HMC1043-TR Honeywell Microelectronics & Precision Sensors, HMC1043-TR Datasheet - Page 6

MAGNETIC SENSORS

HMC1043-TR

Manufacturer Part Number
HMC1043-TR
Description
MAGNETIC SENSORS
Manufacturer
Honeywell Microelectronics & Precision Sensors
Type
Linearr
Datasheet

Specifications of HMC1043-TR

Sensing Range
±6g
Voltage - Supply
1.8 V ~ 10 V
Output Type
Differential Voltage
Features
Compass - Three Axis
Operating Temperature
-40°C ~ 125°C
Package / Case
16-LFQFN
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
For Use With
342-1066 - DEMONSTRATION BOARD FOR HMC1043
Current - Supply
-
Current - Output (max)
-
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Other names
342-1054-2
Honeywell
12001 Highway 55
Plymouth, MN 55441
Tel: 800-323-8295
www.honeywell.com/magneticsensors
HMC1043
A reset pulse is defined as a negative pulse current entering the S/R+ strap connection. The successful result would be
the magnetic domains aligned in a reverse easy-axis direction so that sensor bridge’s polarity is a negative slope with
positive fields on the sensitive axis result in negative voltages across the bridge output connections.
Typically a reset pulse is sent first, followed by a set pulse a few milliseconds later. By shoving the magnetic domains in
completely opposite directions, any prior magnetic disturbances will be completely erased by the duet of pulses. For
simpler circuits with less critical requirements for noise and accuracy, a single polarity pulse circuit may be employed (all
sets or all resets). With these uni-polar pulses, several pulses together become close in performance to a set/reset pulse
circuit. Figure 1 shows an H-Bridge Set/Reset circuit that will generate both set and reset pulses to the set/reset strap.
Additional information and examples on set/reset pulse circuits can be found in our application notes AN201 and AN213.
ORDERING INFORMATION
FIND OUT MORE
For more information on Honeywell’s Magnetic Sensors visit us online at www.magneticsensors.com or contact us at
800-323-8295 (763-954-2474 internationally).
The application circuits herein constitute typical usage and interface of Honeywell product. Honeywell does not warranty or assume liability of customer-
designed circuits derived from this description or depiction.
Honeywell reserves the right to make changes to improve reliability, function or design. Honeywell does not assume any liability arising out of the
application or use of any product or circuit described herein; neither does it convey any license under its patent rights nor the rights of others.
U.S. Patents 4,441,072, 4,533,872, 4,569,742, 4,681,812, 4,847,584 6,529,114 and 7,095,226 apply to the technology described
6
Ordering Number
HMC1043
HMC1043-TR
HMC1043-demo
Product
Cut Tape
Tape and Reel with 1k units/reel
Demonstration Board
Figure 1: Example H-Bridge Set/Reset Pulse Circuit From AN213
Form #900341 Rev F
November 2010
©2010 Honeywell International Inc.
www.honeywell.com