E3MC-X11 Omron, E3MC-X11 Datasheet

no-image

E3MC-X11

Manufacturer Part Number
E3MC-X11
Description
RGB FIBER OPTIC TYPE NPN OUTPT
Manufacturer
Omron
Series
-r
Datasheet

Specifications of E3MC-X11

Sensing Distance
20mm
Number Of Outputs
1
Output Type
NPN
Voltage - Supply
12 V ~ 24 V
Current - Supply
100mA
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
RGB Color Sensor Discriminates
Delicate Differences in Color.
Best Color Sensor in the Industry.
Ordering Information
Note:
Built-in
Amplifier
Type
Optical
Fiber Type
General-
purpose
Optical
Fiber Type
Built-in LED light source ensures long service life
and maintenance-free operation.
Discriminates differences in color without being
influenced by changes in ambient temperature,
brightness of sensing objects, or positioning of
sensing objects.
Models with built-in amplifiers for long-distance
sensing and those with fiber heads for tiny spot
sensing are available.
Incorporates easy-to-see detection level and
threshold level indicators.
Degree of protection to IP66 and easy to main-
tain.
4-color registration/4-output models are also
available.
RGB Color Sensor
RGB Color Sensor
Type
1. Refer to Specifications on page 3.
2. Eleven colors are discriminated at this distance. For a typical example, nine colors are discriminated at a sensing distance of 12
mm. Refer to page 6 for the definition of sensing distance.
E3MC-A11
E3MC-A41
E3MC-MA11
E3MC-MA41
E3MC-X11
E3MC-X41
E3MC-MX11
E3MC-MX41
E3MC-Y11
E3MC-Y41
E3MC-MY11
E3MC-MY41
Model
The shape of the
amplifier section is
the same as for the
E3MC-(M)A@@.
Appearance
E32-CC200
E32-T16
Sensing distance
Standard sensing distance
(See note 1)
200 mm
(See note 1)
5 mm
(See note 2)
12 mm
3 mm
Varies with
the recom-
mended fi-
ber.
diameter
Spot
1
4
1
4
1
4
outputs
No. of
E3MC
NPN
PNP
NPN
PNP
NPN
PNP
NPN
PNP
NPN
PNP
NPN
PNP
Output
1

Related parts for E3MC-X11

E3MC-X11 Summary of contents

Page 1

... Ordering Information RGB Color Sensor ■ Type Model Appearance Built-in E3MC-A11 Amplifier E3MC-A41 Type E3MC-MA11 E3MC-MA41 Optical E3MC-X11 Fiber Type E3MC-X41 E3MC-MX11 E3MC-MX41 The shape of the amplifier section is the same as for the E3MC-(M)A@@. General- E3MC-Y11 purpose E3MC-Y41 Optical E3MC-MY11 ...

Page 2

... Use E39- (Separately sold) Model Appearance Pattern positioning Discrimination of the color order of tissue paper boxes Sensor Mounting DIN-track Mounting Bracket Bracket When mounting the When mounting to the E3MC. (Can be inclined DIN track. to 15°) E39-L114 E39-L115 Green Yellow Black Red E3MC ...

Page 3

... Control output Load current: 100 mA max. NPN open collector output with a maximum residual voltage of 1.2 V for the E3MC-(M)A11, E3MC-(M)X11, and E3MC-(M)Y11. PNP open collector output with a maximum residual voltage of 2.0 V for the E3MC-(M)A41, E3MC-(M)X41, and E3MC-(M)Y41 ...

Page 4

... Mode C mode Response time Standard mode Tolerance (θ) 15° Detectable colors 11 standard colors 2. 1-output models only: E3MC-A@@/-X@@/-Y@@ 3. 4-output models only: E3MC-MA@@/-MX@@/-MY@@ 4. 0.75-mm double amplitude or 100 m 300 m/s when using a Mounting Bracket. 6. Refer to page 13 for Remote Teaching. Standard Sensing Objects ...

Page 5

... Detection level Angle (°) Note: 1. The E3MC-(M)Y@@ discriminates eleven colors at the above distances. For a typical example, nine colors are discriminated at a sensing distance of 12 mm. 2. The fiber to be inserted into the emitter is indicated with white lines. Insert the amplifier fiber into the lower emit- ter section ...

Page 6

... The following optical fibers are recommended for use with the E3MC-(M)Y@@. Model E32-TC200 E32-T11L E32-T16 E32-T17L Note: The E3MC-(M)Y@@ discriminates red, blue, and yellow films in stable operation at the above distances. E32-CC200 Sensing object: Blue/Green Distance X (mm) Sensing Objects: Red, Blue, and Yellow Films ...

