank Code Voltage Code ...

Page 20

... HW-DA1B 1. All assembled part numbers in catalog include standard fingersafe (HW-F...) contacts. 2. Assembled units with spring-up terminals (HW-G...) can be ordered by removing an “F” from the part number (Ex. HW1B-M1F11-R becomes HW1B-M111-R). HW-GA1 3. Units with exposed screw terminals (HW-C...) must be ordered as sub-components. Contact Block Mounting Adaptor ...

Page 21

... For nameplates, see page 546. 3. All assembled part numbers in catalog include standard fingersafe (HW-F...) contacts. 4. Assembled units with spring-up terminals (HW-G...) can be ordered by removing an “F” from the part number (Ex. HW1B- M1F11-R becomes HW1B-M111-R). 5. Units with exposed screw terminals (HW-C...) must be ordered as sub-components. ...

Page 22

... Block Contact Block Mounting Adaptor Style Part Number HW-CB2C 1. Used to mount contact blocks to operator (first pair only). 2. IDEC strongly recommends using the safety lever lock to prevent heavy vibration or maintenance personnel from inadvertently unlocking contacts. Safety Lever Lock Style Part Number HW9Z-LS ...

Page 23

... All assembled part numbers in catalog include standard fingersafe (HW-F...) contacts. 8. Assembled units with spring-up terminals (HW-G...) can be ordered by removing an “F” from the part number (Ex. HW1B-M1F11-R becomes HW1B-M111-R Units with exposed screw terminals (HW-C...) must be ordered as sub-components. 10. Standard color for knob and lever is black. ...

Page 24

... Block Contact Block Mounting Adaptor Style Part Number HW-CB2C 1. Used to mount contact blocks to operator (first pair only). 2. IDEC strongly recommends using the safety lever lock to prevent heavy vibration or maintenance personnel from inadver- tently unlocking contacts. Safety Lever Lock Style Part Number ...

Page 25

... All assembled part numbers in catalog include standard fingersafe (HW- F...) contacts. 7. Assembled units with spring-up terminals (HW-G...) can be ordered by removing an “F” from the part number (Ex. HW1B-M1F11-R becomes HW1B-M111-R). 8. Units with exposed screw terminals (HW-C...) must be ordered as sub- components. 9. Standard color for knob and lever is black. ...

Page 26

... Block Contact Block Mounting Adaptor Style Part Number HW-CB2C 1. Used to mount contact blocks to operator (first pair only). 2. IDEC strongly recommends using the safety lever lock to prevent heavy vibration or maintenance personnel from inadver- tently unlocking contacts. Safety Lever Lock Style Part Number ...

Page 27

... All assembled part numbers in catalog include standard fingersafe (HW-F...) contacts. 10. Assembled units with spring-up terminals (HW-G...) can be ordered by removing an “F” from the part number (Ex. HW1B-M1F11-R becomes HW1B-M111-R). 11. Units with exposed screw terminals (HW-C...) must be ordered as sub-components. 12. Additional contact configurations available ( total contacts). ...

Page 28

... Dummy TW-DB Block Contact Block Mounting Adaptor Style Part Number HW-CB2C 1. Used to mount contact blocks to opera- tor (first pair only). 2. IDEC strongly recommends using the safety lever lock to prevent heavy vibra- tion or maintenance personnel from inadvertently unlocking contacts. Part Number Structure ...

Page 29

... All assembled part numbers in catalog include standard fingersafe (HW-F...) contacts. 10. Assembled units with spring-up terminals (HW-G...) can be ordered by removing an “F” from the part number (Ex. HW1B-M1F11-R becomes HW1B-M111- R). 11. Units with exposed screw terminals (HW-C...) must be ordered as sub-components. 12. Additional contact configurations available ( total contacts) ...

Page 30

... Dummy TW-DB Block Contact Block Mounting Adaptor Style Part Number HW-CB2C 1. Used to mount contact blocks to opera- tor (first pair only). 2. IDEC strongly recommends using the safety lever lock to prevent heavy vibra- tion or maintenance personnel from inadvertently unlocking contacts. Part Number Structure ...

Page 31

... All assembled part numbers in catalog include standard fingersafe (HW-F...) contacts. 9. Assembled units with spring-up terminals (HW-G...) can be ordered by removing an “F” from the part number (Ex. HW1B-M1F11-R becomes HW1B-M111-R). 10. Units with exposed screw terminals (HW-C...) must be ordered as sub-components. 11. Yellow selector switch comes with white LED. ...

