SNDJ-CNT-G03 Honeywell Sensing and Control, SNDJ-CNT-G03 Datasheet - Page 2

ELECTRO

SNDJ-CNT-G03

Manufacturer Part Number
SNDJ-CNT-G03
Description
ELECTRO
Manufacturer
Honeywell Sensing and Control
Series
SNDJ-CNTr
Datasheet

Specifications of SNDJ-CNT-G03

Count Rate
35kHz
Number Of Digits/alpha
5
Input Type
Voltage
Output Type
4 ~ 20mA
Voltage - Supply
10 V ~ 36 V
Display Type
LCD Non-Backlit
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
480-2833
SNDJ-CNT Series
2
SPECIFICATIONS
Parameter
Measuring range
Accuracy
Analog output
Maximum open circuit voltage
Resolution
Maximum linearity error
Temperature drift
Set points/relay range
Hysteresis
Change over contact
Data I/O
Measuring/response time
Sensor input
Sensor supply
Sensor monitoring
Open collector output
Binary inputs
www.honeywell.com/sensing
• Input resistance: 30 kOhm
• Frequency range: (-3 dB): 0.01 Hz/35 kHz
• Trigger level: adaptive trigger level from 20 mV to 5 V or 500 mV to 5 V (factory configuration)
• Powered 2 and 3 wire sensors: min. and max. current consumption values are selectable in
• 0.5 mA to 25 mA. Sensors with consumption below Imin. or above Imax. will be signaled as
• Electromagnetic/VR sensors: Open circuit state of sensors. This supervision runs
• Both monitoring functions can be switched off via the configuration software
±100 ppm/degree K typ., ±300 ppm/degree K max.
See measuring range above
Serial EIA RS 232 interface with +5V-CMOS level 3-pole. 3,5 mm stereo headphone connector
Characteristic
Lowest: 0 Hz to 1,000 Hz
Highest: 0 Hz to 35 kHz
0.5% referred to the analog output end of range value.
G01/G03: current output 0 mA to 20 mA, resp. 4 mA to 20 mA
G02/G04: voltage output 0 V to 10 resp. 2 V to 10 V
Load G01: max 500 Ohm corresponding to a max. of 10 V
Load G02: min. load 7 kOhm corresponding to a max. of 1.4 mA
12 V
12 bit corresponding to 1:4096.
0.1 %
for each limit an upper and a lower set point may be set independently
max. 250 Vac, 1250 VA (dc: see operating instructions)
on the front side, common reference potential with negative pole of sensor supply
The min. measuring time (fix time) is programmable:
2/5/10/20/50/100/200/500 ms, 1/2/5 s
For input frequencies with a period SHORTER than the fix time:
For input frequencies with a period LONGER than the fix time:
Built-in sensor power supply: +14 V, max 35 mA, short-circuit proof built-in pull up
(+14 V) and pull-down (0 V) resistor 820 Ohm for connection of two-wire transmitters or daisy
chaining of CNTs
Galvanically separated output of sensor frequency.
For external selection between two sets (A/B) of programmable relay control and acknowledge
functions: (No external pull up needed) low active :U < +1.5 V high (open) :U > +3.5 V
peak depending on the amplitude of the input signal
the range
defective
permanently
Analog output
Analog output
• Max.: 2 tix time + max. period of the input frequency + 7.5 ms
• Typ.: fix time + 1 period of the input frequency + 7.5 ms
Relay
• Max.: 2 fix time + max. period of the input frequency + 10.5 ms
• Typ.: fix time + 1 period of the input frequency + 10.5 ms
• Max.: period of the input frequency + 7.5 ms
Relay
• Max.: period of the input frequency + 10.5 ms