Page 7

... E3MC Available Optical Fibers In addition to the previous recommended optical fibers, the following optical fibers are available for the E3MC-(M)Y@@. Refer to the E3X- NH Datasheet (E258-E1) for the following optical fibers in detail. Optical fibers other than the following are not available. Model ...

Page 8

... This mode ensures more delicate color discrimination than mode C. Response Time Selection (Note: Figures in parentheses are for the 4-output models ms): The E3MC can stably detect minute differences of color. Set the response time for usual applications ms): The E3MC will be in quick-response operation. Set the response time high-speed response is required ...

Page 9

... E3MC-@41 with PNP Output (1-output Models) Operation indicator (orange) 8-level detection indicator (green) 7-level threshold indicator 4-level bank (red) indicator (green) Main circuit E3MC-M@41 with PNP Output (4-output Models) Operation indicator (orange) 8-level detection indicator (green) 7-level threshold indicator 4-level bank (red) indicator (orange) Main circuit ...

Page 10

... As the detected color becomes closer to the registered color, the number of lit detection level indicators increase. The control out- put of the E3MC will the detection level exceeds the threshold level and OFF if the detection level does not exceed the threshold level provided that the E3MC is in conformity output mode ...

Page 11

... As the detected color becomes closer to the registered color, the number of lit detection level indicators increase. The control out- put of the E3MC will the detection level exceeds the threshold level and OFF if the detection level does not exceed the threshold level provided that the E3MC is in conformity output mode ...

Page 12

... Detection of Metal or Glossy Objects If the E3MC does not detect metal or glossy objects accurately, change the mounting angle of the E3MC so that it will not receive regular reflection light directly reflected from the objects. The mounting angle of the E3MC-(M)X@@ can be adjusted to approximately 10° with the mounting holes. ...

Page 13

... Apply power to the Sensor while pressing the SELECT DOWN button and TEACH button together. Checking Method Mode the E3MC will be displayed for 3 s after mode set- ting. When the mode selector is set to TEACH, the mode can be checked from the operation indicator. The indicator will be lit when the mode is set to B ...

Page 14

... Bank Sensing in bank 1. select- restarts. ing. Answer-back output with normal signal reception. The following is an example of ladder programming for setting control signals. Full control of the E3MC is possible using this function together with function 2. 00000 05000 T000 05001 T001 05002 05000 05002 END Note: 1. The permissible error of each signal pulse is ± ...

Page 15

... E3MC Dimensions Note: All units are in millimeters unless otherwise indicated. RGB Color Sensors ■ E3MC-A@@ E3MC-MA@@ Receiver Emitter E3MC-X@@ E3MC-MX@@ Sensing face (9.1 x 22.9) Receiver Emitter Sensing head (heat-resistive ABS) 3.3-dia. mounting holes Optical axis Mounting Dimensions (Fiber Head) Optical axis Four, M5 holes (depth: 5 ...

Page 16

... E3MC E3MC-Y@@ E3MC-MY@@ Receiver section Emitter section Accessories (Order Separately) (2-m Cord is Provided with the E3MC) ■ Sensor I/O Connector E39-C1 2M E39-C1 5M 8.8 dia. 10.5 dia. Sensor Mounting Bracket E39-L114 Six, R2.6 Material: Stainless steel (SUS430) 16 Fiber Unit mounting screw Two, 2.4 dia. ...

Page 17

... DIN-track Mounting Bracket E39-L115 Two, M3 Material: Stainless steel (SUS430) Installation Plug (Sensor I/O Connector) ■ E39-C1 2M E39-C1 5M Internal Wiring Note: Pin 8 is not used. When using the E3MC-@A Mounting Bracket Two, M3 Four, 5.5 dia. Connection Pin no. Wire color Lead wire color 1 White Output ...

Page 18

... Do not impose any voltage exceeding the rated voltage on the E3MC, otherwise the E3MC may be damaged. When supplying power to the E3MC, make sure that the polarity of the power is correct, otherwise the E3MC may be damaged. Do not short-circuit the load connected to the E3MC, otherwise the E3MC may be damaged. ...

Page 19

... The E3MC is ready to sense objects from 100 ms after the E3MC is turned ON, until when no devices connected the E3MC can be used. Be sure to turn ON the E3MC first if power is supplied to the E3MC and the load independently. When the E3MC is turned ON or OFF, the operation indicator will be ON for an instant but no control output will be turned ON ...

Page 20

... Tighten the M3 screw of the E39-L115 to secure the E39- L115. Removal Loosen the M3 screw of the E39-L115, press the E3MC in the direction indicated by arrow (5) and slide part A in the direction indicated by arrow (6). Then lift up the E3MC in the direction indi- cated by arrow (7) to remove the E3MC with the E39-L115. M3 screw (7) E3MC ...

Page 21

... Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. WARRANTY OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specifi ed) from date of sale by OMRON. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS ...

Related keywords