Page 32

... Contact Block Mounting Adaptor Style Part Number HW-GA1 TW-DA1FB HW-CBL TW-DA1B 1. Used to mount contact blocks to operator (first pair only). TW-F126B 2. IDEC strongly recommends TW-F246B using the safety lever lock to prevent heavy vibration or TW-F486B maintenance personnel from HW-T126 inadvertently unlocking contacts. HW-T246 HW-L486 ...

Page 33

... HWnF-3F04H2m-k HWnF-31F04H2m-k 240V HWnF-3F04M4m-k HWnF-31F04M4m-k 480V HWnF-3F04T8m-k HWnF-31F04T8m-k k Lens/LED Color terminals (HW-G...) can be ordered by removing an “F” from the part number Color Code (Ex. HW1B-M1F11-R becomes HW1B- Amber A M111-R). Green G (HW-C...) must be ordered as sub- components. Red R Blue S with white LED. White W available ( total contacts) ...

Page 34

... Contact Block Mounting Adaptor HW-GA1 Style Part Number TW-DA1FB HW-CBL TW-DA1B 1. Used to mount contact blocks to operator (first pair only). TW-F126B 2. IDEC strongly recommends TW-F246B using the safety lever lock to prevent heavy vibration or TW-F486B maintenance personnel from HW-T126 inadvertently unlocking contacts. HW-T246 HW-L486 ...

Page 35

... All assembled part numbers in catalog include standard (HW-F...) contacts. 2. Assembled units with spring-up terminals (HW-G...) can be ordered by removing an “F” from the part number (Ex. HW1B-M1F11-R becomes HW1B-M111-R). 3. Units with exposed screw terminals (HW-C...) must be ordered as sub-components. 4. Additional contact configurations available ( total contacts). ...

Page 36

... Block Contact Block Mounting Adaptor Style Part Number HW-CB2C 1. Used to mount contact blocks to operator (first pair only). 2. IDEC strongly recommends using the safety lever lock (included) to prevent heavy vibration or maintenance personnel from inadvertently unlocking contacts. Safety Lever Lock Style Part Number ...

Page 37

... HW-F10 0 1. All assembled part numbers in catalog include standard (HW-F...) contacts. 2. Assembled units with spring-up terminals (HW-G...) can be ordered by removing an “F” from the part number (Ex. HW1B- M1F11-R becomes HW1B-M111-R). 3. Units with exposed screw terminals (HW-C...) must be ordered as sub-components. 4. Additional contact configurations available ( total contacts). ...

Page 38

... Block Contact Block Mounting Adaptor Style Part Number HW-CB2C 1. Used to mount contact blocks to operator (first pair only). 2. IDEC strongly recommends using the safety lever lock (included) to prevent heavy vibration or maintenance personnel from inadvertently unlocking contacts. Safety Lever Lock Style Part Number ...

Page 39

... HW-F01 1. All assembled part numbers in catalog include standard (HW-F...) contacts. 2. Assembled units with spring-up terminals (HW-G...) can be ordered by removing an “F” from the part number (Ex. HW1B-M1F11-R becomes HW1B-M111-R). 3. Units with exposed screw terminals (HW-C...) must be ordered as sub- components. 4. Operator only models come with operator and button. ...

Page 40

... Contact Block Mounting Adaptor (safety lever lock included) Style Part Number HW-CB2C 1. Used to mount contact blocks to operator (first pair only). 2. IDEC strongly recommends using the safety lever lock (included) to prevent heavy vibration or maintenance personnel from inadvertently unlocking contacts. Part Number Structure H ...

Page 41

... HW7D-B22F1001-mn 1NO 1NO HW7D-B22F1010-mn 1NO-1NC 1NO-1NC HW7D-B22F1111-mn 2NO 2NC HW7D-B22F2002-mn 2NO 2NO HW7D-B22F2020-mn www.idec.com Oiltight Switches & Pilot Devices mButton Color nLegend Code Code GR: Green (top) Blank: Red (bottom) Without legend 1: WB: I/ON (top) White (top) O/OFF (bottom) Black (bottom) ...

