D4NS-SK01 Omron, D4NS-SK01 Datasheet - Page 3

no-image

D4NS-SK01

Manufacturer Part Number
D4NS-SK01
Description
Safety Door Switch
Manufacturer
Omron
Series
D4NSr
Datasheet

Specifications of D4NS-SK01

Lead Free Status / Rohs Status
 Details
Configuration
Features
• Can be combined with the D4JL Guard Lock Safety-door Switch to prevent locked doors from being
• Even if an operator were to be trapped inside a hazardous area, the D4JL model with rear release
ANSI/RIA R15.06-1999 11.2.2 Interlocking portion
b) The interlocking portion of the interlocked barrier shall be installed, applied, and maintained so that:
8) Be capable of being easily unlocked from the inside of the safeguarded space with or without power available, when the possibility of full body
too easily opened.
button would allow the operator to unlock the door from the inside with the lever.
access exists;
Press the rear release
button to unlock the
Guard Lock
Safety-door Switch.
The door can be
opened from inside the
hazardous area by
using the inner lever.
Door inner side
Close door.
D4JL-SK40
Open door.
D4JL model
with rear release button (sold separately)
D4JL-SK40
Set the
disable-prevention
cover with a pad
lock to prevent an
operator from
disabling the open
condition.
Open door.
The handle-shaped fixture makes it easy
to use the Door Switch.
Application is
also possible on
doors
that
open to the left.
Door Opening
to the Left
D4NS-SK/D4JL-SK
For safety measures on large doors
that are potentially dangerous
because their movement cannot be
immediately stopped.
3