Page 42

... Clear silicon rubber cover part number HW9Z-D7D. 3. All assembled part numbers in catalog include standard (HW-F...) contacts. 4. Assembled units with spring-up terminals (HW-G...) can be ordered by removing an “F” from the part number (Ex. HW1B-M1F11-R becomes HW1B-M111-R). 5. Units with exposed screw terminals (HW-C...) must be ordered as sub-components. kPilot Light Illumination l Pilot Lamp Color Code & ...

Page 43

... TW-F126B Non-illuminated TW-F246B TW-F486B Illuminated (with Pilot Light) 1. Used to mount contact blocks to operator (first pair only). 2. IDEC strongly recommends using the safety lever lock (included) to prevent heavy vibration or maintenance personnel from inadvertently unlocking contacts. Safety Lever Lock Style Part Number HW9Z-LS ...

Page 44

... Contact Block Top Button Bottom Button Type Normal Push Normal Push Dummy Dummy Dummy Dummy Dummy Dummy Dummy Dummy Dummy Dummy USA: 800-262-IDEC Canada: 888-317-IDEC ø22mm - HW Series Contact Block Mounting Position Example Mounting Position 4 Mounting Position 2 X Mounting Position 3 Mounting Position 543 ...

Page 45

... Top Button Bottom Button Type Normal Push Normal Push Dummy Dummy www.idec.com Oiltight Switches & Pilot Devices Contact Block Mounting Position Example Mounting Position 4 Mounting Position 2 Mounting Position 3 Mounting Position 1 ...

Page 46

... In place of j specify Button Color Code. 2. 130mm (5.1”) overall length. 3. 16mm flat base for easy alignment Rod Rod Appearance Part Number HW9Z-RS-TK2141 Operator Appearance Plastic Metal HW1B-MO HW4B-MO Contactor Reset Button j Button Color Code Color Code Color Black B White Green G ...

Page 47

... LEFT-RIGHT 209 OI (Int’l OFF ON) 250 LOWER-RAISE 210 MAN-AUTO 211 OFF-ON 212 ON-OFF 213 OPEN-CLOSE 214 RAISE-LOWER 215 www.idec.com Oiltight Switches & Pilot Devices HWAV–Yellow Plastic 45 1.6 0.9 22mm HWAV-O HWAV5-0† HWAV-27* HWAV5-27† 27 Selector Switches Legend Code AUTO-MAN-OFF ...

Page 48

... Oiltight Switches & Pilot Devices Copy this order form and use it to specify Letter Height, Custom Engravings, Location of Engraving on Nameplate, and Quantity Desired. To insure engraving accuracy, fax it to your IDEC representative or Distributor. Your Company: Name: Telephone: Fax & Email: HWAM Nameplate Step 1 ...

Page 49

... HW Series Copy this order form and use it to specify Letter Height, Maximum Number of Lines and Text to be engraved. To insure engraving accuracy, fax it to your IDEC representative or Distributor. Your Company: Name: Address: PO: Please check one of the boxes below to indicate your choice of engraving options: ...

Page 50

... Used to prevent contact mounting lever from moving due to heavy vibration or panel maintenance. 5” rod used with HW1B-M0. Provided with operator. Insert between bezel and locking ring. Plastic locking nut comes with all HW operators & assemblies. Used only with round or square flush pushbuttons. ...

Page 51

... For use with Illuminated Pushbuttons. Part Number Style HW-CBF10 HW-CBF01 HW-CBF11 HW-CBF20 HW-CBF02 HW-CBF22 Order lamp separately. HW-CB10 HW-CB01 HW-CB11 HW-CB20 HW-CB02 HW-CB22 www.idec.com Oiltight Switches & Pilot Devices Part Number HWLV-LENSR HW1A-P5j HW9Z-PP5C LSTDB- ( HW9Z-D7D HW-VG1 HW9Z-EMO-NP-TK2120 Applicable Part Numbers E-Stop Types Standards ...

Page 52

... Panel Thickness 0 50 blocks) 30 70.2 (4 blocks) Contact Block (Bottom View) 1 contact block 2 contact blocks 4 contact blocks USA: 800-262-IDEC Canada: 888-317-IDEC ø22mm - HW Series ø29mm Mushroom (HW1B-M3 -A3) M3.5 Terminal Screw Panel Thickness Locking Ring 0 29.4 50 blocks) 23.2 70.2 (4 blocks) Square Flush (HW2B-M1, -A1) M3 ...

Page 53

... Mushroom 13 23.2 Gasket Locking Ring 50 blocks ) 13 70 blocks ) 32 ø40mm Head EMO Pushlock Turn Reset (HW1B-V4) Locking Ring 50 blocks) 13 70.2 (4 blocks) ø60mm Head Pushlock Turn Reset (HW1B-V5) 29.4 15 34.5 www.idec.com Oiltight Switches & Pilot Devices Extended 29.4 29.4 Dimensions (mm) 29 ...

Page 54

... HW1E-BV4 HW1E-LV4 .2 (NC) .3 (NO) .1 (NC) .4 (NO) (1NO-1NC) Emergency Stop Stations A 76 HW1B-V4R Box Cover Mouting Screws Box Cover ø40mm Head Unibody Pushlock Turn Reset (HW1B-BV4) Panel Thickness 0 M3.5 Terminal Screw Terminal Cover Mounting Hole Unit HW1B-V3 HW1B-V4 14 HW1B-X4 32 HW1B-Y2 HW1B-V5 TOP ...

Page 55

... Contact Blocks Full Voltage Adapter M3.5 Terminal Screw Contact Block Locking Ring 65.8 (2 blocks) 2 contact blocks www.idec.com Oiltight Switches & Pilot Devices Dimensions (mm) Mounting Hole Layout Close mounting on 30mm centers Degree of protection: IP65 30 min. When mounting transformer or DC-DC converter type units on 30mm centers vertically and horizontally, keep the ambient temperature below 40º ...

Page 56

... Gasket Locking Ring 7 29 29.4 30.5 Transformer Model M.3.5 Terminal 7 29.4 Screw 21 USA: 800-262-IDEC Canada: 888-317-IDEC ø22mm - HW Series Dimensions (mm) X2 Locking Ring Dimensions (mm) Terminal Wiring Arrows indicate access directions for wiring. Contact Block Full Voltage Adaptor Tranformer 89 blocks ) 29.4 109 blocks ) 21 ...

Page 57

... Bottom Button 2 contact blocks 1 contact block Depth 89.4 mm 69.4 mm Transformer (480V) Transformer, DC-DC Converter 89.5 (2 contacts), 109.5 (4 contacts) 29.4 www.idec.com Oiltight Switches & Pilot Devices Dimensions (mm) Mounting Hole Layout R0.8 max. +0.2 ∗3 -The 3.2 mm recess is for preventing rota- tion and is not necessary when a nameplate or anti-rotation ring is not used ...

Page 58

... Safety Lever Lock Safety Lever Lock Screwdriver Contact Block Mounting Adapter HW9Z-KG2 TOP Marking TOP Marking Operator Panel Thickness: 1 HW9Z-KG4 USA: 800-262-IDEC Canada: 888-317-IDEC ø22mm - HW Series OR-55 Lamp/LED Removal Tool TOP 59 HW-VL1 Barrier 20 1.5 Remove Safety Lever Lock Lever Lock Operator Panel 36 ...

Page 59

... HW1S-3ST is identified by red plungers on the operator. 5. HW1S-3JT is identified by black plungers on the operator. www.idec.com Oiltight Switches & Pilot Devices Conforming to IED 947-5-1 Appendix C. Utilization categories AC-15 and DC-13. Operation rate: 1,800 op. hour Load factor: Inductive 0.4 ± 0.05 Resistive 0.9 ± 0.05 ...

Page 60

... Failure to tighten terminal screws may cause overheating and fire. HW General Instructions Safety Lever Lock IDEC strongly recommends using the safety lever lock (HW9Z-LS, yellow) to prevent heavy vibration or maintenance personnel from unlocking the contact assembly series can be mounted vertically with a minimum spacing but spacing should be determined to ensure easy operation (recommended minimum spacing: 100 mm) ...

Page 61

... Make sure that the seals are not twisted or tucked inside and that the gasket does not remain, otherwise the normal waterproof and dustproof characteristics are not ensured. 1. Remove the gasket. Barrier Remove Gasket Inside Inside www.idec.com Oiltight Switches & Pilot Devices maximum. (solid wire ø1.6mm maximum) One 2 2 5.5 min. 8 max Inside Inside 2 ...

Related keywords